Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: What is Capillary Tubing? – Advantages and Disadvantages
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Pressure Measurement > What is Capillary Tubing? – Advantages and Disadvantages

What is Capillary Tubing? – Advantages and Disadvantages

Capillary tubing is used to separate the direct connection between the measuring instrument and the process tapping point.

Last updated: October 17, 2023 2:10 pm
R Jagan Mohan Rao
Pressure Measurement
No Comments
Share
6 Min Read
SHARE

A capillary is generally built up from a tube, an armor, and optionally a protective sleeve.

Contents
Capillary Tubing PrincipleImportance of Capillary TubingTube SizeCapillary Tube MaterialPrecautionsProcess Temperature EffectAmbient Temperature EffectMounting EffectAdvantagesDisadvantages of Capillary TubingApplications of Capillary Tubing

Capillary Tubing Principle

The capillary tube is of small internal diameter, an appropriate method for separating a pressure instrument such as a gauge or transmitter from the process tapping/connection.

Capillary tubing is used to separate the direct connection between the measuring instrument and the process tapping point.

We can install the instrument as per our convenience and easy access for the maintenance. The capillary tubing is filled with some liquid inside it, usually it is glycerine but can be changed as per application need.

With help of this, the readings can be taken at a more convenient and accessible location to meet the demand for remote measurement/reading. 

Capillary tubes also serves as the purpose of a cooling element as the distance between the process tapping and the instrument will be more than the direct type installation. Also, there will be no direct contact between the instrument sensor and the process.

What is Capillary Tubing
Image Courtesy: Micro

Importance of Capillary Tubing

A capillary tube is commonly used to connect the diaphragm seal remote with the pressure instrument.

It allows separation between the measuring instrument such as pressure gauge or transmitter with the process connection.

Using a capillary tube on a mechanical gauge normally requires the use of a gauge supporting arrangement and gauge adaptor or some other form of surface mount.

In a temperature measurement, the pneumatic temperature transmitter is connected with a sensor.

The sensor is a bulb filled with either mercury, gas, or vapor.

Through the capillary tube, expanded bulb fill makes the movement of the bellows or a C- type bourdon tube as per the corresponding temperature of the process medium.

The transmitter is located at an accessible place.

Tube Size

1/16 inch to 1/8 inch capillary tubes are used in instrumentation applications.

Capillaries with suitable diameters are used for optimal performance.

Capillary Tube Material

  • Stainless steel,
  • Copper,
  • Inconel,
  • Hastelloy.

Precautions

Precautions when using a capillary tube:

  • Process temperature effect.
  • Ambient temperature effect.
  • Mounting effect.

Process Temperature Effect

Process temperature effect on the diaphragm seal and of the fill fluid in the capillary through heat transfer.

The capillary tube has an excellent function for cooling down of process temperature changes.

But, the warming through of the process media temperature that causes the capillary tube to fill liquid to either expand or contract, the possibility of changing the volume of the fluid.

This is possible in the case of the short length of the capillary, this generates an error in the pressure reading as a function of the change of total volume of the tubing, pressure instrument, and diaphragm seal.

Ambient Temperature Effect

It includes seal temperature effect and ambient temperature effect.

Exposure of an electronic pressure transmitter to excessively high ambient or process temperature can impair the instrument operation, affect its performance or even lead to a partial or total failure of the instrument.

To prevent exposure to excessively high ambient temperatures.

Consider installing the instrument in a safe area from major heat sources.

In extremities, cool down the instrument vicinity using compressed air or any equivalent mean.

The seal temperature effect relates to the pressure produced on the diaphragm when the temperature changes. The pressure is corresponding to an expansion or contraction of the fill fluid in the capillary.

Mounting Effect

A level difference between the installed pressure instrument and the diaphragm seal creates a pressure indication error.

But, by the method of a known level difference can be compensated for during the calibration of the diaphragm seal assembly.

On differential pressure (DP) applications, the sealing effect is usually compensated by having the same length of capillaries for both LP and HP ports of the instrument.

Advantages

Protecting the instrument from high or low process temperature effects.

Personnel safety due to proper accessibility. 

Disadvantages of Capillary Tubing

Longer capillary lengths affect the accuracy as subjected to ambient temperature effects.

Capillary length to be as short as possible to avoid delay response time.

Applications of Capillary Tubing

  • Distant reading.
  • Capillary is to be used in combination with gauges, diaphragm seals, transmitters, switches.
  • Chromatography.

Read Next:

  • Process Control Loop Testing
  • Question on Remote Seal with Capillary Tubing Transmitter
  • DP Transmitter Interface Level Measurement Principle
  • Calibration for Diaphragm Seal with Capillary
  • How much Pressure will Remote Seal Pressure Transmitter Indicate?
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
Impulse Piping standards for Field instruments
Pressure Gauge Calibration according to Standard DKD-R-6-1
How Measurement Span of Pressure Gauge Could be Changed?
Differential Pressure Switch Principle
What is a Submersible Pressure Transmitter? Principle, Advantages
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Strain Gauge Pressure Transducer

Resistance Type Pressure Transducers Principle

Gauge Display Scale

How to Read Gauge Analog Scales

Impulse Line Pressure Testing Procedure

Impulse Line Pressure Testing Procedure

Semi Conductor or Piezo Resistive Strain Gauge Principle

Semi Conductor or Piezo Resistive Strain Gauge Principle

Impulse Line Problems

What are Impulse Lines? – Impulse Line Problems & Solutions

Diaphragm seal for pressure measurement device

When to use a Diaphragm Seal?

Principle of Elastic diaphragm gauges

Elastic Diaphragm Gauge Principle

Pressure Gauge Installation

Pressure Gauge Installation at Pump Discharge

More Articles

Standard Test Signals Objective Questions

Standard Test Signals Objective Questions

Counter Count Down Bit

Down Counter PLC Program

Problem on Water Filter Discharge Pressure Transmitter and Gauge

Problem on Water Filter Discharge Pressure Transmitter and Gauge

Control Systems Questions & Answers

Control Systems Objective Questions & Answers – Set 1

butt weld end Plug Valves Leaks Stopped

PTFE lined 6” 300# butt weld end Plug Valves Leaks Stopped Forever

Siemens TIA Portal program blocks

Tia Portal – Optimized and Standard Data Block Access

Difference between TCP-IP Model and OSI Model

Difference between TCP/IP Model and OSI Model

gas chromatograph principle

Online Gas Chromatograph Principle

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?