Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Why Turndown Ratio is important when Selecting a Flow Meter?
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Flow Measurement > Why Turndown Ratio is important when Selecting a Flow Meter?

Why Turndown Ratio is important when Selecting a Flow Meter?

Turndown ratio is a flow measurement term that indicates the range of a specific flow meter is able to measure flow with acceptable accuracy.

Last updated: November 2, 2023 11:10 am
Editorial Staff
Flow Measurement
2 Comments
Share
5 Min Read
SHARE

Turndown ratio is a flow measurement term that indicates the range of a specific flow meter that is able to be measured with acceptable accuracy.

Contents
Why Turndown Ratio is important?Example #1Example #2Typical turndown ratio of various meter types

The turndown ratio refers to the width of the operational range of a device and is defined as the ratio of the maximum capacity to minimum capacity.

For example, a device with a maximum output of 10 units and a minimum output of 2 units has a turndown ratio of 5. The term is commonly used with measurement devices and combustion plants like boilers and gasifiers.

Why Turndown Ratio is important?

Flow meter Turndown Ratio

In flow measurement, the turndown ratio indicates the range of flow that a flow meter is able to measure with acceptable accuracy. It is also known as rangeability. It is important when choosing a flow meter technology for a specific application.

If a gas flow to be measured is expected to vary between 100,000 m³ per day and 1,000,000 m³ per day, the specific application has a turndown ratio of at least 10:1. Therefore the meter requires a turndown ratio of at least 10:1.

For example: if the meter had an advertised maximum flow of 2,000,000 m³ per day then the required turndown ratio would be 20:1.The turndown ratio of each type of meter is limited by theoretical considerations and by practical considerations.

For example, orifice meters create a pressure drop in the measured fluid proportional to the square of the velocity. Therefore the range of differential pressure can become too large and compromise accuracy. It can also create process problems such as hydrate formation, and in the case of measuring the discharge of a compressor, there is a limit to how much pressure loss is acceptable.

Turndown ratio can be expressed as

TR = Q (max) / Q (min)

Where

TR = Turndown Ratio

Q (max) = Maximum Flow

Q (min) = Minimum Flow

Example #1

If a gas to be measured varies between 100000m3/day and 1000000m3/day.

This specific application has a TR = 10:1.

The flow meter required should have a TR of at least 10:1

If the flow meter had a maximum flow of 2000000 m3/day then the required turndown ratio (TR) would be 20:1

Example #2

Consider a 12’’ ruler graduated to a quarter of an inch. Since the smallest distance that could be measured is ¼’’

The turndown ratio is 12’’/ 0.25’’ = 48   i.e, (48:1)

If the same ruler all the graduated lines below 2’’ are smudged, then in this case the turndown ratio would now be 12’’ / 2’’ = 6 (6:1)

Note;

  • Turndown Ratio is one of a number of considerations when choosing or sourcing for a flow meter for your application
  • TR of a flow meter is mostly affected by the devices signal-to-noise ratio (S/N Ratio) which results from the fluid dynamics of the technology and the type of sensor employed.

Typical turndown ratio of various meter types

The examples are here for gas flow, but the same meter types can be used on liquids as well, with similar turndown ratios. Note that meter manufacturers state their products’ turndown ratios—a specific product may have a turndown ratio that varies from the list below.

A Thermal Mass Flow Meter has a turndown ratio of 1000:1.

An orifice plate meter has a practical turndown ratio of 3:1.

A Turbine Meter has a turndown ratio of 10:1.

Rotary positive displacement meters have a turndown ratio of between 10:1 and 80:1, depending on the manufacturer and the application. Diaphragm meters are considered to have a turndown ratio of 80:1.

Multipath ultrasonic meters often have a stated turndown ratio of 50:1.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Scaling Sensor into PLC
  • Turbine Flow Meter
  • Multimeter & Megger
  • Flow meter Scaling
  • Flow Meter Calibration
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Turbine Flow Meters Troubleshooting
Rotary Abutment Flow Meters Working Principle and Animation
Phase Watcher Multiphase Flow Meter (MPFM) Procedure
Different Flow Measurement Technologies
Turbine Flow Meter Installation Procedure
What is a Vortex Flow Meter?
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
2 Comments
  • Bipin Chaudhari says:
    September 3, 2019 at 12:21 pm

    Thanks!
    It’s always imp to check the turndown ratio of flow meters!

    Reply
  • Neetesh Narkar says:
    December 1, 2019 at 2:04 pm

    Still, I am confused in 10:1, means what is 10 indicates & 1 like 10 means 10m3 variation in a day or anything else

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Orifice Plate Tapping – Orifice Plate Taps
Overview of Positive Displacement Flow Meters
Top Questions on Bernoulli’s Principle in Flow Meters
V Cone Flow Meter – Principle, Advantages, Disadvantages
Magnetic Flowmeter vs. Turbine Flowmeter – Comparison
What is a Flow Element? – Types, Comparison of Flow Elements
Flow Instruments – Selection, Principle & Application
Gas and Liquid Measurement: Processes and Solutions for the Industrial Sector

Keep Learning

Venturi Flow Meter

Venturi Flow Meter – Working Principle, Advantages, Animation

Paddle Wheel Flow Meter

Paddle Wheel Flow Meters – Principle, Advantages, Limitations

Interferometer Principle

Interferometer Principle

Location of Pressure Taps

Design Considerations of Orifice Plate

Piston Type Flow Meter Principle

Types of Variable Area Flow Meters

Square-Root extraction in DCS or Transmitter

Square-Root in DCS or Flow Transmitter?

What is Averaging Pitot Tube

What is an Averaging Pitot Tube? – Principle, Advantages

difference between invasive and non-invasive and intrusive and non-intrusive

Difference between Invasive, Non-invasive, Intrusive & Non-intrusive

Learn More

Temperature Transmitter Foundation Fieldbus Configuration

Foundation Fieldbus Temperature Transmitter Configuration

Diaphragm seal for pressure measurement device

When to use a Diaphragm Seal?

Pressure Manometer

Types of Manometers

Instrumentation Deliverables Generated from 3D Modeling

Instrumentation Deliverables Generated from 3D Modeling

AI Technology in Video Surveillance

Next-Generation Security Surveillance Systems – AI Technology

Electrical Machines Questions and Answers

Electrical Machine Multiple Choice Questions

Sequencer Output in PLC

PLC Sequencer Instruction with Example

Types of Cables

Types of Cables, Purpose, Advantages, Disadvantages, Applications

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?