Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Read Gas Composition from Gas Metering System using RS485 Protocol
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Control Systems > Read Gas Composition from Gas Metering System using RS485 Protocol

Read Gas Composition from Gas Metering System using RS485 Protocol

How to Get Gas Composition and Process Variables Data from Gas Metering and Regulating Station using RS485 serial communication Protocol?

Last updated: December 14, 2021 12:19 pm
Editorial Staff
Control Systems Flow Measurement
2 Comments
Share
6 Min Read
SHARE

Article: How to Get Gas Composition and Process Variables Data from Gas Metering and Regulating Station Using RS485 or RS232 serial communication Protocol?

Contents
Gas Metering SystemElectronic Volume Corrector Configuration at MRS PipelineMetering System using RS485 ProtocolRS 485 to USB ConverterRS 232 to USB ConverterFlowSolv SoftwareGasComm SoftwareSCADA System

Read my first article: What is Gas Meter and Regulating Station?

This time we will discuss about how to get gas composition values (like C1, C2, C3,…) and process variables data (like pressure, temperature, flow rate, volume at measurement condition, and volume at the base condition) from gas metering system.

First, we must know about custody transfer metering in the oil and gas industry. The concept is we need to measure the plant oil and gas production using a metering system before transferring to the outside world like power plants, companies, household applications, etc.

Gas Metering System

Here we use an Electronic Volume Corrector (EVC) at Gas Metering and Regulating Station (MRS). This instrument works to convert the gas at the measurement condition (Vm) to the base condition (Vb).

The EVC configuration includes sensors at the MRS pipeline connection is shown in the below picture.

Gas Metering System Using RS485 Serial Communication Protocol

Electronic Volume Corrector Configuration at MRS Pipeline

The conversion process at EVC is using American Gas Association 8 (AGA 8) Detail and NX (for Nitrogen and Carbon Monoxide only) calculation. The data for the conversion process by EVC with AGA 8 Detail is from the turbine meter that uses the AGA 7 Calculation.

And what do we need from the EVC? We need a :

  1. Gas Compotition Data
  2. Gas Variables Conditions (P,T,V)

And how we can get the data?

The answer is by checking the EVC manually (via HMI interface) or using an RS485 serial communication protocol.

By using the EVC HMI interface is like the picture below.

Gas Composition PTZ Box
Getting Gas Composition Information using EVC HMI

So we must turn on the EVC and go to the gas composition menu. The gas parameters will be displayed on the HMI as shown in the above image.

We can also read the gas composition using the RS485 protocol and display the data on a laptop or a computer.

Metering System using RS485 Protocol

Electronic Volume Corrector (EVC) Serial Communication
                      Getting Gas Composition Information using EVC RS232 Port

The below-mentioned tools are required to get the data from the controller and software reads this data using a PC.

The main devices are RS485/RS232 serial communication converters.

As we don’t have dedicated RS 232 or RS 485 serial ports in our laptop or PLC, we use RS485/232 to USB converters to connect to the laptop.

RS 485 to USB Converter

RS485 to USB Converter
RS485 to USB Converter

RS 232 to USB Converter

RS 232 to USB Converter
RS232 to USB Converter

Now we use these converters to connect the Electronic Volume Corrector to our laptop or PC.

FlowSolv Software

We use a laptop to read the gas composition data. We will connect the USB converter to the laptop. We will open software called “FlowSolv”.

Using the FlowSolv software, we can read the gas composition data and generate a report as shown in the below image.

FLOWSOLV oil and gas fluid and flow calculation software
Flowsolv Software

So by using the Flowsolv Software we will Know about Gas Composition at Meter Regulating Station (MRS).

GasComm Software

Then we use a software named GasComm to get the gas variable conditions details as shown in the below image.

GasComm Software
GasComm Software

From GasComm software, we can make a report about gas composition and other process variables data.

After the gas flow rate has been converted to standard condition, the EVC will send the measurement data using a modem or GPRS communication to the billing server from the oil and gas industry company.

SCADA System

The data can be monitored by the SCADA system by using additional hardware at the system.

Turbine Meter in Gas Metering System

The above figure shows the EVC data Transmission & Configuration to System Billing/SCADA with Turbine Meter.

The below figure shows the transfer of data to the billing system/SCADA.

Billing SCADA
EVC data Transmission to System Billing/SCADA

And to transfer the data to the billing system/SCADA, we use the additional equipment (INT-S3 and EM-1 Module) as shown in the below image.

Custody Metering System SCADA
EVC data Transmission to System Billing/SCADA Using Digital Output Configuration

For additional information, the EVC readout using RS485 is must need external power supply addition.

And for data transfer activity for SCADA or billing system is needed additional batteries inside the EVC box as shown in the below image.

Power Supply of Electronic Volume Corrector
EVC Additional Power Supply Input

Author: Ramadhani Ichlasul Amal

Ramadhani Ichlasul Amal

Bachelor of Applied Instrumentation Engineering Sepuluh Nopember Institute of Technology (ITS). And now at Jargas Jombang Operational and Maintenance Team.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Recommended Articles

What is an Orifice Flange? – Purpose and Applications
Flare Ultrasonic Flow Meter – SOPAS Engineering Tool
What is a Turbine Flow Meter?
Learn about SCADA and HMI Systems
Instrumentation Engineer Activities & Documents – Detail Design Phase
How to Download PlantPAx Library?
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
2 Comments
  • NGUYEN TUAN VU says:
    June 13, 2022 at 12:56 pm

    The difference in Vb(Sm3) on EVC when installing 02 Turbine meter + EVC EK220 of Honeywell (Gas measurement) is about 1km apart. Why is there such a difference? Thank so very much.

    Reply
  • George Donkor says:
    March 18, 2023 at 4:43 pm

    How can I get a link to download the GasComm software

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • William Snyder on Top Non-PLC Certification Courses for Automation Professionals
  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

L2F insertion-style flowmeter

Optical Flow Meter Principle

Network Switch

Network Switch Port Allocation Details

Pressure and Level Control Loop

Problem on Pressure and Level Control Loops

ESD System Insights

ESD System Insights: Signals for Emergency Valve Shutdown Explained

Control System Basic Wiring Practice Animation

PLC Connection between Instrument, Junction Box, Marshalling & System Cabinet

Electrical and Instrumentation Engineering Documents

Electrical and Instrumentation – Automation Pre-engineering Documents

Serial Communication Error Checking Methods and Algorithms

Serial Communication Error Checking Methods and Algorithms

How to Select a Rotameter? – Parameters and Applications

More Articles

Sensors and Transducers Test

Sensors and Transducers Test

H & B Gas Analyzer Principle and Calibration Procedure

Closed Tank DP Level Transmitter

How to Find LRV and URV of Closed Tank DP Level Transmitter

Transformer Tap changer

Ferroresonance in Power Transformers

Air Consumption Calculation for Control Valves

Air Consumption Calculation for ON/OFF Valves

Deluge System for Transformer Protection

Deluge System for Transformer Protection Animation

How to Calibrate pH Electrode?

How to Calibrate pH Electrode?

Hydrogen sulfide gas

Hydrogen Sulfide Gas (H2S)

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?