Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Micro Memory Card (MMC) in Siemens PLC
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > PLC Tutorials > Micro Memory Card (MMC) in Siemens PLC

Micro Memory Card (MMC) in Siemens PLC

Last updated: March 4, 2021 11:27 am
Editorial Staff
PLC Tutorials
No Comments
Share
4 Min Read
SHARE

In this article, we will learn about Micro Memory Card (MMC), which is used in Siemens PLC.

Contents
Micro Memory Card in Siemens PLCS7 – 300 Siemens PLCTypesMMC and SD CardsCompact Flash (CF) Card

Micro Memory Card in Siemens PLC

Siemens micro memory card

MMC means micro memory card which looks the same as SD card but contains a very small amount of space (1 MB, 8 MB, etc.)

Although it looks the same in size and shape, you can’t use MMC in SD slot and reverse is also not possible.

MMC card is used to store the PLC program written by the user. Siemens s7-300 and 400 series of the CPU can not run without having an MMC card in it.

In the loss of a power supply, MMC keeps retaining data. Earlier Li-ion battery was used to hold the program in case of the power fail.

We know that the CPU contains four types of memory.

  1. Load memory
  2. Working memory
  3. System memory
  4. Retentive memory

In all four memory types, when a person downloads a program to the PLC, one part of the program automatically saved to retentive memory which is called MMC.

S7-1200 and 1500 CPU also require MMC card but it is not necessary to keep inserted MMC in this type of the CPU.

This type of PLC only requires an MMC or SD when you have to update a parameter or in case of diagnostic events.

This higher range CPU contains inbuilt memory which used to retain the program. So, this type of CPU can run without MMC.

S7 – 300 Siemens PLC

MMC Card in Siemens PLC

Types

In Siemens automation, both SD and MMC cards are used.

  • MMC cards are used with PLCs and
  • SD cards are used with the HMI.

MMC and SD Cards

The memory range for the MMC card is available from the lowest 64 kb to maximum up to 8 MB, whereas the SD card contain greater capacity of storage from 500 MB to a maximum of 2 TB.

You have to calculate the amount of space requires before choosing MMC.

It is always easy to recognize the memory card of the siemens. The green color card is always an MMC one and black is an SD card.

For example like s7-300 and 400 CPUs, remote I/Os, and VFD use green color MMC, whereas black color SD cards are used in s7-1200, 1500 CPUs, and HMIs.

Compact Flash (CF) Card

Apart from MMC and SD cards, there is one more type of card used in Siemens automation. Which recognize by its square shape and contains a higher capacity of the storage known as CF (compact flash).

Siemens Compact Flash (CF) Card

This type of card is used in motion control applications and HMIs.

Siemens MMC and SD cards play a very important role. For example, In the factory which produces the same type of machine/parts required to insert the program in it.

In such a scenario simply put a program in MMC and use the same program over and over by inserting MMC into CPU slot for about 5 to 10 seconds.

Author: Suhel Patel

If you liked this article, then please subscribe to our YouTube Channel for PLC and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Read-only Memory
  • Digital Logic Functions
  • Connect to Siemens S7 PLC
  • Non-mechanical Memory
  • Digital Memory Concepts
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Auto Sugar Bag Filling Station
Wood Sawing and Blower System: PLC Control Design
PLC Analog I/O Potential Problems – Troubleshooting & Issues
Traffic Light Control using PLC Ladder Logic
Test and Process Modes in Siemens PLC
Basic Concepts of the Safety Relay
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Create PLC Program based on Logic Circuit
Parking Lights PLC Program Explained with Video
PLC Program for Latching and unlatching Circuit
Overview of SIEMENS PLC – S7-1500, S7-1200, S7-400, S7-300
Types of Digital Outputs in PLC
How to Backup and Restore from Simatic Prosave HMI?
Evaluating Industrial Automation Projects Return on investment (ROI)
Siemens S7 300 CPU Status and LED Errors Explanation
PLC vs PAC – Understanding the Key Differences and Similarities
Connecting Blocks in Functional Block Diagram – Studio 5000

Keep Learning

Instrumentation Earthing

Instrumentation Earthing

PLC Program for Positive edge pulse output for one scan cycle

PLC Program for Positive Edge Pulse Output for One Scan Cycle

Allen Bradley PLC Example with Sub routines

How to use Sub Routines with Allen Bradley PLC

Turbine-Compressor System Architecture

Turbine-Compressor System Architecture

PLC Program for Automatic Door Control System

PLC Automatic Door Control System – Programming Example

HMI Simulation for PID Controller

PID Controller Output Types – PID_PWM and PID_Output

Types of PLC

#14 PLC Best Practices – Restrict Third-party Data Interfaces

Structured Text PLC Program for Measuring Event Duration

Structured Text PLC Program for Measuring Event Duration

Discover More

Industrial PLC Communication Network

Basics of Industrial Communication Networks

ESG in Industrial PLC Automation Systems

ESG in Industrial PLC Automation Systems

Siemens OB Blocks

Siemens PLC Organization Blocks (OB)

Latching and Unlatching in PLC Programming for Beginners

Latching and Unlatching in PLC Programming Example

Float-type Level Switch for Sensing Low Oil Level

Float-type Level Switch for Sensing Low Oil Level

Electric Circuits Objective Questions

Electric Circuits Objective Questions – Set 4

Control Valves Questions and Answers

Control Valve Questions and Answers

Basic Temperature Sensors MCQ

Basic Temperature Sensors MCQ Questions Answers

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?