Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: AC Induction Motor Slip
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Electrical Theory > AC Induction Motor Slip

AC Induction Motor Slip

Last updated: August 6, 2018 1:41 pm
Editorial Staff
Electrical Theory
No Comments
Share
2 Min Read
SHARE

It is virtually impossible for the rotor of an AC induction motor to turn at the same speed as that of the rotating magnetic field. If the speed of the rotor were the same as that of the stator, no relative motion between them would exist, and there would be no induced EMF in the rotor. (Recall from earlier article that relative motion between a conductor and a magnetic field is needed to induce a current.) Without this induced EMF, there would be no interaction of fields to produce motion. The rotor must, therefore, rotate at some speed less than that of the stator if relative motion is to exist between the two.

The percentage difference between the speed of the rotor and the speed of the rotating magnetic field is called slip. The smaller the percentage, the closer the rotor speed is to the rotating magnetic field speed. Percent slip can be found by using below Equation.Motor Slip Formula

where

NS = synchronous speed (rpm)
NR = rotor speed (rpm)

The speed of the rotating magnetic field or synchronous speed of a motor can be found by using below Equation.

synchronous speed of a motor

where

NS = speed of rotating field (rpm)
f = frequency of rotor current (Hz)
P = total number of poles

Example:

A two pole, 60 Hz AC induction motor has a full load speed of 3554 rpm. What is the percent slip at full load?

Solution:

Synchronous speed:

synchronous speed of a motor

NS = (120 x 60 )/2

NS = 3600 rpm

Slip:

Motor Slip Formula

Slip = { (3600 – 3554) / 3600 } 100

Slip = 1.3 %

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Compound Generators
Resistivity
Calculate Power in Series RC Circuit
3-Wire, Three-Phase Delta Wiring System
Starting of DC Motors
Single Phase AC Induction Motors
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

AC Motor Theory
What is a circuit breaker ?
Rectifiers, Forward Bias and Reverse Bias
AC Generation Analysis : Effective Values, Phase Angle and Frequency
AC Generator Parts
Series and Parallel Inductors
Series Open Circuit Faults
Electrical Wiring Terminology

Keep Learning

Electric Short Circuit

Series Short Circuit Faults

Core-Type Transformer

Transformer Turns Ratio

Armature Current in a DC Motor

DC Motor Torque

Electrical Component Symbols

Electrical Diagrams and Schematics

Starting a Synchronous Motor

Starting a Synchronous Motor

Generator Action in a Motor

What is Synchroscope ?

AC Generator Nameplate Ratings

AC Generator Nameplate Ratings

Voltage and Current Phase Relationships in an Inductive Circuit

Voltage and Current Phase Relationships in an Inductive Circuit

Learn More

Classic Control Circuits

Motor Classic Control Circuits using Single Push button

Comparison of Half wave Rectifiers and Full wave Rectifiers

Comparison of Half wave Rectifiers and Full wave Rectifiers

Air Pressure Regulator cut-away diagram

Air Pressure Regulator Questions

Process Plant Risk and Safety Management

Safety Roles & Responsibilities of Process Engineering (Detail Design)

Contact less Tachometer

Types of Tachometers – Mechanical and Electrical Tachometers

safety PLC programming

SIS Logic Solver

Pause the Timer PLC Ladder Logic

Pause the Timer PLC Ladder Logic

actuated-valve-schematic

Components of Shutdown Valve

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?