Root Cause Analysis (RCA): Steam Turbine Driven centrifugal compressors K-601’s IP case discharge temperatures gradually increases & lead to plant shutdown.
Article Type: | Root Cause Analysis (RCA) |
Category: | Mechanical |
Equipment Type: | High Speed, Hi KW Major Rotating Machines |
Author: | S. Raghava Chari |
Note: This root cause analysis (RCA) is from real-time scenarios that happened in industries during the tenure of one or two decades ago. These articles will help you to improve your troubleshooting skills and knowledge.
Steam Turbine Driven Synthesis gas (SG) centrifugal compressors K-601’s IP case discharge temperatures gradually increased to unacceptable 220o C from initial 160o C and throughput gradually decreased to 90% in 6‑months.
Consequent 2-days six-monthly plant shutdowns were perennial problems
The author noted the crew changed the IP case suction all impellors’ labys instead of just the found eroded discharge end last 2-labys only, due to some past developed the wrong notion. The author instructed changing eroded labys only and saved 80% spares costs.
The LP case outlet moisture separator (MS) Level Controller (LC) regularly dumping confirmed it removes moisture from the syngas as expected.
His relentless rigorous thinking revealed that too small water droplets and some water vapor could escape from the LPC MS and enter the IPC along with the SG.
The water vapor could condense into liquid water at the last two labys where the gas pressure is high and hence the water vapors’ partial pressure too. The condensed water could erode the last two labys.
He recollected a journal advertised Super Moisture Separator (SMS). The ad said that the SMS traps, coagulates, and discharges even trace moisture, water vapor, mist, and micron-sized water particles from gases.
The plant accepting his suggestion ordered the SMS. The crew readied the foundation to place the SMS and the necessary piping to connect the SMS to the compressor piping.
On its arrival after six months of order completed the connections during an opportune short SD and took the SMS in service.
Realized Benefits are:
Author: S. Raghava Chari
Do you face any similar issues? Share with us through the below comments section.
If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.
You can also follow us on Facebook and Twitter to receive daily updates.
Read Next:
Rotating equipment packages such as pumps, compressors, turbines need the lube oil consoles for their…
This article explains how to blink lights in ladder logic with a detailed explanation video…
In this article, a simple example will teach you the conversion from Boolean algebra to…
In this article, you will learn the PLC cooking timer example for kitchen automation using…
Learn an example PLC program to control a pump based on level sensors using ladder…
In the PLC timer application for security camera recording, when motion is detected then camera…