Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Heat Exchanger Temperature Control
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Control Systems > Heat Exchanger Temperature Control

Heat Exchanger Temperature Control

Last updated: March 13, 2020 12:27 pm
Editorial Staff
Control Systems
1 Comment
Share
3 Min Read
SHARE

Since the outlet temperature of a heat exchanger can only change if there is an imbalance of inlet and outlet heat rates (assuming constant liquid inlet temperature and constant liquid composition), would this system be practical to achieve steady liquid outlet temperature control? Explain why or why not.

Heat Exchanger Temperature Control

Heat Exchanger Outlet Temperature Control

Note: the philosophy behind this control system is a principle known as energy balance, and it is a very valid principle. Explain what the principle of “energy balance” is, and how it is implied in the design of this control system.

Answer:

In theory, this feedforward system would work to hold the liquid outlet temperature absolutely constant, because it will try to maintain heat flow out equal to heat flow in (energy out balances energy in).

However, there are some practical reasons why it would not work (even if the liquid inlet temperature and composition were held constant).

Questions For You:

1. Explain why the control system as shown is impractical for real-life use, despite the fact that it does represent a very effective and important control strategy frequently used in industry.

2. Determine whether the controller needs to be direct acting or reverse acting.

3. A problem-solving technique useful for analyzing control systems is to mark the PV and SP inputs of all controllers with “+” and “−” symbols, rather than merely label each controller as “direct” or “reverse” action. Apply this technique to the control strategy shown here, identifying which controller input(s) should be labeled “+” and which controller input(s) should be labeled “−”.

4. Modify this control strategy to incorporate “feedback trim” in addition to the feedforward action it currently possesses.

5. Are there any loads unaccounted for in this feedforward control strategy? If so, see if you can modify this control strategy to account for them as well.

Join the Discussion! Share your answers with us through below comments section.

Read Next:

  • Valve Cascade Control
  • How to reduce Noise Signals
  • Compare SR and RS Flipflops
  • Wiring Diagrams of PLC and DCS
  • Ratio Control System
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Stroke Checking Procedure for GCV, SRV, IGV, and LFBV
Determine Voltage Drops at Respective Flow Rates in Loop Diagram
Switches, Repeaters, Bridges, Routers, Firewalls
Why Baud Rate is Important in Modbus Network?
Types of SCADA System Architecture
Square-Root in DCS or Flow Transmitter?
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
1 Comment
  • Jan Caspar Esguerra says:
    September 11, 2021 at 11:36 pm

    1. Yes, I am agreed that the control system is impractical for real-life use because TI must include the loop to measure the output disturbance of change of temperature.
    2. The output needed is Hot liquid so that FC will control FV where steam flow to be directing acting and reverse acting on the FV for the cold liquid in.

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

How to Stop Cyber Attacks on PLC or DCS?
What is Integral Wind Up ?
What is Ratio Control ?
Troubleshooting a 4-20mA Current loop
Troubleshooting Current Loops with Voltage Measurement
What is a Patch Panel? Types and Uses in Networking
How to Export Data from DeltaV System to Excel
PLC, DCS, and ESD Marshalling Cabinet Checks

Keep Learning

Closed Loop Control System

Types of Control Systems

Simple Loop with Local Indication

Instrument Loop Test Requirements and Operation Procedures

Hot Well Level Control System in Condensing Turbine

Hot Well Level Control System in Condensing Turbine

Rotary UPS or Dynamic UPS

What are Static UPS and Rotary UPS?

Difference Between Single Pair Ethernet and Traditional Ethernet

Difference Between Single Pair Ethernet and Traditional Ethernet

Process Shutdown

Difference between Process shutdown and Emergency Shutdown

Stripping tower unit

Process Control High Level Alarm Fault Analysis

Anti-static Wrist Straps

Anti-static Wrist Straps in Industrial Automation

Learn More

Armature Current in a DC Motor

DC Motor Torque

RAID stands for Redundant Array of Independent Disks

What is Raid Parity? – Types, Advantages, Disadvantages

Parallel Circuit Unknown Resistance

Simplified Formulas for Parallel Circuit Resistance Calculations

What is the consumed tag in Studio 5000 software?

Produced Tags and Consumed Tags in Studio 5000

State Variable Analysis and Design

Diagonalization

PISTON CHECK VALVE THEORY

Valve Materials Comparison Notes

Track PLC Operating Modes

#2 PLC Best Practices – Track Operating Modes

Calculate Power in Series RC Circuit

Calculate Power in Series RC Circuit

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?