Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Ultrasonic Level Switch Working Principle
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Animation > Ultrasonic Level Switch Working Principle

Ultrasonic Level Switch Working Principle

Last updated: March 13, 2017 6:58 am
Editorial Staff
Animation How It Works Level Measurement Switches
3 Comments
Share
5 Min Read
SHARE

Ultrasonic Gap Switch Theory

An ultrasonic switch is a device that uses inaudible high-frequency sound (ultrasound) to detect the presence or absence of a liquid at a designated point. The device consists of an electronic control unit and a sensor. Ultrasonic level switches use the properties of sound transmission in vapor and liquids to detect liquid level. When sound travels in air, it loses a great deal of signal strength. When traveling in liquid, sound retains almost all of its signal strength.Ultrasonic Level Switch Working Animation

To detect liquid level, we must determine if there is a liquid or gas (air) in the gap. Since liquids have a higher density than gasses, it is easier to transmit sound through them. One side of the sensor gap transmits sound, the other side detects it. When liquid is present, a high amount of sound is received at the detection side. When gas (air) is present, a small amount of sound is received. The electronics detect this difference and switch a relay accordingly.

Ultrasonic switch sensors contain two piezoelectric crystals, one transmits sound and one receives sound. Each crystal is mounted on one side of a gap in the metal sensor. The transmit crystal generates high frequency sound (1MHz to 3 MHz) that is directed across the gap to the receiver crystal. The receiver crystal converts the sound energy received into an electric signal, which is processed by the electronics to determine if the gap has liquid or air in it.

Ultrasonic Gap Switch/Level Switch Working Principle

Ultrasonic Switches employ a pair of piezoelectric crystals that are encapsulated within epoxy at the tip of the transducer. The crystals are comprisedUltrasonic Gap Switch Working Principle of a ceramic material that vibrates at a given frequency when subjected to an applied voltage. When the voltage is sent from the electronics, one of the two crystals, the “transmitting crystal” converts the voltage to an ultrasonic signal.

The presence of liquid within the transducer gap allows the second crystal, the “receiving crystal” to sense the ultrasonic signal and converts it back into an electronic signal. The signal informs the electronics that liquid is present within the transducer gap. If no liquid is present, the ultrasonic signal is attenuated and cannot be detected by the receiving crystal.

The ultrasonic transducer continuously monitors the gap to determine the presence of liquid. When used as a high-level switch, the electronics will immediately actuate a relay if it detects a wet gap.Similarly when used as a low-level switch, it continuously monitors the gap for a dry condition.

Applications:

Ultrasonic level switches can be used in a wide variety of applications without any calibration or setup. However, there are limitations to the types of process they will work in.

The factors below must be taken into consideration before selecting an ultrasonic level switch for your application.

 Liquids only – the process media must be a liquid. The ultrasonic level switch cannot detect the difference between two gases or a gas and a solid. The even density of a liquid is required for proper detection.

 Clean liquids only – a liquid that has too high a percentage of solids will not transmit sound well enough to allow detection. Typically 5% suspended solids are the maximum amount allowed.

 The liquid must flow – an application where the liquid cannot drain out of the sensor gap will cause false alarms. If a liquid is too viscous to flow out of a 3/4” gap then the unit will not operate properly. Sometimes this can be solved by different mounting, but some liquids are just too viscous.

 No (or few) bubbles – especially in fluids with a higher viscosity. Large bubbles in thick fluids will block the sound signal from crossing the gap. Low viscosity fluids can have a fairly large amounts of bubbles as they tend to be very small (Alka-Seltzer in water). If these guidelines are properly observed, the ultrasonic level switches will provide trouble-free operation without any calibration or periodic adjustment.

Also Read: Anti surge Controller Working Principle

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Types of Industrial Level Sensors
RF Capacitance Level Switch Working Principle
Displacer Level Transmitter 5-point Calibration
Magnetostrictive Level Transmitter Working Principle
Radar Level Measurement
Guided Wave Radar Level Sensor Pressure and Temperature Effects
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
3 Comments
  • randy m. catalan says:
    December 18, 2015 at 11:31 pm

    thanks for additional information it helps a lot

    Reply
    • sagar bhagat says:
      February 20, 2016 at 7:37 am

      Awesome ? dear and thank you for your information

      Reply
  • Arpit Doshi says:
    February 22, 2016 at 8:09 am

    NIce one..!!

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

DP Transmitter Dry Leg & Wet Leg Calculations
Gas chromatograph Working Animation
Basics of Control Valves
Open and Closed Tank Level Calculations
DP Transmitters Level Measurement Principle Video
Proximity Switch Working Animation
Strain Gauge Animation
Boiler Drum Level Transmitter Calibration

Keep Learning

Bimetallic strip thermostat

Mechanical Temperature Measuring Sensors

Coriolis Mass Flow Meter Working Animation

Coriolis Meter Explained with Animation

Modbus in Industrial Networks

How Modbus is used in Industrial Networks?

Densitometers Principle

Vibrating Tube Densitometers Working Principle

Radar and Ultrasonic Level Transmitter Problems Troubleshooting

Radar and Ultrasonic Level Transmitter Practical Problems Troubleshooting

Hand Switch Pressed Working Animation

Pushbutton switches and Types of Switches

Magnetically coupled float indicates liquid level

What are Mechanical Level Indicators? – Classification & Principle

Reed Switch Principle

Reed switch Working Principle

Learn More

Fieldbus Wiring

Fieldbus vs 4-20mA

Cable Bending Radius

What is Cable Bending Radius? – Definition & Calculation

Emergency Shutdown Button Installation (ESD)

Understanding Emergency Shutdown Button Installation (ESD)

refrigeration compressors

Why is CO2 the Most Promising Refrigerant in Cooling Industry?

PLC Control Panel

Inside the PLC Control Panel: How Much Do You Know?

Level Transmitter

What is a Bridle?

Hydraulic Actuator

Types of Valve Actuators

What is Barring Gear Logic? Why is it Required in the Steam Turbine?

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?