Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Interview Questions and Answers on Load Cell
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Instrumentation Interview Questions > Interview Questions and Answers on Load Cell

Interview Questions and Answers on Load Cell

Last updated: September 28, 2022 2:38 pm
R Jagan Mohan Rao
Instrumentation Interview Questions
No Comments
Share
11 Min Read
SHARE

This post shares the top 25 technical questions and answers on the load cell used in the industrial weighing applications.

Contents
Load Cell QuestionsWhat is a load cell?What is the principle of electrical strain gauge load cells?What is the gauge factor?What is excitation voltage in strain gauge load cells?What is the sensitivity of the load cell?How do I convert load cell output voltage to kilograms?What is bonded strain gauge load cells?What makes strain gauge load cells to use in industrial applications?What is a Wheatstone’s bridge? and strain gauge load cell cable color assignment?How can compensate temperature in Wheatstone’s bridge?How the Load cell designs can be distinguished?What types of load cells are there?How load cells are classified according to the type of output signal?How load cells are classified according to the type they detect weight?Where do Pneumatic load cells use particularly?Where do Hydraulic load cells are used particularly?What are the applications of Hydraulic load cells?What is the principle of Pneumatic load cells?What are the advantages of Pneumatic load cells?What are the disadvantages of Pneumatic load cells?What are the applications of load cells?What is the Load cell accuracy, sensitivity among Pneumatic, Hydraulic, Strain gauge, and Capacitance type?How the load cells are connected for personal scales or multipoint weight sensors?What is the calibration procedure?What are do’s and don’ts with load cell usage?

Load Cell Questions

Load Cell Questions

What is a load cell?

A load cell is a transducer that converts force into measurable electrical output quantity. Although there are many varieties of load cells, strain gage based load cells are the most commonly used type in all industrial applications.

Strain gage load cells dominate the weighing industry.

What is the principle of electrical strain gauge load cells?

Electrical strain gauges are based on the principle of change of the electrical resistance due to the change in the length of the metal used in the strain gauge. The formula for the resistance of a strain gauge metal is:

R = ρ L/A

Where ρ = resistivity

A = Cross-sectional area

L = Length

What is the gauge factor?

Gauge Factor is defined as the ratio between the unit change in resistance to the per unit change in length.

This can be mathematically written as,

Gf = Δ R / R divided by Δ L / L

Where

Δ R / R = per unit change in resistance

Δ L / L = per unit change in length

Gf = Gauge Factor

But the strain of an elastic material is defined as the per unit change in length, therefore

Strain, ε = Change in metal wire Length / Original Length of metal wire

= ΔL / L

So, Gauge Factor, Gf = ε (ΔR / R)

What is excitation voltage in strain gauge load cells?

The strain gauge load cell is an active transducer. Active transducers can be excited by a controlled current or voltage source. A constant-voltage excitation is used for strain sensors.

What is the sensitivity of the load cell?

It is the ratio between the out voltages to its input, which is loaded at the nominal force.

It is expressed in mV/V which means, it presents the maximum strain applied to the proof body.

How do I convert load cell output voltage to kilograms?

Every load cell comes with a calibration certificate denoting its sensitivity. This sensitivity value can be used to convert the load cell’s output signal to units of weight.

To calculate the raw output voltage of the cell relative to its rated full capacity say 100 Kgs, use the following equation:

Vout = S * VExt

The Vout = Output voltage of the load cell

S = Sensitivity

VExt = Excitation voltage.

If excitation voltage is 12 V and sensitivity is 2mV/V, the rated capacity of the load cell is 100 Kgs

Vout = 2mV/V x 12

= 24

If excitation voltage is 12 V and sensitivity is 2mV/V, if we apply a load 50 Kgs. The rated capacity of the load cell is 100 Kgs.

Vout = 2mV/V x 12

= 2 / 2 * 12

= 12

What is bonded strain gauge load cells?

Foil strain gauges are bonded on to the load cell sensor bodies using adhesive, glue, and then are connected to Wheatstone bridge arrangement.

What makes strain gauge load cells to use in industrial applications?

Strain gage load cells provide accuracies from within 0.03% to 0.25% full scale and are most suitable for almost all industrial applications.

What is a Wheatstone’s bridge? and strain gauge load cell cable color assignment?

The Wheatstone bridge is a configuration of four balanced resistors. If all resistors are balanced meaning R1/R2 = R3/R4 then Vo becomes zero. If any arm resistance changes, Vo changes.

what is a Wheatstone’s bridge

The most common color assignment is

Red for (Excitation voltage Positive) Exc+,

Black for (Excitation voltage Negative) Exc−,

Green for (Signal Positive) S+,

White for (Signal Negative) S−.

How can compensate temperature in Wheatstone’s bridge?

By using two or four strain gauges in a Wheatstone’s bridge, temperature compensation can be achieved. These are called half-bridge, full-bridge configurations.

Any changes in temperature, effect the same way on all strain gauges if mounted on the same material.

Wheatstone Half bridge Configuration

Wheatstone Full bridge Configuration

How the Load cell designs can be distinguished?

Load cell designs can be identified according to the type of the output signal generated (pneumatic, hydraulic, and electric) or distinguished according to the way they detect weight (bending, shear, compression, tension, etc.).

What types of load cells are there?

There are many different types of load cells, depending on the various applications they are designed for.

Bending beam or shear beam load cells are frequently used, for example, in platform scales.

Compression load cells, on the other hand, are usually installed under structures (containers, silos, Bins, etc.) that are loaded with weight from above and are often designed for higher loads.

