Flow Measurement

What is Gas Meter and Regulating Station?

In this article, we will discuss about the gas meter and regulating station for commercial usage. This station is used for the natural gas distribution systems.

This is the Meter Regulating Station in Indonesia and is owned by Indonesia National Gas Company (PGN) or Perusahaan Gas Negara.

What is Gas Meter and Regulating Station

Before we discuss this plant in more detail, we must understand about the gas distribution system.

Gas Distribution System P&ID

From the drawing, we know that the Meter Regulating Station (M/RS) is located after the tie-in line from the PGN line.

The gas is about 5 – 30 Barg from the tie-in line for the M/RS inlet. In this M/RS the gas is filtered, regulated, and measured until this outlet is 1 – 4 Barg.

So, what makes the gas is at pressure-reduced conditions? So, let’s check for the part of the P&ID at the M/RS section. And knowing the datasheet from these stations.

On the datasheet, we know the maximum flow rate, pressure, and G-Size from Turbine Meter (G-250).

The first process is gas in from the inlet (insulation joint). There are 2 lines at upstream and downstream. We can know the pressure inlet from PG-01.

The gas is in via BV1/2A (Ball Valve). And after that, the gas passes the filter GF1/2 (Gas Filter) to filter the gas from impurities. And measured with the differential pressure gauge (DP).

The gas is about 5 – 30 Barg. And after the DP gauge, the gas is regulated by SSOV (Slam-Shut Off Valve) to 4,5 Barg, Pilot Regulator Monitor (PRM) 4,1 Barg, and Pilot Regulator Active (PRA) 4 Barg and will go to the downstream section to be calculated with Electronic Volume Corrector (EVC) who’s connected with the pressure sensor, temperature sensor, a turbine meter with encoder to record the flowrate.

After that, the gas measured this temperature with thermowell too (TW1/2) and go to outlet insulation joint section and measured by PG 02 (The author forget to draw the outlet pressure gauge, so the draw on this P&ID is small than other instruments).

There are the PRV1/2 (Pressure Relief Valve) to relieve the pressure if there is overpressure at the upstream pressure.

It usually happened if the usage of the gas is suddenly decreased. The PRV is set on 4.3 Barg.

The picture above is showing about the parameters is measured by EVC. There are Vm (Volume at measurement conditions or nPsiG) and Vb (Volume at base conditions or 0Psig).

So the EVC is used to convert the gas flow rate from measured condition to base condition. In this case, gas compressibility law is available.

PV = nRT

If the gas temperature is low, so the pressure and the volume will be decreased than at higher temperature conditions.

This equipment is equipped with a pressure sensor, temperature sensor (PT-100), and IGTM turbine meter G-250. It can be added by NAMUR sensor and Encoder. And we can monitor the gas composition such as C1, C2, C3, C4,….until H2.

The equipment is featured by RS485 communication. So the gas value from EVC is can be collected and monitored with SCADA wireless (using GPRS) or not (using RS485).

Gas Composition
EVC Wiring Configuration
EVC Inputs Configuration
EVC Pressure Sensor Inputs
EVC Installation Configuration
Insulation Joint at Inlet and Outlet Stream

To get good performance for the measure and regulating process at this gas distribution system, the equipment at the M/RS should be on good maintenance.

Author: Ramadhani Ichlasul Amal

Bachelor of Applied Instrumentation Engineering Sepuluh Nopember Institute of Technology (ITS). And now at Jargas Jombang Operational and Maintenance Team.

You've successfully subscribed !

View Comments

Share

Recent Articles

  • PLC Tutorials

Conveyor Sorting Machine PLC Program with Calculation Function

The conveyor sorting machine is widely used in the packing industries using the PLC program…

4 days ago
  • PLC Tutorials

Example of Flip-Flop PLC Program for Lamps Application

Learn the example of flip-flop PLC program for lamps application using the ladder logic to…

5 days ago
  • PLC Tutorials

STAR DELTA Programming using PLC Controller

In this article, you will learn the STAR DELTA programming using PLC controller to start…

5 days ago
  • Instrumentation Design

Single and Three Phase Immersion Electrical Heaters Wiring Circuits

Lube oil consoles of rotary equipment packages in industrial process plants are usually equipped with…

2 days ago
  • Instrumentation Design

Immersion Heaters in Lube Oil Consoles

Rotating equipment packages such as pumps, compressors, turbines need the lube oil consoles for their…

4 days ago
  • PLC Tutorials

How to Blink Lights in Ladder Logic?

This article explains how to blink lights in ladder logic with a detailed explanation video…

4 weeks ago