Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Output Regulator & the Tracking Problem
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Output Regulator & the Tracking Problem

Output Regulator & the Tracking Problem

Last updated: November 27, 2021 5:40 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
4 Min Read
SHARE

Output Regulator & the Tracking Problem

1. For output regulator problem in performance index the parameter which is set to zero:

a) Input vector
b) Output vector
c) Control vector
d) State vector

Answer: b

Explanation: As the problem is to minimize the performance index involving output vector then the output vector must be close to zero.

2. In tracking problem the parameter reduced is :

a) Error
b) Output
c) Input
d) State

Answer: a

Explanation: In tracking problem the main objective is to reduce error and this is the main concern so as to reduce error.

3. Riccati equation is formed by using:

a) Output regulator problem
b) Finite state regulator problem
c) Infinite state regulator problem
d) Tracking problem

Answer: d

Explanation: Riccati equation can be formed using the results of the tracking problem as it is mainly applied in the cases where the errors are reduced to the minimum.

4. The value of K must further follow the following constraint that the closed loop system must be:

a) Asymptotically stable
b) Stable
c) Marginally stable
d) Conditionally stable

Answer: a

Explanation: The value of Ki must further follow the following constraint that the closed loop system must be asymptotically stable and this is due to the fact that the value of k matrix can be varied.

5. For suboptimal control the value of R is assumed to be:

a) Positive definite
b) Non-positive definite
c) Negative
d) Complex

Answer: b

Explanation: For suboptimal control the value of R is not assumed to be positive definite but it can also be assumed to be zero.

6. Which one of the following compensation is required for improving the transient response of the system?

a) Phase lead compensation
b) Phase lag compensation
c) Gain compensation
d) Both phase lag compensation and gain compensation

Answer: a

Explanation: For increasing or improving the transient response derivative controller is used and which is the phase lead compensation.

7. Pneumatic controller

a) Flexible operation
b) High torque high speed operation
c) Fire and explosion proof operation
d) No leakage

Answer: c

Explanation: Pneumatic controllers are fire and explosion proof operation as they require air and gas fuel for its operation.

8. Hydraulic controller:

a) Flexible operation
b) High torque high speed operation
c) Fire and explosion proof operation
d) No leakage

Answer: b

Explanation: Hydraulic controller must have no leakage and also it requires high torque and high speed operation due to high density of the controller.

9. Electronic Controller:

a) Flexible operation
b) High torque high speed operation
c) Fire and explosion proof operation
d) No leakage

Answer: a

Explanation: Flexible in all sense as it does not require heavy components or extra torque or high speed operations.

10. Which one of the following statement is correct?
A plant controlled by a proportional controller. If a time delay element is introduced in the loop its:

a) Phase margin remains the same
b) Phase margin increases
c) Phase margin decreases
d) Gain margin increases

Answer: c

Explanation: The introduction of a time delay element decreases both the phase and gain margin.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Pole Placement by State Feedback
Column Efficiency and Column Resolution Questions and Answers
Measurement and Instrumentation Objective Questions – Part 2
Block diagram Algebra Objective Questions
Operation of Chromatography Questions & Answers
Robotic Control System – Part II
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

pH Measurement Questions & Answers
The Infinite Time Regulator Problem
Bode Plots MCQ
PLC Interview Questions and Answers
Gamma Camera Questions & Answers
Concept of Stability in Control Systems
Stepper Motor MCQ
Detection System of Liquid Chromatography Questions & Answers

Keep Learning

pH Analyzers Questions and Answers

pH Meters Questions & Answers

Mass Spectrometer Questions and Answers

Tandem Mass Spectroscopy

Feedback Control Questions & Answers

Feedback Control Loop Questions & Answers

Ion Analyzers Questions and Answers

Special Designs of Ion Selective Electrodes Questions & Answers

Feedback Characteristics of Control Systems

Controller Components – Part 1 Objective Questions

Industrial safety Objective Questions and Answers

Top 10 Industrial safety Objective Questions

Top 100 Power Plant Engineering Objective Questions & Answers

Top 100 Power Plant Engineering Objective Questions & Answers

Optimal Control Systems

Optimal Control Problems – Part 1

Learn More

Off load Tap Changer Principle

Transformer Tap Changing Working Principle

importance-of-device-diagnostics

Importance of Device Diagnostics

Basic Components of HVAC System

Basic Components of HVAC System

Addressable Fire Alarm System

Which One is Best – Conventional or Addressable Fire Alarm System?

Explain how this is an example of Ratio Control?

Questions on Ratio Control System

Saybolt Viscometer

Saybolt Viscometer

Design Basis for Fire Detection and Alarm System

Design Basis for Fire Detection and Alarm System

Electrical Terminal Blocks

How to Protect Electrical Terminal Blocks From Tampering?

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?