Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Difference between HVAC Absorption Chillers and Electric Chillers
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Common > Difference between HVAC Absorption Chillers and Electric Chillers

Difference between HVAC Absorption Chillers and Electric Chillers

In this post, we will learn the difference between an absorption chiller and an electric chiller used in HVAC systems.

Last updated: September 28, 2022 4:16 pm
Viral Nagda
Common
No Comments
Share
5 Min Read
SHARE

In this post, we will learn the difference between an absorption chiller and an electric chiller used in HVAC systems.

Contents
What is a Vapour Compression Chiller?What is a Vapour Absorption Chiller?Difference between HVAC Absorption Chillers and Electric Chillers

HVAC is a very vast field and it comprises of many devices. One of the main components of HVAC is a chiller. A chiller is a refrigerant component that is used to cool the temperature of the water, air, or evaporation.

They are used in many commercial and industrial applications. Chillers are classified into various types.

One of them is classified based on a general working principle.

They are

  • Vapor Absorption Chiller
  • Vapor Compression Chiller (also called Electric Chiller)

In this post, we will see the difference between an absorption chiller and an electric chiller.

What is a Vapour Compression Chiller?

In this system, a compressor is used to compress the refrigerant gas. The gas is then pushed by the compressor and rotated in the whole circuit. This means that the vapor is compressed and then rotated in the whole system by the compressor. So, in this chiller, the compressor is an integral part.

Centrifugal water chillers use dynamic compression to convert kinetic energy to static energy. To increase the pressure and temperature of the refrigerant, the impeller blades draw the refrigerant in.

Once it has passed through the impeller, the refrigerant is at a higher pressure and in a condition that allows its heat to be rejected from the chiller.

What is a Vapour Absorption Chiller?

Unlike the previous one, this method does not use a compressor; but instead, it uses a heat source to move the refrigerant around the circuit. The heat source can be hot water or steam. The main components instead of the compressor are the absorber, pump, and generator.

What is a Vapour Absorption Chiller
Image Courtesy: LG

In an absorption chiller, the generator uses a high-temperature energy source, usually steam or hot water, which flows through the tubes and boils off the refrigerant into vapor.

The vapor moves to the condenser and the concentrated solution returns to the absorber. In the absorber, the refrigerant vapor is absorbed by the solution and condenses into a vapor, releasing the heat it acquired in the evaporator.

Difference between HVAC Absorption Chillers and Electric Chillers

The following are the key difference between the electric chiller and absorption chiller are mentioned below.

  • The first and the most general comparison is its technology in working. Electric (vapor compression) chillers use compression to push the refrigerant; whereas absorption chillers use the heat source to push the refrigerant.
  • Apart from the refrigerant, one more extra fluid in absorption chillers is the absorbent liquid. It is used in the absorber.
  • A single device of the compressor is used in an electric chiller; whereas four devices of absorber, heat exchanger, pump and generator are used in an absorption chiller. So, in terms of space consumption and area, an electric chiller occupies very less space as compared to an absorption chiller.
  • Energy consumption is less in an absorption chiller than in an electric chiller.
  • Pollution level is more in absorption chiller than in electric chiller, due to heating, combustion, fossil fuels, and natural elements present.
  • The maintenance and initial setup cost of an absorption chiller are higher than an electric chiller.
  • The performance of an electric chiller is higher than that of an absorption chiller.
  • Noise and vibration levels are higher in an electric chiller than in an absorption chiller.
  • There is a problem with crystallization in absorber liquid (lithium bromide mostly), if it becomes too cool. The electric chiller is free from such issues.
  • Heat dissipation requirements are larger in absorption chillers than in electric chillers.
  • An absorption chiller is best to use in conditions when you have plenty of waste heat or other abundant heat sources. This saves electricity to a great extent.

In this way, we understand the difference between an absorption chiller and an electric chiller.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Deep Hole Drilling Ideal Methods For CNC Machining
Piping and Instrumentation Drawing (P&ID) Tutorials – Part 4
Slip Rings in Robotics – Types, Applications, Advantages
Ultrapure Water in the Semiconductor Industry
Which HVAC System is Best for Home?
Condensate Automation in the Sugar Industry
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Streams After Electrical Engineering Graduation
What is Arduino? Different Models of Arduino Controllers
The Role of CNC Machining in Electronics Manufacturing
What is the Address Resolution Protocol? – Types of ARP
The Information About Resistor Color Code You Should Know
What is a Fotonic Sensor? – Working Principle, Advantages, Disadvantages
Custom Metal Fabrication Techniques for Quality Machined Parts
5 Valve Manifold Operation
NPT Connection Measurement Size
Aluminum CNC Machining: A Complete Guide You Cannot Miss

Keep Learning

Discrete Manufacturing Automation

Discrete Manufacturing Automation

Multiplexing

Introduction to Digital Systems

How to Train Your Maintenance Team for Industrial Automation Systems

How to Train Your Maintenance Team for Industrial Automation Systems?

Linear Programming in Excel

How to Do Linear Programming in Excel?

How do Electric Motors Work

All About Electric Motors and Universal Motors

control of pneumatic systems

Control of Pneumatic Cylinder and Motor

Best Online Courses to Learn Electrical Engineering

Best Online Courses to Learn Electrical Engineering

Food Safety Equipment And Tools

Food Safety Equipment, Tools, and Tips: A Guide For Businesses

Discover More

PLC Fault Diagnosis - PLC Training Documents

PLC Fault Diagnosis – PLC Training Documents

Improved Sprocket Segment Bolting to body

A Plant Bucket Elevators chains too short chain lives problem eliminated

Spectrometers Questions and Answers

X-Ray Spectroscopy Questions & Answers

Instrument Numbering Philosophy

Instrument Numbering Philosophy

Pneumatic Valves Questions & Answers

Pneumatic Valves Questions & Answers

Safety Questions and Answers

Safety Questions and Answers

Relay Permissive and interlock circuits

Basics of Permissive and Interlock Circuits

open vs closed loop

Open Loop and Closed Loop Animation