Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Pitot Tube Flowmeter Calculations
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Practical Questions > Pitot Tube Flowmeter Calculations

Pitot Tube Flowmeter Calculations

Last updated: June 6, 2018 9:51 am
Editorial Staff
Practical Questions
No Comments
Share
1 Min Read
SHARE

A Pitot tube measuring the flow of glycerin (78.6 lb/ft3 ) produces a differential pressure of 35 inches W.C. at a mass flow rate of 450 pounds per minute.

Calculate the differential pressure produced by this same Pitot tube at a flow rate of 310 lb/min.

Calculate the mass flow rate at a differential pressure of 12.6 ”WC.

If the glycerin density happens to change from 78.6 lb/ft3 to 75.1 lb/ft3 , calculate the mass flow rate at a differential pressure of 24.8 ”WC.

Answer :

Differential pressure produced by this same Pitot tube at a flow rate of 310 lb/min = 16.61 ”WC

Mass flow rate at a differential pressure of 12.6 ”WC = 270 lb/min

Mass flow rate at DP of 24.8 ”WC, assuming density of 75.1 lb/ft3 = 370.3 lb/min

More DP Transmitter Questions

Flow Transmitter Readings mismatch with DCS
DP Transmitter Calibration Errors
DP Transmitter Error Calculations
Smart DP Transmitter Flow Meter Calculations

 

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

PLC Practice Questions
Galileo Thermometer
Programmable Logic Controller (PLC) Questions and Answers – 14
Simulate Different Values for Pressure Instrument Under Test
Thermocouple Terminal block Questions
Solenoid Valves Practical Problems
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Calculate Incident Power in Radar Level Measurement
Problem with Pirani Gauge
Determine Calibration Range of Pneumatic Pressure Transmitter
Draw a ladder logic circuit for the electric motor of an air compressor ?
Float-type Level Switch to Control a pump
Practical Process Control System Questions & Answers – 11
Problem with Sump Tank Level Transmitter
10 Questions on Reforming Furnace Control System

Keep Learning

buoyancy level transmitter

Displacer Level Transmitter Question & Answer

Determine the Pressure at Each Port of DP Transmitter

Determine the Pressure at Each Port of DP Transmitter

Process vessel for measuring water level

Level Measurement Lab Exercise

Two pressure switches

Identify Two Pressure Switches Logic

Transmitter Questions

Practical Process Control System Questions & Answers – 4

Steam flow to the heat exchanger

Analytical Process Control Question

Guided wave radar Measurement Principle

Instrument Salesperson Question

Hydrostatic level transmitter Formula

Hydrostatic Level Transmitter Questions

Learn More

Annunciator Panel

What is a Annunciator Panel?

Difference between PLC and HMI

Difference between PLC and HMI

Closed Tank Non-Zero-Based Direct Mount Application

Open and Closed Tank Level Calculations

Surface Detector Level Measurement System

Surface Detector Level Gauges (Plumb-bob)

Software Testing Projects

Software Testing Projects – How to Approach the Process Effectively?

valve trim

Valve Actuator Bench Set

DCS Vs PLC

Difference between DCS & PLC Systems

Ultrapure Water in the Semiconductor Industry

Ultrapure Water in the Semiconductor Industry

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?