Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Capacitance Level Measurement Working Principle
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > How It Works > Capacitance Level Measurement Working Principle

Capacitance Level Measurement Working Principle

Last updated: September 14, 2016 5:47 pm
Editorial Staff
How It Works Level Measurement
No Comments
Share
5 Min Read
SHARE

Capacitance Level Measurement:

Capacitive level transducer is an example of indirect measurement of level

capacitance probe

Capacitance level sensors are used for wide variety of solids, aqueous and organic liquids, and slurries. The technique is frequently referred  as RF as radio frequency signals applied to the capacitance circuit. The sensors can be designed to sense material with dielectric constants as low as 1.1 (coke and fly ash) and as high as 88 (water) or more. Sludges and slurries such as dehydrated cake and sewage slurry (dielectric constant approx. 50) and liquid chemicals such as quicklime (dielectric constant approx. 90) can also be sensed. Dual-probe capacitance level sensors can also be used to sense the interface between two immiscible liquids with substantially different dielectric constants.

Since capacitance level sensors are electronic devices, phase modulation and the use of higher frequencies makes the sensor suitable for applications in which dielectric constants are similar.

Working Principle:

The principle of capacitive level measurement is based on change of capacitance. An insulated electrode acts as one plate of capacitor and the tank wall (or reference electrode in a non-metallic vessel) acts as the other plate. The capacitance depends on the fluid level. An empty tank has a lower capacitance while a filled tank has a higher capacitance.

 A simple capacitor consists of two electrode plate separated by a small thickness of an insulator such as solid, liquid, gas, or vacuum. This insulator is also called as dielectric.

Value of C depends on dielectric used, area of the plate and also distance between the plates.

capacitance equation

Where:

C = capacitance in picofarads (pF)

E = a constant known as the absolute permittivity of free space

K = relative dielectric constant of the insulating material

A = effective area of the conductors

d = distance between the conductors

This change in capacitance can be measured using AC bridge.

Measurement:

 Measurement is made by applying an RF signal between the conductive probe and the vessel wall.

The RF signal results in a very low current flow through the dielectric process material in the tank from the probe to the vessel wall. When the level in the tank drops, the dielectric constant drops causing  a drop in the capacitance reading and a minute drop in current flow.

This change is detected by the level switch’s internal circuitry and translated into a change in the relay state of the level switch in case of point level detection.

In the case of continuous level detectors, the output is not a relay state, but a scaled analog signal.

 Level Measurement can be divided into three categories:

  • Measurement of non-conductive material
  • Measurement of conductive material
  • Non-contact measurement

Non-conducting material:

For measuring level of non conducting liquids, bare probe arrangement is used as liquid resistance is sufficiently high to make it dielectric. Since the electrode and tank are fixed in place, the distance (d) is constant, capacitance is directly proportional to the level of the material  acting as dielectric.

Conducting Material:

In conducting liquids, the probe plates are insulated using thin coating of glass or plastic to avoid short circuiting. The conductive material acts as the ground plate of the capacitor.

Proximity measurements (Non-contact type measurements):

In Proximity level measurement is  the area of the capacitance plates is fixed, but distance between plates varies.

Proximity level measurement does not produce a linear output and are used when the level varies by several inches.

Advantages of Capacitive level measurement:

  1. Relatively inexpensive
  2. Versatile
  3. Reliable
  4. Requires minimal maintenance
  5. Contains no moving parts
  6. Easy to install and can be adapted easily for different size of vessels
  7. Good range of measurement, from few cm to about 100 m
  8. Rugged
  9. Simple to use
  10. Easy to clean
  11. Can be designed for high temperature and pressure applications.

 Applications:

Capacitance Level Probes are used for measuring level of

  1. Liquids
  2. Powered and granular solids
  3. Liquid metals at very high temperature
  4. Liquefied gases at very low temperature
  5. Corrosive materials like hydrofluoric acid
  6. Very high pressure industrial processes.

Disadvantages:

Light density materials under 20 lb/ft3 and materials with particle sizes exceeding 1/2 in. in diameter can be a problem due to their very low dielectric constants (caused by the large amount of air space between particles).

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

How Buoyant Force instruments Works ?
Open Tank Level Measurement using DP Transmitters Animation
Non-Contacting Radar Level Transmitter Working Principle
Displacer Level Measurement Calculations
Temperature Switch Working Principle
Level Transmitter Animation
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Paddle Wheel Flow Meters – Principle, Advantages, Limitations
Thermocouple Working Principle
DP Transmitter Dry Leg & Wet Leg Calculations
Flare Knockout Drums Working Animation
What is Dip Tape Level Measurement?
Boiler Drum Level Transmitter Calibration
Servo Operated Float Level Measurement
Gas Detectors Working Principle
Difference between Transparent Level Gauge and Reflex Level Gauge
Level Instruments Design Rules

Keep Learning

Beam-Detectors-Working-Principle-2

Beam Detectors Working Principle Animation

Tilt Level Switch Working Animation

The 5 ways Ultrasonic Sensors Work

The 5 ways Ultrasonic Sensors Work

Servo Level Transmitter Principle

Servo Level Transmitter Principle

ultrasonic-level-measurement

Ultrasonic Level Transmitter Working Principle

displacer level transmitter cylindrical weighs

Displacer Level Transmitter 5-point Calibration

Radiometric level Principle

Radiometric level measurement Working Principle

Paddle Wheel Level Switch Principle

Paddle Wheel Level Switch Principle

Discover More

Communicate between the PLC program and HMI program

Design a Program Using Studio 5000 and FactoryTalk View Studio

BP Refinery Explosion

Learnings from the BP Refinery Explosion at Texas City

Variable Air Volume Controller in HVAC

What is Variable Air Volume Controller in HVAC?

Difference between SR Flipflop and RS Flipflop

Difference between SR Flipflop and RS Flipflop ?

Inherent vs Installed Control Valve Flow Characteristics

Inherent vs Installed Control Valve Flow Characteristics

Digital Electronics Objective Questions

Digital Electronics Objective Questions – Set 7

Configure the Instruments in Flow Control Loop

Configure the Instruments in Flow Control Loop

Ion Analyzers Questions and Answers

Ammonia and Fluoride Electrode Questions & Answers

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?