Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Down Counter PLC Program
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > PLC Tutorials > Down Counter PLC Program

Down Counter PLC Program

Last updated: March 4, 2021 3:26 pm
Editorial Staff
PLC Tutorials
1 Comment
Share
4 Min Read
SHARE

To study the working of Up Counter PLC program in Allen Bradley Programmable Logic Controller (PLC).

Contents
Down CounterDown Counter Description Using PLC ProgramCounter Count Down Bit (C5:0/DN)Rung 0000Rung 0001Rung 0002Counter Count Down Bit (C5:0/CD):Rung 0000Rung 0001Rung 0000Counter Under Flow Bit (C5:0/UN):Conclusion:

Down Counter

Down Counter (CTD) Instruction

In the above picture, there are totally three parameter,

COUNTER: C4:0 – Counter File name (TimerC5:0, C5:1,C5:2…)

PRESET – PRE : Limit value of COUNT-Up to how much it should count

ACCUMULATOR – ACC : Running Value of counter when condition turn ON.

Down Counter Data File

From the data file,along with preset and accumulator, we have few more bits,

CD: Countdown Bit-whenever the counter is enable makes this bit to go ON.

DN: Done Bit-When accumulator value equals preset value, done bit turns to ON.

UA: Counter Underflow – When accumulator value reached the limit value (-32767),it rolls back to +32767 for the upcoming counter operation, underflow bit turns ON, in this condition.

Notes:

UA – Update Accumulator Value-Only used when high speed counters are used in the program.

CU & OV – Used for Up Counter Function.

Down Counter Description Using PLC Program

I:0/0 is used to give input to counter and Preset value and accumulator value set to 5.

Counter Count Down Bit (C5:0/DN)

In the below Ladder logic,

Rung 0000

Having condition input I:0/0 which gives input to counter to perform counter down function.

Rung 0001

Having Counter CU Bit which enable only when counter is in function or when input to the counter turns ON and accumulator value counted down.

Rung 0002

Counter done bit turns on when accumulator value equals preset value.

Counter Count Down Bit

Counter Count Down Bit (C5:0/CD):

In the below Ladder logic,

Rung 0000

Having condition input I:0/0 which gives input to counter to perform counter function.

Rung 0001

Having Counter CU Bit which enable only when counter is in function or when input to the counter turns ON and accumulator value counted down.

Down Counter PLC Programming

In the below Ladder logic,

Rung 0000

Having condition input I:0/0 which gives input to counter to perform counter function. Accumulator value goes to negative if I:0/0 goes ON for 6th time in the below case,

Down Counter Ladder Logic

Counter Under Flow Bit (C5:0/UN):

In the Below Ladder Logic,

Counter accumulator value under flows when accumulator value reaches -32767 in Allen Bradley PLC Programming.

plc counter programming examples

In the below ladder Logic,

When we turn ON the I:0/0 ,accumulator value rolls back to 32768 and start counting down from 32767 to -32767.Counter underflow bit turns ON when this condition happen (Rung 003).

How to Use Counters in PLC Programming

Conclusion:

We can use this explanation to understand the working of Down Counter function in Allen Bradley Programmable Logic Controller (PLC).

Author : Hema Sundaresan

If you liked this article, then please subscribe to our YouTube Channel for PLC and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

Industrial Control Systems

What is SCADA System ?

PLC Tanks Filling Logic

Move Instruction in PLC

PLC Hardware Parts

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
Difference Between Static and Temp Memory in Siemens PLC TIA Portal
Difference Between PLC and RTU?
Node-RED in PLC Industrial Automation
Scaling with Parameters (SCP) Instruction in PLC
PLC Program for Alarm Indication in Process Control
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
1 Comment
  • Toluwani says:
    October 1, 2021 at 12:18 am

    Hello Hema,
    Please, is there a way to hinder the countdown of the counter from reaching the negative count values without using a limits or comparison instructions?

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Ethernet IP Commissioning Tool software

How to Configure IP Address in Rockwell PLC?

PLC Problems Troubleshooting

PLC Problems Troubleshooting

Comparison of Control Loops - Open, Closed, Cascade, Feedforward, Ratio

Comparison of Control Loops – Open, Closed, Cascade, Feedforward, Ratio

VFD Commissioning and Testing Procedure

VFD Commissioning and Testing Procedure (Variable Frequency Drive)

PLC Conversion Program

How to use Converters in PLC

Interlock Philosophy

Types of Interlocks

How to troubleshoot the PLC Hardware faults

Hardware Troubleshooting Steps for PLC Automation Systems

Why Baud Rate is Important in Modbus Network

Why Baud Rate is Important in Modbus Network?

More Articles

On-OFF Valve Animation

What is ON/OFF Valve ?

Electrical Machines Questions and Answers

Synchronous Machines Power Angle Characteristics Questions

RF Level Sensors Principle

RF Level Switches Working Principle

PLC Ladder Logic Simulator Mobile Apps For Android

PLC Ladder Logic Simulator Mobile Apps For Android

Types of Industrial Relays

What is a Relay? Types of Industrial Relays

Fail-Close Valve

What is a Fail-Close Valve? – Advantages and Disadvantages

DC Circuits Multiple Choice Questions

DC Circuits Multiple Choice Questions

Digital Electronics Objective Questions

Digital Electronics Objective Questions – Set 9

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?