Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: What Effect on Hydrostatic Level Transmitter if Liquid Density Changes?
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Practical Questions > What Effect on Hydrostatic Level Transmitter if Liquid Density Changes?

What Effect on Hydrostatic Level Transmitter if Liquid Density Changes?

Suppose the density of the liquid within the vessel decreases. What effect will be on hydrostatic level transmitter (LT)?

Last updated: February 10, 2021 11:28 am
Editorial Staff
Practical Questions
4 Comments
Share
1 Min Read
SHARE

The lever transmitter (LT) in this level control system is hydrostatic; i.e. it senses liquid level in the vessel based on the hydrostatic pressure exerted by the liquid’s height in the vessel:

Hydrostatic Level Transmitter

What Effect on Hydrostatic Level Transmitter if Liquid Density Changes?

Suppose the density of the liquid within the vessel decreases. What effect will this have on the controlled liquid level?

In other words, what will the liquid level inside the vessel do over time in response to this change in density?

Be sure to explain why the level will be affected (or not affected), not just what will happen to the level.

Share your answers & explanation with us through the below comments section.

Read Next:

  • Liquid Level Sensors Symbols
  • Level Gauge Interface Problem
  • Tank Design and Accuracy
  • Sump Tank Level Transmitter
  • Guided Wave Radar Level Sensor

Credits: Tony R. Kuphaldt

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Recommended Articles

Identify the Purpose of Flow Ratio Controller
Define Normal Status of a Process Switch ?
Calculate Amount of Weight Indicated by the Scale
How to Decrease Span of Pressure Gauge?
Example PLC Program
Solenoid Valves Questions & Answers – 3
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
4 Comments
  • Flávio Stefani says:
    February 10, 2021 at 4:54 pm

    If the density of the fluid changes, so the Level Transmitter will identify the level different that the real measurement of the Vessel. Density has a direct impact on volume by the formula is d = m/V.

    Reply
  • Gary Donaldson says:
    February 10, 2021 at 8:30 pm

    The transmitter is deriving level form a pressure measurement.

    In this case Pressure = ρgh (density x gravity constant x height)

    A change in density will increase or decrease the pressure measured.
    In effect there is more or less weight on the diaphragm of the transmitter depending on how dense the liquid in the tank is.

    Reply
  • Alberto Fernández says:
    February 11, 2021 at 3:36 am

    Hola,

    Si la densidad disminuye, el transmisor LT lo interpretará como una disminución del nivel debido a que la presión medida se ve afectada por la densidad según la siguiente ecuación: P=h*g*d = m*m/s^2*kg/m3 = N/m2; debido a está variación en la medida el lazo de control LIC tratara de reducir la salida de la válvula para mantener el SP anterior a la reducción de la presión.

    Reply
  • Alberto Fernández says:
    February 11, 2021 at 3:38 am

    Hi,

    If the density decreases, the LT transmitter will interpret it as a decrease in the level because the measured pressure is affected by the density according to the following equation: P = h * g * d = m * m / s ^ 2 * kg / m3 = N / m2; Due to this variation in the measure, the LIC control loop will try to reduce the valve output to maintain the SP prior to the pressure reduction.

    Regards

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • William Snyder on Top Non-PLC Certification Courses for Automation Professionals
  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Chemical Seal Pressure Transmitter

What is the Purpose of Chemical Seals Pressure Transmitter?

Determine the Pressure at Each Port of DP Transmitter

Determine the Pressure at Each Port of DP Transmitter

Sump Tank Level Transmitter

Problem with Sump Tank Level Transmitter

Digital Pressure Gauge Animation

Air Pressure Inside the Tank

Steam Eductor Question

A Series of False Pressure Alarms

liquid flow control loop

Liquid Flow Control Loop Controller Action

Calculate Total Hydrostatic Pressure at Bottom of Vessel

Calculate Total Hydrostatic Pressure at Bottom of Vessel

measure the temperature of RTD

Measure the Temperature of the RTD

More Articles

Solar Arrays

Solar Photovoltaic Cells – Parts of the Solar Panel

Interview Questions on Transformers

Electrical & Instrumentation QC Interview Questions

Weir Flow Meter Principle

Measure Flow rate using Level Sensors

Calculate Power in Parallel RL Circuit

Calculate Power in Parallel RL Circuit

PLC Program for Fishpond Water Level Monitoring System

PLC Program for Artificial Fishpond Water Level Monitoring System

What is electrical transformer

Basics of Electrical Transformer

Infrared Open Path Gas Detectors Operation

Infrared Open Path Gas Detectors Working Principle

Three Phase Induction Motor Interview Questions & Answers

Three Phase Induction Motor Interview Questions & Answers

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?