In the case of tensile load cells, on the other hand, a weight is attached to the load cell. Load cells are the most important constituent of a scale, be it a platform, floor, or table scale.

Railcar weighing

How load cells are classified according to the type of output signal?

Electrical load cell (Strain gauge load cell)

Pneumatic load cell

Hydraulic load cell

How load cells are classified according to the type they detect weight?

Shear

Bending

Tension

Compression

Where do Pneumatic load cells use particularly?

For maximum exactness, the weight of the tank should be collected by locating one load cell at each point of support and summing their outputs.

Pneumatic load cells are sometimes used where intrinsic safety and hygiene are highly desired.

Where do Hydraulic load cells are used particularly?

Hydraulic load cells are considered most suitable in remote locations, as they do not require a power supply.

What are the applications of Hydraulic load cells?

Typical hydraulic load cell applications include silo, tank, bin, and hopper weighing.

Hydraulic load cells are based on force-balance devices, measuring weight as a change in pressure of the internal filling fluid  0.25% full scale or better, acceptable for most process weighing applications. Because this sensor has no electric components, it is perfect for use in hazardous areas.

What is the principle of Pneumatic load cells?

Pneumatic load cells also work on the force-balance principle.

What are the advantages of Pneumatic load cells?

Explosion-proof

Load cells are Insensitive to temperature variations.

A Pneumatic load cell does not contain any kind of fluids that might contaminate the process if the diaphragm ruptures.

What are the disadvantages of Pneumatic load cells?

Disadvantages of Pneumatic load cell:

The slow speed of response

Requires a clean, dry, regulated air or nitrogen.

What are the applications of load cells?

Force measurement

Portable weigh scales

Platform scales

Electronic weighbridge or truck weighing

Electronic crane scales

Hopper/Tank/Silo weighing

Onboard weighing

What is the Load cell accuracy, sensitivity among Pneumatic, Hydraulic, Strain gauge, and Capacitance type?

From the above figure, we can see that Hydraulic load cells are least accurate, lease sensitive and capacitance load cells are highly accurate, highly sensitive.

Load Cell Accuracy

How the load cells are connected for personal scales or multipoint weight sensors?

Load cells can be connected in parallel.

The output cables of a load cell consist of two power cables (positive/negative), two signal cables (+/-), and one shield cable. There are five cables in total. In that case, all the corresponding output signal cables are joined together (Exc+ to Exc+, S+ to S+ …), and the resulting output signal is the average of the all signals from all the sensing elements.

What is the calibration procedure?

Standard calibration tests will use linearity and repeatability as a calibration guideline as these are both used to find out the accuracy.

In the case of a 60-ton load cell, then specific test weights that measure in 5, 10, 20, 40, and 60 tons increments may be used – A five-step calibration process is usually enough sufficient for ensuring a device is accurately calibrated. Repeating this five-step calibration procedure 2-3 times is recommended for true results.

What are do’s and don’ts with load cell usage?

Sudden shock or applying a sudden jerk that exceeds the load cell rated capacity for a long time will damage the load cell. However, with proper usage, maintenance, and protection, the load cell can be used for many years, without any trouble.

Shielding – prevents electrical interference and noise problems.

Reference: Wikipedia

Read Next:

  • History of Instrument Signals
  • Compare Fieldbus & 4-20mA
  • Why 4-20 mA Popular?
  • What is Live Zero in 4-20 mA?
  • Loop Checking of Transmitters
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Industrial Instrumentation Questions & Answers
Questions on Piping and Instrumentation Diagrams
Precision Instruments Interview Questions
Total Organic Carbon Analyzers Questions and Answers
Flow Control Valves Interview Questions
Distributed Control System Interview Questions
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Interview Questions on Fieldbus Communication
Siemens PLC Interview Questions and Answers
SCADA Interview Questions and Answers
Conductivity Analyzers Interview Questions & Answers
Serial Communication Interview Questions and Answers
pH Analyzer Interview Questions and Answers
Electrical & Instrumentation QC Interview Questions
Control Valves Multiple Choice Questions
Instrumentation Project Engineer Interview Questions
Basic Instrumentation Test

Keep Learning

Top 100 Instrumentation Engineering Questions & Answers

Top 100 Instrumentation Engineering Questions & Answers

Measuring Instruments Questions and Answers

150+ Measuring Instruments Questions and Answers

Valve Technician Interview Questions

Valve Technician Interview Questions

Field Instrumentation Interview Questions and Answers

Field Instrumentation Interview Questions and Answers

Instrumentation Standards Questions & Answers

Instrumentation Standards Questions and Answers

Instrumentation Lab Viva Questions

Instrumentation Lab Viva Questions

Modbus Communication Interview Questions and Answers

Modbus Communication Interview Questions and Answers

PLC Engineers Interview Questions

PLC SCADA Engineers Interview Questions and Answers

Discover More

OPC Communication Interview Questions Answers

OPC Communication Interview Questions and Answers

pn-junction-with-depletion-layer

How a PN Junction Formed in a Diode

Electrical & Electronics Measurements Objective Questions

Electrical & Electronics Measurements Objective Questions – Set 2

Liapunov’s Stability Analysis

Liapunov’s Stability Criterion – Part I

Use of Regions in SCL Language

Use of Regions in SCL Language

spiral bourdon tube

Bellows, Diaphragms and Bourdon Tubes

PLC Automation for Product Weighing and Labeling

PLC Controlled Conveyor and Weighing with Labeling Automation

PLC analog input scaling

PLC Analog Input Scaling

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?