Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: PLC based Auto/Manual Operation of Roll down Shutters in Industry
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > PLC Tutorials > PLC based Auto/Manual Operation of Roll down Shutters in Industry

PLC based Auto/Manual Operation of Roll down Shutters in Industry

Last updated: March 4, 2021 3:56 pm
Editorial Staff
PLC Tutorials
No Comments
Share
4 Min Read
SHARE

This is PLC Program for the auto/manual operation of roll down shutters in industry.

Contents
PLC based Roll down Shutters OperationPLC SolutionList of Inputs/OutputsList of InputsList of OutputsLadder diagram auto/manual operation of roll down shuttersLadder Logic DescriptionNetwork 1 :-Network 2 :-Network 3 :-

PLC based Roll down Shutters Operation

PLC can be used to control the auto/manual shutter operation. Manual or automatic control operation can be selected via a selector switch. In automatic operation shutter operation is depended on the photo sensor. Write PLC program for the application using ladder diagram language.

PLC based Auto Manual Operation of Roll down Shutters

PLC Solution

Here consider two operation for the roll down shutter application. In manual operation shutter can be opened and closed by using manual switches (manual up and manual down).

For mode selection, we have considered here mode selection switch so It can be used to select mode (Auto and manual).

In automatic mode, mode selector switch should be ON. Here we have used photo sensitive switch for shutter up and down process. When day light is not detected shutter will be ON and if day light is detected shutter will be OFF.

Two limit switches are used for shutter up and down control.

List of Inputs/Outputs

List of Inputs

  • X0 :- Auto/manual switch
  • X1 :- Photo sensitive switch
  • X2 :- Shutter up limit switch
  • X3 :- Manual UP
  • X4 :- Shutter down limit switch
  • X5 :- Manual down

List of Outputs

  • Y0 :- Manual mode ON
  • Y1 :- Shutter UP
  • Y2 :- Shutter down

Ladder diagram auto/manual operation of roll down shutters

PLC Logic Auto Manual Operation of Shutters

Ladder Logic Description

Network 1 :-

Here mode selection logic is used. Mode selector switch (X0) should be ON for auto mode and it should be OFF for manual mode.

Network 2 :-

In auto mode shutter up output will be ON if auto mode selected and it will remain ON till shutter up limit switch is detected. In manual mode shutter up output will be ON when manual up is pressed and it will remain ON till shutter up limit is detected.

Network 3 :-

In auto mode shutter down output will be ON if auto mode selected and it will remain ON till shutter down limit switch is detected. In manual mode shutter down output will be ON when manual down is pressed and it will remain ON till shutter down limit is detected.

Note :- Above application may be different from actual application. This example is only for explanation purpose only. We can implement this logic in other PLC also. This is the simple roll down shutter control in industry using PLC, we can use this concept in other examples also.

All parameters and graphical representations considered in this example are for explanation purpose only, parameters or representation may be different in actual applications. Also all interlocks are not considered in the application.

Author : Bhavesh

If you liked this article, then please subscribe to our YouTube Channel for PLC and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

PID Controller Tuning

Limit Switch Working

PID Controller Modes

PLC Water Level Control

PLC Door Control System

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

PLC Automatic Irrigation System
Allen Bradley Math Functions
Difference Between CompactLogix and ControlLogix
Types of PLC
PLC Timer Programming Examples – TON, TOF, TP and TONR
PLC Panel and MCC Panel Interface Signals
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Preventive Maintenance of Variable Frequency Drive (VFD)
Modbus Communication between PLC and Energy Meter
1oo2 Evaluation Safety Instruction in Safety PLC
Why is RTO used in the Place of TON Timer?
Software Troubleshooting Errors and Faults in Siemens PLC
PLC Handbook
How to Create New Project Using Simatic Manager
How Modbus is used in Industrial Networks?
System Cabinet Health Checks – PLC and DCS Industrial Automation
Flexible Input Output Modules

Keep Learning

High-Speed Inputs in PLC

What are High-Speed Inputs in PLC?

PLC Documents

PLC System Documentation

OpenPLC - PLC Training for Students - Free Tutorials & Courses

OpenPLC – PLC Training for Students – Free Tutorials & Courses

Types of Interrupts Organization Blocks in Tia Portal

Types of Interrupt OB in Siemens Tia Portal

PLC Sizes and Applications

PLC Sizes and Applications

Demo of a SCADA Software – Level Control System

Augmented Reality and Virtual Reality in Industrial Automation

Augmented Reality and Virtual Reality in Industrial Automation

How to Create Faceplate in FactoryTalk View Studio

How to Create Faceplate in FactoryTalk View Studio?

Discover More

Nuclear Magnetic Resonance Spectrometer Questions and Answers

Continuous Wave NMR Spectroscopy Questions & Answers

Heat Exchanger Root Cause Analysis

Heat Exchanger Root Cause Analysis (RCA)

Auto-negotiation in Network

What is Auto-negotiation in Network?

Interview Questions on Battery Testing

Interview Questions on Battery Testing

Gases LEL and UEL

What is Lower Explosive Limit & Upper Explosive Limit ?

Magnetic Flowmeter vs. Turbine Flowmeter

Magnetic Flowmeter vs. Turbine Flowmeter – Comparison

Feedback Characteristics of Control Systems

Linearizing Effect & Regenerative Feedback MCQ

Hydrogen Sulfide Accident

The Aghorn Hydrogen Sulfide Accident – H2S Gas

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?