Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: What is an Insertion Flow Meter? – Types, Principle, Advantages
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Flow Measurement > What is an Insertion Flow Meter? – Types, Principle, Advantages

What is an Insertion Flow Meter? – Types, Principle, Advantages

A classic example of an insertion flow meter element is the Annubar, a form of averaging pitot tube. Learn the types and principles.

Last updated: November 2, 2023 6:59 am
Editorial Staff
Flow Measurement
No Comments
Share
5 Min Read
SHARE

When the pipe carrying process fluid is large in size, it may be impractical or cost-prohibitive to install a full-diameter flow meter to measure fluid flow rate.

Contents
Insertion Flow MeterAnnubarInsertion-type Turbine FlowmeterAdvantages of Insertion-type Instruments

A practical alternative for many applications is the installation of an insertion flow meter: a probe that may be inserted into or extracted from a pipe, to measure fluid velocity in one region of the pipe’s cross-sectional area (usually the center).

A classic example of an insertion flow meter element is the Annubar, a form of averaging pitot tube pioneered by the Dieterich Standard corporation. The Annubar flow element is inserted into a pipe carrying fluid where it generates a differential pressure for a pressure sensor to measure:

Insertion Flow Meter

Insertion flow meters

The Annubar element may be extracted from the pipe by loosening a “gland nut” and pulling the assembly out until the end passes through a hand ball valve.

Once the element has been extracted this far, the ball valve may be shut and the Annubar completely removed from the pipe:

Annubar

Annubar flow element

For safety reasons, a “stop” is usually built into the assembly to prevent someone from accidently pulling the element all the way out with the valve still open.

Other flowmeter technologies manufactured in insertion form include vortex, turbine, and thermal mass.

Insertion-type Turbine Flowmeter

An insertion-type turbine flowmeter appears in the following photographs:

insertion-type turbine flow meter

If the flow-detection element is compact rather than distributed (as is certainly the case with the turbine flow meter shown above), care must be taken to ensure correct positioning within the pipe. Since flow profiles are never completely flat, any insertion meter element will register a greater flow rate at the center of the pipe than near the walls.

Wherever the insertion element is placed in the pipe diameter, that placement must remain consistent through repeated extractions and re-insertions or else the effective calibration of the insertion flow meter will change every time it is removed and re-inserted into the pipe. Care must also be taken to insert the flow meter so the flow element points directly upstream, and not at an angle.

Advantages of Insertion-type Instruments

A unique advantage of insertion instruments is that they may be installed in an operating pipe by using specialized hot-tapping equipment.

A “hot tap” is a procedure whereby a safe penetration is made into a pipe while the pipe is carrying fluid under pressure.

The first step in a hot-tapping operation is to weld a “saddle tee” fitting on the side of the pipe:

insertion flow instruments

Next, a ball valve is bolted onto the saddle tee flange. This ball valve will be used to isolate the insertion instrument from the fluid pressure inside the pipe:

insertion flow instruments

A special hot-tapping drill is then bolted to the open end of the ball valve. This drill uses a high-pressure seal to contain fluid pressure inside the drill chamber as a motor spins the drill bit. The ball valve is opened, then the drill bit is advanced toward the pipe wall where it cuts a hole into the pipe.

Fluid pressure rushes into the empty chamber of the ball valve and hot-tapping drill as soon as the pipe wall is breached:

hot-tapping drill

Once the hole has been completely drilled, the bit is extracted and the ball valve shut to allow removal of the hot-tapping drill:

insertion flow meter installation

Now there is a flanged and isolated connection into the “hot” pipe, through which an insertion flowmeter (or other instrument/device) may be installed.

Hot-tapping is a technical skill, with many safety concerns specific to different process fluids, pipe types, and process applications. This brief introduction to the technique is not intended to be instructional, but merely informational.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Transit Time Flow Meter Advantages
  • Segmental Wedge Flow Meter
  • Piston Flow Meter Principle
  • Magnetic Flowmeter Quiz
  • Flow Measurement Questions
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
How Coriolis Mass Flow Meter Measure Density?
Difference between Different Types of Flow Meters
Transit Time Flow Meter Principle
What is a Velocity-based Flow Meter?
Laminar Flow Meter Working Principle
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals
  • Vaishnavi on Free Instrumentation Course for Trainee Engineers

Related Articles

Troubleshooting Magnetic Flow Meters Common Problems

Troubleshooting Magnetic Flow Meters Common Problems

What is Averaging Pitot Tube

What is an Averaging Pitot Tube? – Principle, Advantages

Vortex Flow Meters

All About Vortex Flow Meters

Flow Meter Hook Up

Flow Meter Installation Guidelines

Flow Meter Calibration Procedure

Flow Meter Calibration

wedge Flow meter

What is a Segmental Wedge Flow Meter?

Types of Flow Meters MCQ - Instrumentation and Control

Types of Flow Meters MCQ – Instrumentation and Control

Advantages and Disadvantages of Flow Measurement Techniques

Advantages & Disadvantages of Different Flow Meters

More Articles

TOC Analyzer Principle

Total Organic Carbon Analyzer Principle

Analyzers Questions and Answers

Amino-Acid Analyzers Questions & Answers

Bubbler Liquid Level Transmitter Calculation

Bubbler Liquid Level Transmitter Calculation

Statement List (STL) to Find Highest Value in the Data Block

Statement List (STL) to Find Highest Value

Pneumatic Relay

Pneumatic Relay Questions

MCQ on Measurement and Instrumentation

MCQ on Measurement and Instrumentation

PLC based Auto Manual Operation of Roll down Shutters

PLC based Auto/Manual Operation of Roll down Shutters in Industry

PLC Timer Program

PLC Timer Instructions

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?