Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Contact Vibration Measurement
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Vibration Measurement > Contact Vibration Measurement

Contact Vibration Measurement

Last updated: November 13, 2018 7:22 pm
Editorial Staff
Vibration Measurement
No Comments
Share
8 Min Read
SHARE

Types of Contact Vibration Measurement

Contents
Path MeasurementPotentiometric TransmitterLinear Variable Differential TransformerSpeed measurementPrinciple of electrodynamicsSeismometerAcceleration measurementPiezoelectric sensorPiezo-resistive sensorResistive sensorInductive sensor

Path Measurement

  • Potentiometer Type
  • LVDT Type

Speed Measurement

  • Electrodynamics
  • Seismometer

Acceleration measurement

  • Piezoelectric sensor
  • Piezo-resistive sensor
  • Resistive sensor
  • Inductive sensor

Path Measurement

Potentiometric Transmitter

The potentiometric transmitter is a one-dimensional position sensor. It is based on the potentiometer, an adjustable potential divider. A voltage is applied to a resistive track. A wiper runs along this resistive track and thus divides the resistor in two parts, as shown in figure (resistor R1 and R2).

At different positions of the wiper, specific resulting voltages can be measured, due to the change in resistance. The wiper moves because it is attached to the motion of the vibrating object. The frequency ranges from 5 Hz to 2 kHz, which corresponds to a possible maximum acceleration of 20 g. Potentiometric transmitters can achieve measuring strokes from 1 mm up to 2 m with an infinite resolution. The operating temperature ranges between double-digit temperatures below zero and 150 °C

Potentiometer Vibration Sensor

figure 1: Potentiometric transmitter (schematic)

Linear Variable Differential Transformer

The Linear Variable Differential Transformer (LVDT) is a kind of transformer which is based on induction. It can be used for relative measurement of the displacement. As shown in figure 2, this sensor works along one axis and it is possible to determine the direction of the motion. The LVDT basically consists of three coils and a core. The primary coil is connected to an AC supply for excitation.

The two other coils are placed on each side of the primary coil and are arranged series-opposed. In the center of this coil assembly is a core that influences the magnetic flux from the primary to the secondary coils. Depending on the motion of the core, which is attached to the vibrating object, direction and distance can be deduced from the output signal.

The carrier frequency range goes from 50 Hz to 25 kHz, which is typically defined as 10 times the frequency of the core motion. Using this setup, measuring displacements of more than ± 50 cm and an accuracy up to 0.1 μm μm is possible. The temperature range is between -270 °C and 600 °C

LVDT Principle

Figure 2: LVDT – Cutaway view with the primary coil A and the secondary coils B

Speed measurement

Principle of electrodynamics

The principle of electrodynamics is used in a relative speed sensor. It is based on the phenomenon of induction. In order to apply this principle a coil and a light permanent magnet is used. The magnet is fixed to the vibrating object. The magnet either moves contactless or it is guided within the coil.

Due to the movement of the magnet a voltage is induced in the coil. This voltage can be measured and it is directly proportional to the speed of the vibrations. The isolation of the wires is the only restriction for the maximum voltage. For example there are sensors with a working frequency range between 1 Hz and 2 kHz

Seismometer

Absolute speed can be measured with the Seismometer. The Seismometer consists of a seismic mass and a spring within a housing. Due to the inertia of the mass, there is a relative movement between the seismic mass and the housing, in case of vibrations. A coil, which is fixed to the housing, can be used cause induction.

Due to the movement of the mass, a voltage is induced in the coil. This voltage speed can be measured because it is proportional. Often attenuation equalization is installed in such a seismometer in order to avoid resonance peaks.

Seismometer

figure 3: Seismometer

In today’s seismometers the mass is fixed motionless in relation to the housing. Thus there is no voltage amplitude caused by motion of the seismic mass. However the force, that is needed to hold the mass in balance, is measured through voltage. Modern seismometers are able to register frequencies from less than 10-3 Hz up to 100 Hz. It is possible to detect movements in the range of about 1 nm and several centimetres. The principle of seismic mass can also be used in path and acceleration measurement.

