Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: What LIC and FIC Controllers will do?
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Control Systems > What LIC and FIC Controllers will do?

What LIC and FIC Controllers will do?

Last updated: August 13, 2020 8:48 pm
Editorial Staff
Control Systems
No Comments
Share
2 Min Read
SHARE

In this example problem, we discuss about both LIC and FIC controllers and what will they do over time if the flow or level transmitter fails or if control valve not working in the loop.

Contents
What LIC and FIC Controllers will do?Question 1:Question 2:Answer 1:Answer 2:

This clearwell water level control system for a drinking water treatment facility maintains a constant level of water following filtration, for sourcing to customers:

What LIC and FIC Controllers will do?

LIC and FIC Controllers

Question 1:

Determine what both controllers (LIC and FIC) will do over time if the flow transmitter fails in such a way that it registers zero flow regardless of the actual flow rate of water through it.

Assume the level transmitter is direct-acting (i.e. greater signal with greater water level) and that the control valve is signal- to-open (fail closed).

Question 2:

Determine what both controllers (LIC and FIC) will do over time if the control valve fails in such a way that it ignores the controller’s output and opens wide.

Assume both transmitters are direct-acting (i.e. greater signal with greater flow ; greater signal with greater water level) and that the control valve is signal-to-open (fail closed).

Answer 1:

The flow controller (FIC) will send a “full-open” signal to the valve, because its transmitter indicates the flow rate is less than it should be.

The level controller’s output will saturate low, telling the flow controller to stop the flow as the clearwell level rises well above setpoint due to the uncontrolled flow coming in.

Answer 2:

The flow controller (FIC) will send a “close” signal to the valve, because its transmitter indicates the flow rate is excessive.

The level controller’s output will saturate low, telling the flow controller to stop the flow as the clearwell level rises well above setpoint due to the uncontrolled flow coming in.

Join the Discussion! Share your answers with us through below comments section.

Read Next:

  • Single Loop Controller
  • Over-Tuned PID Controller
  • Loop Tuning Tips
  • Types of Interlocks
  • Liquid Level Control
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Process Dynamics and PID Controller Tuning
Why Offset in Proportional Controller ?
Sink or Source? Normally Open or Normally Closed?
Transmitters 4-20mA Current Failure Alarm Limits
Proportional Controller Principle
Pressure Control Loop Wiring Connections
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Centrifugal Compressor Start Permissive and Interlocks
Difference between DCS, PLC, and RTU ?
Energize to Safe Loop philosophy
Concept of Redundancy in Control Systems
Difference Between SCADA and HMI
What is a Network Connector? – Types of Connectors
How to Download PlantPAx Library?
How to Do Logic Checks During Plant Pre-Commissioning

Keep Learning

PID Tuning recommendations

PID Tuning Recommendations based on Process Dynamics

Manufacturing Execution System in Industrial Automation

Manufacturing Execution System (MES) in Industrial Automation

Maintenance Override Switch (MOS)

What is Maintenance Override Switch (MOS) ?

Variable Speed Control of Propulsion Motor for VSI and CSI type Frequency Converters

Speed Control of Ship Electrical Motor Propulsion

Industrial Networking Interview Questions

Industrial Networking and Wireless Interview Questions

Problem in Water Level Control System

Problem in Water Level Control System

How to troubleshoot the PLC Hardware faults

Hardware Troubleshooting Steps for PLC Automation Systems

Building Management System

Building Management System

Learn More

Battery Interview QuBattery Interview Question and Answersestion and Answers

Battery Terminology

Moving Magnet type Velocity Transducer

Moving Magnet Type Velocity Transducer

Definitions of Electrical Grounding

Definitions of Electrical Grounding

Voltage Regulator Circuit

Basics of Voltage Regulator

open vs closed loop

Open Loop and Closed Loop Animation

Ohm Meter Circuit

Ohm Meter

Two Hand Control Logic

Two Hand Control Logic using PLC

PLC Counter Example for Bank

PLC Program for Bank Counter Application

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?