Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: How to Convert Voltage to Current using Resistor ?
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > PLC Tutorials > How to Convert Voltage to Current using Resistor ?

How to Convert Voltage to Current using Resistor ?

Last updated: March 4, 2021 3:33 pm
Editorial Staff
PLC Tutorials
1 Comment
Share
2 Min Read
SHARE

In this article, we discuss about How to Convert Voltage to Current using Resistor with different examples like 0-10 VDC to 0-20 mA Conversion, 0-5 VDC to 0-20 mA Conversion.

Contents
Convert Voltage to CurrentExample : 0-10 VDC to 0-20 mA ConversionExample : 0-5 VDC to 0-20 mA ConversionNote:-

Convert Voltage to Current

It is extremely simple to measure 0-10Vdc signal with a device that will measure only Current inputs. If Current input module available will accept a 0-20mA signal, but may not accept a 0-10Vdc signal directly.

Basically, Ohms law is used to calculate a resistor value in order to convert the 0-10Vdc signal to a current.

How to Convert Voltage to Current using Resistor

Example : 0-10 VDC to 0-20 mA Conversion

Ohms law states: R = V/I where V is the Voltage, I is the current and R is the resistance 

R = 10V/0.020A = 500 Ohms

0-10 VDC to 0-20 mA Conversion
 I= V/R = 0/500   = 0mA
 
I= V/R = 10/500 = 0.02A = 20mA

Example : 0-5 VDC to 0-20 mA Conversion

Ohms law states: R = V/I where V is the Voltage, I is the current and R is the resistance 

R = 5V/0.020A = 250 Ohms

0-5 VDC to 0-20 mA Conversion
I= V/R = 0/250   = 0mA

I= V/R = 5/250 = 0.02A = 20mA

Note:-

  • To avoid damage you must ensure that the external current source has short-circuit protection in all conductor cases.
  • The external resistor is a source of error because of its dependency on temperature and its inaccuracy.
  • In order to obtain measuring results that are as precise as possible it is recommended to use resistors with tolerances that are as small as possible.

Credits : myplctechnology blog

If you liked this article, then please subscribe to our YouTube Channel for PLC and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • How to Connect a Solenoid Valve with PLC?
  • Redundant Power Supply for Critical Field Panels
  • How to Convert Current to Voltage using Resistor?
  • Gap Voltage of Bently Nevada Vibration Probe
  • Energy Conversion Quiz
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
Ferrules and Cross Ferruling
PLC Analog Signals Wiring Techniques
Allen Bradley Math Functions
PLC Ladder Logic Example based on Set Coil and Reset Coil
PLC Program for Star Delta Motor Starter
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
1 Comment
  • Chromium says:
    September 17, 2019 at 2:46 am

    You didn’t consider the internal resistance of the input.

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals
  • Vaishnavi on Free Instrumentation Course for Trainee Engineers

Related Articles

Master Control Reset (MCR) ladder logic

How to use Master Control Reset (MCR) Instruction in PLC

Electrical Circuit Breaker Quiz

100 Electrical Circuit Breaker Quiz

Delta WPL Soft Counter

Delta PLC Counter with Comparison

Programmable Logic Controller Quiz

Programmable Logic Controller Quiz

Search tank in Intouch Scada

Tank Filling and Emptying using Intouch Scada Script

PLC Program using Logic GATEs

PLC Logic GATE Program

How to program a running hours meter in PLC

Allen Bradley Studio 5000: Motor Running Hours PLC Program

Example Program Logic in Allen Bradley PLC

PLC Programming Examples on Industrial Automation

More Articles

Bottle’s Capping with Rotating Mechanism

PLC FBD Program for Bottle’s Capping with Rotating Mechanism

Magnatic Level Indicators Working Animation

Magnetic Level Indicators Working Animation

control of pneumatic systems

Control of Pneumatic Cylinder and Motor

what-is-o-ring

What is an O-Ring?

S84 - IEC 61511 Standard for Safety Instrumented Systems

S84 / IEC 61511 Standard for Safety Instrumented Systems

Parallel Circuit Unknown Resistance

Simplified Formulas for Parallel Circuit Resistance Calculations

Spectrometers Questions and Answers

Total Reflection Spectrometer Questions & Answers

Emergency Shutdown Button Installation (ESD)

Understanding Emergency Shutdown Button Installation (ESD)

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?