Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: How Nuclear Radiation is used to Measure Coke Dust Level?
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Practical Questions > How Nuclear Radiation is used to Measure Coke Dust Level?

How Nuclear Radiation is used to Measure Coke Dust Level?

The level of coke dust inside the bin is measured by a gamma radiation nuclear instrument and how it works?

Last updated: January 18, 2021 7:46 pm
Editorial Staff
Practical Questions
No Comments
Share
1 Min Read
SHARE

A coke calcining operation (where petroleum coke is burned to decrease its hydrogen content) uses a large bin to collect coke dust that forms around its hooded conveyor systems.

The level of coke dust inside this bin is measured by a gamma-radiation instrument:

Gamma Radiation Level Instrument

How Nuclear Radiation is used to Measure Coke Dust Level

1. Explain how this system uses nuclear radiation to measure coke dust level?

2. Why does this system use multiple radioactive sources? Why do you suppose one is not sufficient?

3. Suppose some radioactive material accidently entered the storage bin along with coke dust. Would this shift the level instrument’s zero, the span, or both?

4. Identify some alternative technologies which we could use to measure the coke dust level.

5. What function does a cyclone separator perform, based on an analysis of this simple process flow diagram?

Note: cyclone separators are commonly used in sawmill operations, to handle wood chips in a moving air stream.

Share your answers with us through below comments section.

Read Next:

  • Transmitter 5 Way Manifold
  • Distillation Tower Level
  • Tank Pressure Transmitter
  • Level Measurement Lab
  • Level Sensor Specifications

Credits: Tony R. Kuphaldt

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
Fisher model 546 I/P transducer
Current-to-Pressure Transducer Calibration Table
Identify the Purpose of Flow Ratio Controller
Determine the Temperature of 3 Wire RTD
A Series of False Pressure Alarms
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Inductive proximity switches

How to Connect Proximity Switch (Sink Type) to Make LED ON ?

Differential Pressure Transmitter with 5 Way Manifold Valve

Differential Pressure Transmitter with 5 Way Manifold Valve

process conditions, Find out the Circuit Components Status

As per Process Conditions, Find out the Circuit Components Status ?

Calibration setup for a low-range electronic pressure transmitter

Instrument Lab Exercise – Ranging and Manometer Usage

pressure switches relay circuit

Determine the functions of Pressure Switches ?

Flow Transmitter Readings mismatch with DCS

Flow Transmitter Readings mismatch with DCS

Hydraulic Actuated Lift

Oil and Air Pressure Actuated Lifts Questions

Process Switches Normal Status

Define Normal Status for each of the Process Switch

More Articles

PLC Program for Positive edge pulse output for one scan cycle

PLC Program for Positive Edge Pulse Output for One Scan Cycle

piping for a Different pressure flow transmitter

Impulse Piping standards for Field instruments

Ideal Diode Characteristics Curve

Difference between ideal diode & conventional diode

Instrumentation Loop Diagram

Loop diagram and System Inspection Lab Exercise

Process Pressure Measurement Objective Questions

Process Pressure Measurement Objective Questions

Stability in Frequency Domain

Mathematical Preliminaries

PlantPAx DCS

Introduction to PlantPAx Distributed Control System

HVAC System Heat Transfer Loops

Heat Transfer Loops in HVAC System

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?