Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Cut-outs between Platforms or Grating for Field Instruments
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Erection & Commissioning > Cut-outs between Platforms or Grating for Field Instruments

Cut-outs between Platforms or Grating for Field Instruments

Last updated: February 27, 2020 5:01 pm
Editorial Staff
Erection & Commissioning Instrumentation Design
No Comments
Share
2 Min Read
SHARE

Usually, Cut-outs between platforms or grating are not given due importance as they can be done on-site.

Contents
Platform or Grating for Field InstrumentsRead Next:

While we have such an approach, there is a concern that could go unnoticed.

This concern is regarding corrosion.

Let’s understand this by taking a practical example.

Platform or Grating for Field Instruments

Below is a Diagram of a Vacuum column with 2 platforms/ gratings.

Cut-outs between Platforms or Grating for Field Instruments

And we have placed a DP transmitter on platform/grating number 2, but HP tapping of transmitter is on grating/platform 1.

And we require cut-out for the same.

Usually, for corrosive environment, the materials that are specified are “Hot dip galvanized”.

So when you have fixed all the gratings etc on the tower and then decide to drill the cut-out then the edges get exposed.

These cannot be hot dip galvanized at this stage hence they are just painted.

Paint is temporary solution as compared to Hot dip galvanization.

Hence when the paint gets peeled of gradually along the edges, it would get corroded and would eventually turn into a safety hazard.

So in conclusion cut out of grating left to site personnel will have its edges painted which is not at par with being “hot dip galvanized” hence corrosion can gradually creep into it.

These corroded edges could cause injury to the site personal.

Hence prefer giving cut out during the manufacturing of this gratings so that the edges are also hot dip galvanized.

Thanks for reading.

Author: Asad Shaikh

Read Next:

  • Instrument Wrong Practice
  • Good and Bad Wiring
  • Positive Material Identification
  • How to Install Thermowell?
  • Instrument Hook Up Drawings
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
Explain Operation of the Lamp Circuit ?
How to Install Ultrasonic Level Transmitters
Safety Instrumented System Module Failure
Installation Precautions of Thermocouple and RTD
Design Logic Diagrams with Standard Formats for Process Control
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Solenoid Operated Valves and Latching Valves

Solenoid Operated Valves and Latching Valves

Design & Construction of Process Plant

Process Control Systems Philosophy Concept

heated instrument enclosures

What is Instrument Heated Enclosure or Protection Box?

Switch Contact checking with oscilloscope

What is Contact bounce ?

Instrumentation Books Free Download

Instrumentation Books Download

Basic Requirements of Sizing the Control Valves

Basic Requirements of Control Valves Sizing

Orifice Plate Sizing

Orifice Sizing Guidelines and Thumb Rules with Flowchart

Cable Tray Routing

Cable Routing

More Articles

GATE Instrumentation Questions and Answers

GATE Instrumentation Questions and Answers

Arc Protective Clothing

What is Arc Protective Clothing? – Importance, Features, Materials

Electricity and Magnetism Questions & Answers

Top 300 Electricity and Magnetism Questions & Answers

Electrical Machines Questions and Answers

Induction Generator Quiz

HVAC Multiple Choice Questions

HVAC Multiple Choice Questions

VPN for Control Engineers

How Important is VPN for Control Engineers?

PV Tracking in PID Controllers

What is PV Tracking ?

Pressure Measurement Objective Questions

Pressure Measurement Objective Questions

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?