Reading: Use of Regions in SCL Language
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > PLC Tutorials > Use of Regions in SCL Language

Use of Regions in SCL Language

Find out how the use of regions in SCL language can improve your programming efficiency and make troubleshooting easier.

Last updated: March 15, 2025 4:06 pm
Viral Nagda
PLC Tutorials
No Comments
Share
4 Min Read
SHARE

TIA PORTAL provides one very interesting option where you can keep all your codes in separate areas. This helps for ease in troubleshooting. Due to this, if there is any issue in a code, you can see clearly which area has faults. Then, you can access that code and solve it. This option is called a region in SCL language. In this post, we will see how to use regions in the best way in SCL language.

Contents
What is a region in the SCL language?How to write regions in the SCL language?

What is a region in the SCL language?

A region is a feature by which you can structure your codes in specific defined areas. You have to name these regions and due to this, you will get a clear idea of what you have written in the program. Simply speaking, suppose there are 20 lines in a code. Out of that, the first 10 lines perform a different task and the other 10 lines perform a different task. Means, there are 2 groups in short. So, we can name these two groups as regions. Due to this, a programmer will know that there are two types of statements working in a code.

Regions can be expanded or collapsed in view. Due to this, the navigation becomes fast and you can decide which region to show and which region to hide. One more feature is that if a particular line in a region has an error, then that region will be highlighted with a cross mark. Due to this, you can quickly navigate to that region and rectify that fault.

How to write regions in the SCL language?

Refer to the below image. Here, we have defined two regions. One is named as for and the other is named as while_do. The general syntax for writing a region is:

Region name

Statements

End_Region

So here, the first region covers the for statement written. The second region covers the while-do statement written. You can name the region in any way you require. You can use the – tab for expanding or collapsing a view as shown.

Use of Regions in SCL Language

In the second image below, you can see a collapsed view of the regions. Due to this, you can clearly understand how many separate groups are working in a code. The variables may be linked in the whole program, but you can at least distinguish the groups which work in a similar manner.

On the left hand side, you can see the region names and even expand or collapse the view by clicking there. This also clearly helps in understanding the number of regions written in a section. When the arrow is down, it means the view has been expanded. When the arrow is right, it means the view has collapsed.

SCL Regions in TIA Portal

In the third image below, you can see a compile error written on line no.41, where the end keyword was commented. Due to this, that particular region showed a red cross mark as shown. This helps the programmer to quickly visit that region and see where the fault is.

Siemens SCL Region Programming Example

You can also right-click the region name and copy-paste it. This simplifies the process even more easily. Also, you can nest regions within regions. But remember to end them correctly; otherwise, a compile error will occur.

In the next post, we will see how to write a repeat-until statement in SCL language.

Read Next:

  • Flip-Flop PLC Programming Examples
  • PLC Manual Sequential Machine Program
  • Automatic Railway Crossing Gate Control
  • Siemens PLC Program Course for Beginners
  • Sequential Batch Mixing PLC System Program
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Compare Servo Motor and Stepper Motor
Software Troubleshooting Errors and Faults in Siemens PLC
How to Train Your Maintenance Team for Industrial Automation Systems?
Push button Motor PLC Logic
Various Causes for PLC Going in Stop Mode
Scale and Normalize Instructions in PLC
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Electrical Switches Principle & Types
What are Analog and Digital Signals? Differences, Examples
Types of PLC
How to Use Diagnostic Buffer for SIEMENS PLC?
Example PLC Program to Control a Pump based on Level Sensors
Functional Block Diagram in PLC for Oil and Water Process
Converter Instruction in Siemens PLC Programming
Various Control Methods in Servo Motor Drives

Keep Learning

Siemens PLC Force LED

Forcing and Modifying PLC Logic

Retro-Reflective Sensor

What is a Retro-Reflective Sensor? – Principle, Applications

Field Instruments Questions and Answers

Control Room and Field Instruments Questions and Answers

PLC Important Questions and Answers

PLC Important Questions and Answers

Types of Limit Switches

Types of Limit Switches – Principle, Advantages, Disadvantages

PLC Program for Washing Machine

PLC Program for Washing Machine

Wonderware Recipe Manager Plus

What is Recipe Management in SCADA?

PLC Ladder Logic for Motor Control

PLC Program for Motor Starter

Learn More

Omron PLC real-time clock street lighting program

Automatic Highway Lights Program using RTC in Omron PLC

Selecting Directional Valves

How to Select a Directional Valves

Bus Riser in Switchgear

Bus Riser in Switchgear

Sensors and Transducers Objective Questions

Transducers Objective Questions

Radiochemical Questions and Answers

Gamma Camera Questions & Answers

Servo Valve

Proportional Valve and Servo Valves

Proportional Band example

Why Offset in Proportional Controller ?

Allen-Bradley MicroLogix 1000 controller

PLC Switch Actuation Status

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?