Acceleration measurement

Piezoelectric sensor

 The piezoelectric sensor works on the basis of the seismic principle and the piezoelectric effect. Here quartz crystal and piezo ceramic replace the spring used in a Seismometer. The piezo material is fixed to the vibrating object on the one side and to the seismic mass on the other. Vibrations forces lead to strain and compression on the piezo material.
The piezoelectric effect describes the occurrence of an electric charge due to the change in length of the polarised materials. This charge is proportional to the acting force and can be tapped. Since the force is a product of mass and acceleration it can be easily computed. The piezo materials are very rigid, therefore damping might be necessary. This can be achieved by adding stoppers or immersing the parts in oil.
The weight of piezoelectric sensors varies from less than 1 g up to several grams. The linear frequency range of piezoelectric sensors varies from below 0.1 Hz up to 104 Hz. Thus, piezoelectric sensors allow measurements of accelerations under 1 g and up to several thousand g.
Piezoelectric vibration sensor
figure 4: Piezoelectric sensor

Piezo-resistive sensor

The piezo-resistive sensor uses four semiconductor strain gauges. These strain gauges are mounted on the vibrating object along with a seismic mass, using a bridge-circuit. Vibrations lead to a deformation of the strain gauges. During a motion in one direction two strain gauges are stretched and the other two are compressed, which results in voltage changes.
An advantage compared to the piezoelectric effect is the possibility of also measuring constant accelerations. It is possible to measure accelerations up to 1000 g. Piezoelectric sensors are more appropriate for high frequencies while semiconductor sensors are preferred at low frequencies.
Piezo-resistive vibration sensor
figure 5: Piezo-resistive sensor

Resistive sensor

The functional principle of the resistive sensor is the same as the one of the piezo-resistive sensor. The only difference is that the strain gauges are not built of materials that have a piezo effect. This leads to similar properties. But the measurable signal is lower.

Inductive sensor

The inductive sensor for acceleration measurement is based on the fact that the reaction force of the seismic mass can be converted into a path. Now the covered distance can be calculated through measuring the induced voltage and thus the magnitude and direction of the vibration can be ascertained. However this path-dependent measurement requires the sensor to be a lot bigger than comparable acceleration sensors.

Vibration Sensors Characteristics

Types of Vibration Sensors

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Recommended Articles

Why we use Negative Voltage in Vibration Measurement ?
Bently Nevada 3500 Machinery Protection Systems Hardware Modules
Speed Probe Working Principle
What is Keyphasor ? How does Keyphasor works ?
Vibration Monitoring System Step by Step Troubleshooting Guide
How to do calibration checks of vibration Probe, extension cable and vibration monitor
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • William Snyder on Top Non-PLC Certification Courses for Automation Professionals
  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Vibration Sensors Theory

How Vibration sensors Work ?

AND Logic in Bently Nevada Vibration System

AND Logic in Bently Nevada Vibration System

tk3 calibration instrument

What is TK-3 Calibrator ?

Turbine Supervisory Instrumentation

What is Turbine Supervisory Instrumentation (TSI)?

vibration probe mounting

Mechanical Vibration Switch Principle

Advantages and Disadvantages of Network Topology

Advantages & Disadvantages of Different Vibration Sensors

Vibration Measurement Questions

Interview Questions on Vibration Measurement

Seismic Transducers Objective Questions

Seismic Transducers Objective Questions

More Articles

Control Loop

What is a Control Loop ?

Economics of Power Generation Objective Questions

100+ Economics of Power Generation Objective Questions and Answers

Types of Industrial Storage Batteries

Types of Industrial Storage Batteries

Compile Project in Tia Portal

Communication between Wincc and Tia Portal

Sensors & Transducers Questions and Answers

Top 100 Sensors & Transducers Questions and Answers for Freshers

Difference Between Adhesion and Cohesion

Difference Between Adhesion and Cohesion

Forward Bias

Rectifiers, Forward Bias and Reverse Bias

Mechanical Vibration Switch

Vibration Switch Working Principle

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?