Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Programmable Logic Controller (PLC) Questions and Answers – 6
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC
  • Control Systems
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Practical Questions > Programmable Logic Controller (PLC) Questions and Answers – 6

Programmable Logic Controller (PLC) Questions and Answers – 6

Last updated: June 6, 2018 10:06 am
Editorial Staff
Practical Questions
No Comments
Share
1 Min Read
SHARE

Suppose we have a PLC connected to three process switches as shown in this illustration:

PLC Programming Answers

In the above Diagram :

  • X1 to X4 : Digital Inputs
  • Y1 to Y4 : Digital Outputs

Determine the switch actuation statuses (i.e. low versus high process stimulus) given the “live” display of the ladder logic program shown here:

Level Switch PLC Ladder Logic

Also, determine the status of the lamp connected to the PLC’s Y1 output.

Answer :

  • Low level and high flow and high temperature.
  • The lamp will be de-energized.

Share Your Answer / Comments

Credits :  Tony R. Kuphaldt – under CC BY 1.0

For More PLC Questions : CLICK HERE

 

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Determine Calibration Range of Pneumatic Pressure Transmitter
Determine the Temperature of 3 Wire RTD
Practical Process Control System Questions & Answers – 6
Pressure Switch Questions
Air Compressor Control Circuit Problem
Calculate the Height of Glycerine
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Diagnosing Electric Motor Circuit
Heat Exchanger Differential Pressure Transmitter
Liquid Level Switch Control Logic
Pressure Gauge with Block and Bleed Valves
Questions on Resistive Tape Level Sensor
Pneumatic Force Balance Instrument
How much Pressure is applied to Inclined Water Manometer?
Double Block and Bleed Valves Opening or Closing Sequence

Keep Learning

Electronic Force Balance Pressure Transmitter

Electronic Force Balance Pressure Transmitter

Remote Seal Pressure Transmitter Temperature

Importance of Temperature in Remote Seal Pressure Transmitter

valve control system

Solenoid Valves Practical Problems

Type E thermocouple

Type E thermocouple Calculations

Identify Problem with Oily Water Filter Instrumentation

Identify Problem with Oily Water Filter Instrumentation

steadily pour a liquid into vertical tube

Vertical Tube Liquid Level Equilibrium

hydrostatic interface measurement calculation

Hydrostatic Pressure Measurement Questions

pressure transmitter calibration setup

Questions on Pressure Transmitter Calibration Setup

Learn More

HART Communication Interview Questions

HART Communication Interview Questions and Answers

SWAS Analyzer Questions

SWAS Analyzers Questions and Answers

PLC Commissioning and Testing

PLC Commissioning and Testing Procedure (Programmable Logic Controller)

How to Select the Right Encoder for Your Machine

How to Select the Right Encoder for Your Machine?

Intrinsic Safety Barriers

Intrinsically Safe Barriers Questions and Answers

Vortex Flow Meters

All About Vortex Flow Meters

Fire and Gas System

Types of Fire and Gas Detectors

Abbreviations of Pressure, Temperature & Flow

Abbreviations of Pressure, Temperature & Flow

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?