Practical Questions

What Effect on Hydrostatic Level Transmitter if Liquid Density Changes?

The lever transmitter (LT) in this level control system is hydrostatic; i.e. it senses liquid level in the vessel based on the hydrostatic pressure exerted by the liquid’s height in the vessel:

Hydrostatic Level Transmitter

What Effect on Hydrostatic Level Transmitter if Liquid Density Changes?

Suppose the density of the liquid within the vessel decreases. What effect will this have on the controlled liquid level?

In other words, what will the liquid level inside the vessel do over time in response to this change in density?

Be sure to explain why the level will be affected (or not affected), not just what will happen to the level.

Share your answers & explanation with us through the below comments section.

Read Next:

Credits: Tony R. Kuphaldt

You've successfully subscribed !

View Comments

  • If the density of the fluid changes, so the Level Transmitter will identify the level different that the real measurement of the Vessel. Density has a direct impact on volume by the formula is d = m/V.

  • The transmitter is deriving level form a pressure measurement.

    In this case Pressure = ρgh (density x gravity constant x height)

    A change in density will increase or decrease the pressure measured.
    In effect there is more or less weight on the diaphragm of the transmitter depending on how dense the liquid in the tank is.

  • Hola,

    Si la densidad disminuye, el transmisor LT lo interpretará como una disminución del nivel debido a que la presión medida se ve afectada por la densidad según la siguiente ecuación: P=h*g*d = m*m/s^2*kg/m3 = N/m2; debido a está variación en la medida el lazo de control LIC tratara de reducir la salida de la válvula para mantener el SP anterior a la reducción de la presión.

  • Hi,

    If the density decreases, the LT transmitter will interpret it as a decrease in the level because the measured pressure is affected by the density according to the following equation: P = h * g * d = m * m / s ^ 2 * kg / m3 = N / m2; Due to this variation in the measure, the LIC control loop will try to reduce the valve output to maintain the SP prior to the pressure reduction.

    Regards

Share

Recent Articles

  • PLC Tutorials

Conveyor Sorting Machine PLC Program with Calculation Function

The conveyor sorting machine is widely used in the packing industries using the PLC program…

4 days ago
  • PLC Tutorials

Example of Flip-Flop PLC Program for Lamps Application

Learn the example of flip-flop PLC program for lamps application using the ladder logic to…

4 days ago
  • PLC Tutorials

STAR DELTA Programming using PLC Controller

In this article, you will learn the STAR DELTA programming using PLC controller to start…

5 days ago
  • Instrumentation Design

Single and Three Phase Immersion Electrical Heaters Wiring Circuits

Lube oil consoles of rotary equipment packages in industrial process plants are usually equipped with…

2 days ago
  • Instrumentation Design

Immersion Heaters in Lube Oil Consoles

Rotating equipment packages such as pumps, compressors, turbines need the lube oil consoles for their…

4 days ago
  • PLC Tutorials

How to Blink Lights in Ladder Logic?

This article explains how to blink lights in ladder logic with a detailed explanation video…

4 weeks ago