Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: What Effect on Hydrostatic Level Transmitter if Liquid Density Changes?
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Practical Questions > What Effect on Hydrostatic Level Transmitter if Liquid Density Changes?

What Effect on Hydrostatic Level Transmitter if Liquid Density Changes?

Suppose the density of the liquid within the vessel decreases. What effect will be on hydrostatic level transmitter (LT)?

Last updated: February 10, 2021 11:28 am
Editorial Staff
Practical Questions
4 Comments
Share
1 Min Read
SHARE

The lever transmitter (LT) in this level control system is hydrostatic; i.e. it senses liquid level in the vessel based on the hydrostatic pressure exerted by the liquid’s height in the vessel:

Hydrostatic Level Transmitter

What Effect on Hydrostatic Level Transmitter if Liquid Density Changes?

Suppose the density of the liquid within the vessel decreases. What effect will this have on the controlled liquid level?

In other words, what will the liquid level inside the vessel do over time in response to this change in density?

Be sure to explain why the level will be affected (or not affected), not just what will happen to the level.

Share your answers & explanation with us through the below comments section.

Read Next:

  • Liquid Level Sensors Symbols
  • Level Gauge Interface Problem
  • Tank Design and Accuracy
  • Sump Tank Level Transmitter
  • Guided Wave Radar Level Sensor

Credits: Tony R. Kuphaldt

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Paint Mixing System
Why Pressure Vessel Connected to Tubing System?
Heat Exchanger Differential Pressure Transmitter
Which Instrument is Faulty? Transmitter, Recorder, or Controller
Draw Limit Switch Symbol ?
Pneumatic Force Balance Instrument
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
4 Comments
  • Flávio Stefani says:
    February 10, 2021 at 4:54 pm

    If the density of the fluid changes, so the Level Transmitter will identify the level different that the real measurement of the Vessel. Density has a direct impact on volume by the formula is d = m/V.

    Reply
  • Gary Donaldson says:
    February 10, 2021 at 8:30 pm

    The transmitter is deriving level form a pressure measurement.

    In this case Pressure = ρgh (density x gravity constant x height)

    A change in density will increase or decrease the pressure measured.
    In effect there is more or less weight on the diaphragm of the transmitter depending on how dense the liquid in the tank is.

    Reply
  • Alberto Fernández says:
    February 11, 2021 at 3:36 am

    Hola,

    Si la densidad disminuye, el transmisor LT lo interpretará como una disminución del nivel debido a que la presión medida se ve afectada por la densidad según la siguiente ecuación: P=h*g*d = m*m/s^2*kg/m3 = N/m2; debido a está variación en la medida el lazo de control LIC tratara de reducir la salida de la válvula para mantener el SP anterior a la reducción de la presión.

    Reply
  • Alberto Fernández says:
    February 11, 2021 at 3:38 am

    Hi,

    If the density decreases, the LT transmitter will interpret it as a decrease in the level because the measured pressure is affected by the density according to the following equation: P = h * g * d = m * m / s ^ 2 * kg / m3 = N / m2; Due to this variation in the measure, the LIC control loop will try to reduce the valve output to maintain the SP prior to the pressure reduction.

    Regards

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Identify the Pressure Gauge Error
Instrument Lab Exercise – Ranging and Manometer Usage
How to Connect Proximity Switch (Sink Type) to Make LED ON ?
Surface-mounted Water Pump
Calculate Process Temperature using a Thermocouple
How much Pressure is applied to Inclined Water Manometer?
How much Pressure will Remote Seal Pressure Transmitter Indicate?
Solenoid-controlled Valve Problem

Keep Learning

PLC program to control a water pump

PLC Program to Control a Water Pump

AB PLC Temperature Switch

Programmable Logic Controller (PLC) Questions and Answers – 17

pH Monitoring System Triggers an Alarm

pH Monitoring System Triggers an Alarm

displacer level transmitter configuration

Displacer Level Transmitter Questions

Problem with Pirani Gauge

Problem with Pirani Gauge

solenoid valves trip

Identify Solenoid Valves Energized or de-energized?

Questions on Resistive Tape Level Sensor

Questions on Resistive Tape Level Sensor

burner management system P&ID

Solenoid Valves Questions & Answers – 1

Learn More

Installation and Maintenance of Control Valves

Installation and Maintenance of Control Valves

Wiring Diagram Forward-Reverse for 3 Phase Motor

Motor Forward and Reverse Direction Control using Limit Switches

Electronic Devices & Circuits Objective Questions

Electronic Devices & Circuits Quiz – Set 15

Jet Pump

What is a Jet Pump? – Principle, Types, Comparison

Optimal Control Systems

Output Regulator & the Tracking Problem

Current Law

Applying Kirchhoff’s Current Law

Alarm prioritization

What is Alarm Prioritization? – Types of Alarms

Fiber Optic Measurement Techniques

Fiber Optic Measurement Multiple Choice Questions (MCQ)

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?