Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Most General Reasons for the Electrical Motor Failures
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Common > Most General Reasons for the Electrical Motor Failures

Most General Reasons for the Electrical Motor Failures

In this article, we will learn the most common general reasons for industrial electrical motor failures.

Last updated: October 15, 2022 2:56 pm
Viral Nagda
Common
No Comments
Share
4 Min Read
SHARE

In this article, we will learn the most common general reasons for industrial electrical motor failures.

Contents
Electrical Motor FailuresMotor Bearings FailureStator Winding FailureLow ResistanceContaminationRotor BarPower Availability

Electrical Motor Failures

Electrical Motor Failures

The motor is the most commonly used electrical equipment everywhere. Any application requires a motor to run a process.

So, obviously, the motor is one of the most running components in an electrical circuit. Due to this, there is a high chance of the motor going into failure mode.

Motor Bearings Failure

This is one of the most common reasons for motor failure. Motor bearing losses are huge and can damage the motor after a certain period of time.

Insufficient lubrication is one of the main causes of this. If you do not regularly re-grease your bearings at frequent intervals, then the bearing can fail.

Sometimes, people over-grease the bearings. Even this can overheat them and cause their failure. If you are using the wrong type of lubricant or grade of grease, then this may damage the bearings.

It is essential that the motor and load be correctly aligned under actual operating temperatures and conditions.

Sometimes, they may become misaligned due to deformation or thermal growth associated with temperature change.

This misalignment can also cause bearing failure. If the motor shaft is overloaded or if there is excessive vibration, then it can cause bearing failure.   

Stator Winding Failure

Overheating of the stator winding due to improper cooling conditions can result in its damage.

If you are starting and stopping the motor more frequently, then it can cause thermal stress on the windings, which will eventually result in overheating.

Even overloading can cause thermal stress on the windings.

Low Resistance

Another cause of motor failure is low resistance. Low resistance is caused by the degradation of the insulation of the windings due to conditions such as overheating, corrosion, or physical damage.

This leads to insufficient isolation between the conductors or motor windings, which can cause leakages and short circuits, and eventually motor failure.

Contamination

Contamination from dust, dirt, and chemicals is also one of the leading causes of motor failure.

Foreign bodies which find their way inside the motor can dent bearing raceways and balls, leading to high levels of vibration and wear.

The contamination can also block the cooling fan, limiting the motor’s ability to regulate its temperature, and increasing the likelihood of overheating.

Rotor Bar

As discussed before in the stator winding part, the same effect of overheating and overload, due to excessive start-stop, high load torque, and high inertia for a prolonged period of time can cause damage to the rotor windings.

Power Availability

If the quality of the power supply given to the motor is poor (transient voltage, voltage imbalance, and harmonic distortion), then the motor can get damaged easily after a prolonged period of time.

In this way, we understand the most general reasons which can cause a motor to fail.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Dew Point in Instrument Air
What is a Viscometer? – Types, Applications, Advantages
Next-Generation Security Surveillance Systems – AI Technology
Common Materials used in Instrumentation Cables
Beyond FR-4: Exploring Novel Materials for PCB Fabrication
Field Instrumentation Tips
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Automation in Farming & Agriculture
Applications of Robots in Various Fields
HVAC Water Chillers Principle
Basic Principles of Solar Technology
Pilot Valves and Pneumatic Amplifying Relays
Difference between Charge and Mass
Instrumentation documents
Difference Between Robotics and Automation

Keep Learning

Modern Instrumentation & IoT: Key Innovations & Trends

Modern Instrumentation & IoT: Key Innovations & Trends

PM of Instrument Air Compressor

PM of Instrument Air Compressor in Oil & Gas Plants

Comparison of Absorption Chillers and Electric (Compression) Chillers

Difference between HVAC Absorption Chillers and Electric Chillers

Pictorial Fluid Power Diagram

Hydraulic and Pneumatic P&ID Diagrams and Schematics

What is a Flange Gasket ?

What is a Flange Gasket ?

Instrumentation Loop Diagram

Loop diagram and System Inspection Lab Exercise

RJ45 Connector Pins

How to make RJ45 cable

The Role of CNC Machining in Electronics Manufacturing

The Role of CNC Machining in Electronics Manufacturing

Learn More

S7 1200 PLC Program

Siemens S7 1200 PLC configuration in TIA Portal

Centralized vs Decentralized Automation Systems

Centralized vs Decentralized Automation Systems

Scan cycle of a Siemens PLC

OB1 – Main Cyclic Organization Block in TIA Portal

Difference Between Adhesion and Cohesion

Difference Between Adhesion and Cohesion

RTD-standards

How to calculate the tolerance of a RTD sensor

100 Electronics and Electrical Projects for Engineering Students

100 Electronics and Electrical Projects for Engineering Students

PLC Ladder Diagram program

Contacts and Coils in PLC Ladder Logic

Power Electronics Objective Questions

Power Transistor Quiz

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?