Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: What is a Condensate Pot? How to Install it?
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Flow Measurement > What is a Condensate Pot? How to Install it?

What is a Condensate Pot? How to Install it?

The main use of a condensate pot is for maximizing the accuracy of differential pressure flow measurement on steam (or vapor) applications.

Last updated: November 2, 2023 1:10 pm
Editorial Staff
Flow Measurement
4 Comments
Share
4 Min Read
SHARE

The main use of a condensate pot is for maximizing the accuracy of differential pressure flow measurement on steam (or vapor) applications.

Contents
Condensate PotHow to Install a Condensate Pot?Condensate Pot Applications

They are used to ensure that the condensation of steam in the impulse lines does not impair the ability to accurately sense differential pressure fluctuations and to minimize gauge line error because of differences between pairs of impulse lines.

Condensate Pot

Condensate Pot

The theory of operation for condensate pots is that between the process taping and the pot is a steam vapor. Between the pot and the differential pressure transmitter is water (liquid) which eliminates any measurement errors due to a liquid/vapor mix at the measurement device.

In order for this to work correctly, both high-pressure (HP) and low-pressure (LP) impulse lines should be the same length. Thus, eliminating pressure head errors. One condensate pot will be required for each impulse line.

How to Install a Condensate Pot?

Installation can be either vertical or horizontal lines between the primary (Flow Meter) and the secondary (transmitter/ gauge) to act as a barrier to the line fluid permitting direct sensing of the flow conditions.

These Units should be mounted at the same level minimizing possible errors that could arise due to unequal head of fluid in the connecting pressure lines.

How to Install a Condensate Pot

1. Evaluate the number of connections required on the condensate pot before ordering (inlets, outlets, fill port, drain port, gas vent port, etc)

2. Define condensate pot volume in liters and system pressure and temperature requirements.

3. Consider the need to trace heat and insulate all impulse lines.

4. Consider the need to add an anti-freeze media such as glycol to the water lines.

5. Keep vapor impulse lines as short as practicable.

6. Ensure both condensate pots are mounted at the same level. The higher connection point should be the reference. Consider both Vertical and horizontal steam pipelines.

7. The differential pressure measuring device (DP) should be mounted below both the condensate pots and the steam pipeline.

8. It is recommended that both impulse lines from the condensate pot to the DP include the facility for ‘blowdown’. Blowing down these lines periodically ensures that the collection of debris is prevented from impacting the measurement accuracy.

Condensate Pot Applications

The condensate pots also help us to trap any foreign material from the pipeline, preventing damage to the sensitive instrumentation components.

The condensate is drained from the bottom valve connection and is suitable for use with ball valves, which act as the drain port.

Source: Parker

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Types of Flow Devices
  • Coriolis Mass Transmitter
  • Paddle Wheel Flow Meter
  • Flow Nozzle Principle
  • Venturi Meter Animation
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
Orifice Sizing Guidelines and Thumb Rules with Flowchart
Flow Transmitters Questions and Answers – Instruments Test
Venturi Flow Meter – Working Principle, Advantages, Animation
Bernoulli’s Principle and Equation – Flow Measurement
In-Line Flow Switch Working Principle and Animation
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
4 Comments
  • Stephen Morales says:
    April 6, 2021 at 12:06 am

    Thank you for the lesson.

    Reply
  • Rudolph Aguirre says:
    September 29, 2021 at 8:21 pm

    Is it a fact that condensate pots should not be insulated for their proper operation?

    Reply
    • Michael says:
      June 11, 2022 at 3:40 am

      Correct. You want the condensate pot uninsulated so the steam will condense to water in the condensate pot like it’s supposed to. If it is insulated, you are not allowing the heat to dissipate and therefore the steam remains steam and can affect your reading.

      Insulators are usually not aware of this requirement so they will insulate everything. On my last project, we had to go back and remove insulation on all of our steam line condensate pots.

      Reply
  • Arslan says:
    February 4, 2023 at 1:41 pm

    Hi, can I use condensate pot for the dp flow meter of gas service

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals
  • Vaishnavi on Free Instrumentation Course for Trainee Engineers

Related Articles

Pressure Temperature Compensation Flow Measurement

Pressure Temperature Compensation Flow Measurement

Open Channel Flow Measurement Animation

Open Channel Flow Measurement Principle

Turbine Flow Meter

All About Turbine Meters

positive displacement flow meter pictures

What is a Positive Displacement Flow Meter?

Sick Flow meters

Flare Ultrasonic Flow Meter – SOPAS Engineering Tool

Flow Meter Hook Up

Flow Meter Installation Guidelines

Flow Measurement Questions and Answers

80+ Flow Measurement Interview Questions and Answers

Coriolis flow meter sensor coils

Coriolis Flow Meter Construction

More Articles

PID parameters

PID in Siemens TIA Portal

Basic Principles of Solar Technology

Basic Principles of Solar Technology

Capacitively Coupled Multistage Transistor Amplifier

Capacitively Coupled Multistage Transistor Amplifier

Ball Float Steam Trap

Ball Float Steam Trap

calibrating low-pressure instrument

Simulate Different Values for Pressure Instrument Under Test

Locked Open (LO) and Locked Close (LC) Valves

Locked Open (LO) and Locked Closed (LC) Valves

Interposing Relay Panel (IRP)

Interposing Relay Panel (IRP) – Wiring and Testing Requirements

Calculate LRV and URV for 4-20 mA Loop-powered DP Transmitter

Calculate LRV and URV for 4-20 mA Loop-powered DP Transmitter

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!