Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Proximity Switch Working Animation
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Animation > Proximity Switch Working Animation

Proximity Switch Working Animation

Last updated: August 7, 2018 10:11 am
Editorial Staff
Animation How It Works Switches
4 Comments
Share
1 Min Read
SHARE
Proximity Switch Working Animation
Proximity Switch Working Animation

A proximity sensor is a sensor able to detect the presence of nearby objects without any physical contact.

Proximity switches open or close an electrical circuit when they make contact with or come within a certain distance of an object. They are most commonly used in on-off valves feedbacks, manufacturing equipment, robotics, and security systems. There are four basic types: infrared, acoustic, capacitive, and inductive.

Inductive proximity switches sense distance to objects by generating magnetic fields. They are similar in principle to metal detectors. A coil of wire is charged with electrical current to produce electromagnetic field , and an electronic circuit measures this current. If a metallic part gets close enough to the coil, the current will change and the switch will open or close accordingly. The chief disadvantage of this type is that they can only detect metallic objects.

Proximity Switch Circuit Diagram Operation
Proximity Switch Circuit Diagram Operation

Also See : Instrumentation online Calculations Tools

 

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Probe Type GWR Level Transmitter Working Animation
Capacitive Level Switch Principle
Hydrostatic Level Measurement
Ultrasonic Flow Meters Working Principle
Animation of Electromagnetic Relay
Control Valve Working Animation
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
4 Comments
  • Pankaj Lanjewar says:
    August 14, 2015 at 3:33 pm

    Instrumentation tools is a wonderful site for instrumentation engineer who is worked in field. continue update.

    Reply
  • Mahendra Mundada says:
    August 15, 2015 at 10:40 am

    Very Good Site, can you also post remote seal Level transmitter calibration with transmitter mounted at 75% of span or above the hp tapping

    Reply
  • Abhishek Singh Tomar says:
    May 28, 2016 at 3:12 am

    Really It’s a very knowledgeable Site for Instrument Engineer. And Also We can See the working of Instrument in Animation Mode….

    Reply
  • José Cárdenas says:
    December 13, 2017 at 12:11 am

    Really very good support for people dedicate to maintenance and automation of instrumentation!!

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Optical Level Switch Working Principle
Stepper Motor Working Principle
How a 4-20mA Transmitter Works?
Belt Sway Switch Working Principle
Cat and Mouse type Level Indicator
Side Mounting Float Switch Working Principle
Temperature Switch Working Principle
Proximity switches Circuit Diagram Operation

Keep Learning

Oval Gear Flow Meter Principle

Oval Gear Flow Meters – Principle, Advantages, Animation

Types of Limit Switches

Types of Limit Switches – Principle, Advantages, Disadvantages

Electromagnetic limit switch

Electromagnetic and Conductive limit switches Principle

Ultrasonic-Level-Transmitter-Animation

Ultrasonic Level Transmitter Animation

PID Controller Gains Effect on Setpoint

PID Controller Gains Effect on Manipulated Variable

ultrasonic-level-measurement

Ultrasonic Level Transmitter Working Principle

Basics of Butterfly Valves

Gas-chromatograph-Working-Principle

Gas chromatograph Working Animation

Learn More

Semi Conductor or Piezo Resistive Strain Gauge Principle

Semi Conductor or Piezo Resistive Strain Gauge Principle

PLC Memory Organization - Data Files and Program Files

PLC Memory Organization – Data Files and Program Files

Resistance Temperature Detector (RTD) Questions

Resistance Temperature Detector (RTD) Questions – 1

Calibrating Transmitter System One Seal with suppressed Zero

Calibrating Level Transmitter with Remote Seals

PLC-based mail box automation

PLC Program for Mailbox with Letter Counting & Light Indicators

Optical Fiber Cable - SC and ST Optical Fiber Connectors

Optical Fiber Cable – SC and ST Optical Fiber Connectors

SCADA

Top 100+ SCADA Questions

Rupture Disc

Rupture Discs bursts caused too many Urea Plant Shutdowns

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?