Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Deep-Bed Filters
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Process > Deep-Bed Filters

Deep-Bed Filters

Last updated: May 19, 2018 8:37 pm
Editorial Staff
Process
No Comments
Share
3 Min Read
SHARE

Filtration is a process used to remove suspended solids from a solution. Other processes such as demineralization remove ions or dissolved ions. Different filters and strainers are used for different applications. In general, the filter passage must be small enough to catch the suspended solids but large enough that the system can operate at normal system pressures and flows.

Deep-Bed Filters

Deep-bed filters are usually found only in makeup water systems, where they are used to filter water after it has been treated in a clarifier. They are used to remove organic matter, chlorine, and very fine particulate matter.

A deep-bed filter is based on a support screen (decking), which is mounted a few inches above the bottom of the tank. The screen is perforated to allow water to flow through it. A coarse, aggregate layer of crushed rock or large lumps of charcoal is placed on top of the screen, and the deep bed itself (2 to 4 feet of granular anthracite or charcoal) is placed on top of the aggregate. The filter is sized so that there is 1 to 2 feet of “free board” above the deep bed.

Deep-Bed Filter

When the filter is in service, raw water is pumped in through a pipe that feeds a distribution pipe above the deep bed. The water is filtered as it percolates down through the granules. (Charcoal granules will filter out organic matter, chlorine, and fine particulates, while anthracite granules remove only the particulates.) The water collects in the bottom of the tank, below the support screen, and leaves the filter through a pipe in the bottom of the filter vessel.

Deep-bed filters, like precoat filters, are cleaned by backwashing. Water is pumped through the distribution piping near the top of the filter. The flow rate of the water is kept high enough to lift the granulated charcoal or anthracite up into the free space. The water washes away the deposits that have accumulated. When the backwash cycle is completed, the flow is stopped, and the granules settle back down into the filter bed. The filter can then be put back into service.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Pumps Quiz
Compressor Anti-Surge Control near-miss incident
Types of Heat Exchangers
Filters in Compressors
Process Control Loop Testing
Bucket Steam Trap
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Difference Between ETP, STP, and WTP – Treatment Plants for Water
Heat Exchanger Root Cause Analysis (RCA)
Cartridge Filters
Rotary Compressors
Plant Air Storage Tank Pressure Fluctuations Root Cause Analysis
Introduction to Chemical Dosing System
Hazards of Compressed Air
Malfunctioning Inlet Check Valves caused chaos at Compressor stop/trip

Keep Learning

Difference Between Single-stage and Multi-stage Compressor

Difference Between Single-stage and Multi-stage Compressor

Components of a Water Treatment Plant

Components of Water Treatment Plant

Rotary Lobe Air Compressor

Centrifugal Compressors

Steam Turbine Driven Centrifugal Compressors Leak due to Broken Instrument

Discharge Head 3‑monthly leaks of Steam Turbine Driven Centrifugal Compressors

interview-questions-and-answers-on-natural-gas

Oil and Gas Interview Questions Answers

Compressor Coolers

Why counter-current heat exchangers are better than co-currents?

Why Counter-current Heat Exchangers are better than Co-current?

Water Treatment Industry

Water Softening Systems in Water Treatment Industry

Learn More

A Question on Steam Drum Water Level Measurement

A Question on Steam Drum Water Level Measurement

3-port-2-position-direct-acting-solenoid-valve

3 Port 2 Position Direct Acting Solenoid Valve Working Principle

Converter Instruction in Siemens PLC Programming

Converter Instruction in Siemens PLC Programming

liquid flow control system

Practical Process Control System Questions & Answers – 7

Heat Exchanger Baffles Holes

Heat Exchanger Tubes Corroded Root Cause Analysis

IP transducer

Pilot Valves and Pneumatic Amplifying Relays

Power Systems Questions & Answers

Power Systems MCQ Series 18

Pressure Transmitter Calibration Setup

Pressure Transmitter Preventive Maintenance

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?