Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: What is a Condensate Pot? How to Install it?
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Flow Measurement > What is a Condensate Pot? How to Install it?

What is a Condensate Pot? How to Install it?

The main use of a condensate pot is for maximizing the accuracy of differential pressure flow measurement on steam (or vapor) applications.

Last updated: November 2, 2023 1:10 pm
Editorial Staff
Flow Measurement
4 Comments
Share
4 Min Read
SHARE

The main use of a condensate pot is for maximizing the accuracy of differential pressure flow measurement on steam (or vapor) applications.

Contents
Condensate PotHow to Install a Condensate Pot?Condensate Pot Applications

They are used to ensure that the condensation of steam in the impulse lines does not impair the ability to accurately sense differential pressure fluctuations and to minimize gauge line error because of differences between pairs of impulse lines.

Condensate Pot

Condensate Pot

The theory of operation for condensate pots is that between the process taping and the pot is a steam vapor. Between the pot and the differential pressure transmitter is water (liquid) which eliminates any measurement errors due to a liquid/vapor mix at the measurement device.

In order for this to work correctly, both high-pressure (HP) and low-pressure (LP) impulse lines should be the same length. Thus, eliminating pressure head errors. One condensate pot will be required for each impulse line.

How to Install a Condensate Pot?

Installation can be either vertical or horizontal lines between the primary (Flow Meter) and the secondary (transmitter/ gauge) to act as a barrier to the line fluid permitting direct sensing of the flow conditions.

These Units should be mounted at the same level minimizing possible errors that could arise due to unequal head of fluid in the connecting pressure lines.

How to Install a Condensate Pot

1. Evaluate the number of connections required on the condensate pot before ordering (inlets, outlets, fill port, drain port, gas vent port, etc)

2. Define condensate pot volume in liters and system pressure and temperature requirements.

3. Consider the need to trace heat and insulate all impulse lines.

4. Consider the need to add an anti-freeze media such as glycol to the water lines.

5. Keep vapor impulse lines as short as practicable.

6. Ensure both condensate pots are mounted at the same level. The higher connection point should be the reference. Consider both Vertical and horizontal steam pipelines.

7. The differential pressure measuring device (DP) should be mounted below both the condensate pots and the steam pipeline.

8. It is recommended that both impulse lines from the condensate pot to the DP include the facility for ‘blowdown’. Blowing down these lines periodically ensures that the collection of debris is prevented from impacting the measurement accuracy.

Condensate Pot Applications

The condensate pots also help us to trap any foreign material from the pipeline, preventing damage to the sensitive instrumentation components.

The condensate is drained from the bottom valve connection and is suitable for use with ball valves, which act as the drain port.

Source: Parker

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Types of Flow Devices
  • Coriolis Mass Transmitter
  • Paddle Wheel Flow Meter
  • Flow Nozzle Principle
  • Venturi Meter Animation
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Pitot Tube Working Principle
Importance of Flow Meter Turndown Ratio
Difference between Fixed Area & Variable Area FlowMeters
Prover Tank Calibration and Mass Flow Meter Verification Procedure
Advantages & Disadvantages of Different Flow Meters
Electro-Magnetic Flow meter Objective Questions
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
4 Comments
  • Stephen Morales says:
    April 6, 2021 at 12:06 am

    Thank you for the lesson.

    Reply
  • Rudolph Aguirre says:
    September 29, 2021 at 8:21 pm

    Is it a fact that condensate pots should not be insulated for their proper operation?

    Reply
    • Michael says:
      June 11, 2022 at 3:40 am

      Correct. You want the condensate pot uninsulated so the steam will condense to water in the condensate pot like it’s supposed to. If it is insulated, you are not allowing the heat to dissipate and therefore the steam remains steam and can affect your reading.

      Insulators are usually not aware of this requirement so they will insulate everything. On my last project, we had to go back and remove insulation on all of our steam line condensate pots.

      Reply
  • Arslan says:
    February 4, 2023 at 1:41 pm

    Hi, can I use condensate pot for the dp flow meter of gas service

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Turbine Flow Meter Installation Procedure
Multiphase Flow Meter Calibration Procedure
Comparison of Venturi and Orifice flow meter
What is a Vortex Flow Meter?
Orifice Plate Questions and Answers
What is a Flow Element? – Types, Comparison of Flow Elements
Flow Transmitter Rangeability
Types of Flow Meters MCQ – Instrumentation and Control

Keep Learning

Coriolis flow meters

What is a Coriolis Flow Meter?

flow Nozzle

Flow Nozzle Principle, Advantages, Disadvantages, Applications

Insertion flow meters

What is an Insertion Flow Meter? – Types, Principle, Advantages

Instrumentation Impulse Lines

All About Instrumentation Impulse Lines

Flow Transmitters Questions and Answers

Flow Transmitters Questions and Answers – Instruments Test

Flow Meter Reading Unstable

What Factors Affect the Stability of Flow Meter Readings?

Orifice Beta

Why is Orifice Beta in between 0.3 to 0.7?

Demystifying Reynolds Number

Why Viscosity is Not Included in the Orifice Equation?

Learn More

Rupture Disc

Working of Rupture Disk

Transmitter Detailed Specifications

Transmitter Detailed Specifications

Parts of PLC

Parts of PLC

Process Dynamics and PID Controller Tuning

Process Dynamics and PID Controller Tuning

Transistor Load Line Analysis

Transistor Load Line Analysis

Namur Digital Input Card

What is Namur Digital Input Card?

Basic DC Power Supply Circuit

Basic DC Power Supply Circuit

Technical Specification for Uninterrupted Power Supply (UPS) System

Technical Specification for Uninterrupted Power Supply (UPS) System

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?