Reading: Pressure Switch Calibration Procedure
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Calibration > Pressure Switch Calibration Procedure

Pressure Switch Calibration Procedure

Last updated: October 21, 2019 4:13 pm
Editorial Staff
Calibration Pressure Measurement
13 Comments
Share
5 Min Read
SHARE

Pressure switches are commonly used in the process industry for a wide range of applications. A pressure switch is a form of sensor that closes or opens an electrical contact when a certain pressure has been obtained either through a pressure rise or a pressure drop.

Contents
Pressure Switch CalibrationCalibration or Verifying a Pressure SwitchRequired Tools:Calibration Procedure :

Pressure switches are used to monitor, control, or provide a caution or warning for a pressure related process. The repeatability, accuracy, and functionality of a pressure switch often tie directly into the safety or efficiency of a process and thus it becomes important that pressure switches are verified and calibrated to ensure their proper function in the process.

Pressure Switch Calibration

There are several terms that describe the function of a switch which need to be understood when testing a pressure switch:

Set point:

The pressure which the switch will change state.

 Normal State:

The state of the switch when at barometric pressure or ideal state.

Depends on Pressure switch type.(typically it would be either OPEN or CLOSED).

Reset:

The pressure at which the switch resets back to the normal state.

Tolerance:

The allowable variation from the set point pressure.

Repeatability:

The closeness of agreement between the results of consecutive measurements.

Dead Band:

The pressure difference between the change-of-states.

(i.e. OPEN to CLOSE or CLOSE to OPEN).

Trip Type:

This is the direction to which the change-of state should happen.

If the trip type is low, this means the change-of-state happens when the pressure is falling.

If the trip type is high, this means the change-of-state happens when the pressure is rising.

Calibration or Verifying a Pressure Switch

Pressure Switch Calibration Procedure

Before implementing the steps, you need to confirm the setpoint and the dead-band of the Pressure switch. In addition, The pressure switch must be depressurized and isolated.

Consider our Pressure Switch is a normally open switch, so we will need to test when the switch changes between open to close. Next, we’ll test the reset pressure (from closed to open) and lastly, repeat the test at least once to determine repeatability.

Required Tools:

  1. we must use a pressure calibrator or Multimeter (DMM) to determine the current state of the switch.
  2. we need to have a pressure generation device (preferably a hand pump ).
  3. we will need a way to measure the true pressure using a pressure calibrator or Pressure gauge.

Calibration Procedure :

  1. First we connect the pressure gauge and Pressure switch to the hand pump as shown in above figure.
  2. Then we need to measure the present status (NO/NC) of electrical output of the switch with the multimeter.Put multimeter in Continuity mode.
  3. Note: Here in this example our pressure switch considered is Normally open type. So when you connect the multimeter before calibration we have default Normally Open (NO) signal as output.
  4. With our connections complete, we are ready to perform the calibration. We do this by increasing pressure until we detect a change in the switch.
  5. Now increase the pressure with the help of hand pump.
  6. When we see the switch change state from open to close, we record the result.
  7. Next, we decrease the pressure till we see the switch reset (change from close to open) and record the results.
  8. Also record the dead band.
  9. Lastly, we would repeat this test at least once to determine repeatability. The difference between set point and rest pressures is the dead
    band.The dead band must be within the range. The deadband & setpoint of pressure switch available on nameplate of pressure switch.
  10. For Normally closed Pressure switch calibration also follows the same above mentioned procedure. But the default status of Normally closed type Pressure switch will have N.C. signal as output. When testing with increasing pressure the output state changes from N.C. to N.O and while on decreasing pressure the output state changes from N.O. to N.C. Remaining all steps are same. Thats it. very simple.
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Different Types of Temperature Calibrators
Hierarchy of Calibration Organizations
Open Tank DP Level Transmitter Calibration
Electrical Standards
Solenoid Valve Functional Testing
How to Calibrate the Eddy Current Conductivity Meter?
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
13 Comments
  • Toubro says:
    September 24, 2015 at 11:05 am

    Thanks for sharing with us. It clearly explained pressure switch calibration and its working.

    Reply
  • mayur says:
    October 7, 2015 at 1:11 pm

    Its a superb website..pls make an app for windos……and make videos free download..

    Reply
    • S Bharadwaj Reddy says:
      October 8, 2015 at 2:36 pm

      Noted.

      Reply
  • Desmond says:
    November 20, 2015 at 7:41 am

    Thanks. It was clearly noted and well understood.

    Reply
  • khurshid alam says:
    November 23, 2015 at 1:57 pm

    Sir, this is very useful site. Plz provide calibration videos.

    Reply
  • Ramakrishnan. says:
    December 7, 2015 at 7:27 am

    fantastic info!

    Reply
  • Riyanto says:
    December 8, 2015 at 4:09 am

    I’m so often use this web as a reference works…thank’s sir for accessing free your web.

    Reply
  • manikandan says:
    February 21, 2016 at 5:56 pm

    I really like this all, its is very useful my carrier, thank u so much…

    Reply
  • Suresh says:
    July 24, 2016 at 12:43 pm

    Sir can u explain pressure switch calibration procedures raising and falling conditions while we r doing calibration…..

    Reply
  • azar says:
    August 8, 2016 at 12:13 pm

    thank u sir, its easy to simple way clearly you mentioned procedure

    Reply
  • azar says:
    August 8, 2016 at 12:14 pm

    Pls sent pressure transmitter calibration procedure sir

    Reply
  • ricado says:
    October 26, 2016 at 1:16 pm

    thanks u for this info. u guys are good. thanx

    Reply
  • WonKi Kim says:
    June 29, 2017 at 5:45 pm

    thanks a lot , I really appreciated.

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Calibration : Up-tests and Down-tests
All About Instrumentation Impulse Lines
How to Create Calibration Records?
Fine Wire Strain Gauge Principle
Diaphragm Seal Transmitters Errors
Information on the Pressure Gauge Dial
Uncertainty Calculations of Pressure Calibration
Current to Pressure (I/P) Converter Calibration Procedure

Keep Learning

Yokogawa differential pressure transmitter

Basics of Differential Pressure Transmitters

Pressure gauge mechanism

How Measurement Span of Pressure Gauge Could be Changed?

Pressure Measurement Interview Questions

Interview Questions on Pressure Measurement

Pressure Gauge with Syphons

Pressure Gauge Syphons Principle

Calibration of Temperature Sensor with Indicator

Calibration of Temperature Sensor with Indicator

Reliability Centered Maintenance (RCM)

What is Reliability Centered Maintenance? (RCM)

Pressure Transmitter

Pressure Transmitter Animation

Fieldbus Pressure Transmitter Configuration

Foundation Fieldbus Pressure Transmitter Configuration

Learn More

Coriolis Mass Flow meter as a Multi Variable Transmitter - 1

Coriolis Mass Flow Meter as a Multi-Variable Transmitter

displacer level transmitter cylindrical weighs

Displacer Level Transmitter 5-point Calibration

Analyzers Questions and Answers

Silica Analyzer Questions & Answers

Auto Changeover Switch

What is an Auto Changeover Switch?

How To Choose A Surge Protector?

How To Choose A Surge Protector?

Calculate Resistance from Temperature for RTD

RTD Calculator : Calculate Resistance from Temperature

Tungsten Grinders

How to Choose the Best Tungsten Grinders for Welders?

Industrial Plasma Systems

Why PDMS is Used For Fabrication?

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?