Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Metal Seated Valves and Soft Seated Valves : Differences
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Control Valves > Metal Seated Valves and Soft Seated Valves : Differences

Metal Seated Valves and Soft Seated Valves : Differences

Last updated: March 21, 2019 3:19 pm
Editorial Staff
Control Valves Guest Articles
No Comments
Share
7 Min Read
SHARE

Metal Seated Ball Valves

Engineered to excel in the most demanding industrial settings where valve deficiencies can endanger safety, plant efficiency and reduce profitability, metal seated ball valves stand out.

Contents
Metal Seated Ball ValvesMetal Seated Valves vs. Soft Seated ValvesAdvantages of Metal Seated Ball ValvesSoft Seated Ball ValvesMetal Seated Valves Coating OptionsMetal-Seated Ball Valve CostsInstallationThe Series 370 Metal Seated ValveType AType BType C

These long-lasting valves are perfect for the oil and gas industries, refining and power generation.

Metal Seated Valves vs. Soft Seated Valves

Deciding on the right seat material can be a difficult decision when it comes to ball valves because you’ll have several options.

Determining factors you will need to consider include the materials used in construction, the appropriate size, and the type of design features including V-port, bleed, double bock, 1, 2, or 3 pieces, etc. An even more important consideration is the seat type.

Having a complete understanding of the process conditions should be the starting point when it comes to choosing seated valves.

  • Does your situation require a bubble tight shut off?
  • Is the fluid corrosive?
  • Does it contain abrasive particulates?
  • Will it be under high pressure or temperatures?

Once you have a firm grasp on these factors, the choice will be apparent.

Advantages of Metal Seated Ball Valves

The key advantage of metal seated valves when compared to soft seated valves is that they can withstand high temperatures and severe service conditions.

Metal seats can stand up to extreme flashing, hydraulic shock, abrasive process fluid, and high temperatures up to and exceeding 1,000° F. They are also ideal for high erosion or corrosion applications.

Another important factor is that metal seats can be hardened by specialized coatings.

Soft Seated Ball Valves

Soft seats are typically composed of thermoplastic components like PTFE. These valves are appropriate for applications in which chemical compatibility is crucial, and in situations where having the tightest seal is important.

Soft seats, however, aren’t suitable for processing abrasive or dirty fluids. These valves are known to break down under conditions like these, resulting in a leaky valve. Complications introduced by soft seated valves are related to the fact that they don’t stand up to applications that challenge their service limits.

Metal seated ball values on the other hand can hold up under high temperatures and extreme service conditions. Well established in the field, metal seated ball valves deliver uninterrupted service with the maximum shut off standards.

The valves also work for longer time periods than soft seated valves. These durable valves can basically handle the majority of abrasive applications.

Also Read : Basics of Ball Valves

Metal Seated Valves Coating Options

With metal to metal seating, and depending on the service conditions, applying various coatings make it possible for ball and seat rings to be hard faced on sealing locations.

Examples of these specialized coatings include satellite hard facing, chromium carbide, tungsten carbide and electrolysis nickel plating. Sealing is achieved by the metal-to-metal contact in between two hard coated surface areas.

Metal-Seated Ball Valve Costs

Even though metal seated valves are more expensive, the cost of downtime resulting from failure, coupled with the replacement of soft seated valve break downs, should be factored in.

The efficiency and longevity of metal seated ball valves will pay off and counteract the higher price.

Bottom line, metal seated ball valves are the best, long lasting, economical options for critical applications.

Installation

The installation of metal seated valves can comply with shut off standards which include ANSI/FCI 70-2-1976 and designed for allowed leakage.

The most frequently specified leakage classes include Class V and VI. Class VI is often misinterpreted as “bubble tight.”

In fact, a certain amount of leakage is permitted, measured by the amount of air bubbles that escape per minute during testing. “Bubble tight” shut-off is more accurately related to resilient-seated valves.

The Valtorc offers best metal seated ball valves with unique features. The below are the details of their product.

The Series 370 Metal Seated Valve

When it comes to metal seated ball valves, the Series 370 is a good example. This series is offered in sizes that range from 1/4″ to 4”, with threaded (NPT) or flanged connection ends.

Advantages of Metal Seated Ball Valves

Manufactured from premium quality 316 stainless steel, this metal valve also has pressure ratings as high as 2000PSI. Another important aspect is that it provides the ISO 5211 mounting pad intended for actuation.

There are three available configurations, including type A, B and C, described as follows.

Type A

This configuration features the conventional metal seat, showcasing polymeric seat seals, body seals, in addition to stem packing.

Metal Seated Ball Valves Type A

The Type A configurations are designed for use in highly erosive and abrasive applications where higher temperatures aren’t in use.

Type B

Utilizing a downstream metal seat, this configuration is a metal seat that incorporates flexible, die-formed graphite seat seals along with stem packing.

Metal Seated Ball Valves Type B

This configuration increases the temperature capacities of metal seated ball valves.

Type C

Similar to Type B, the Type C configuration uses a downstream metal seat, along with an upstream seat, spring loaded against the to assist in downstream.

Metal Seated Ball Valves Type C

This configuration is ideal for higher temperature gasses & fluids and for saturated steam at 720PSIG.

The metal seated ball valves include the following characteristics.

  • Available in flanged or threaded connection ends, in sizes that range from 1/4″ to 4″.
  • For this configuration, the service temperature limitation is 450°F (232.2°C).
  • Configurations include metal seat with body seals polymeric seat seals, stem packing.
  • The body seal is spiral wound flexible/SS316 graphite (flexible/die-formed graphite).
  • Intended usage is in erosive and/or abrasive applications in which higher temperatures aren’t a concern.
  • The polymeric seals incorporated in this metal seat configuration are replaced with flexible, die-formed graphite seat seals with stem packing.

Recognizing your process condition is critical when it comes to choosing the appropriate seat for your specific application.

If you determine that the best solution is metal seated ball valves you’ll find them to be long lasting, cost effective solutions for critical applications.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
What is Gate Valve ?
Solenoid Valve Troubleshooting Practices
What is Stop Check valve ?
Valve Materials Comparison Notes
How to Protect Pumps from Cavitation? – Reasons, Solutions
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Special Control Valves

Special Control Valves

Direct Acting Control Valve Positioner

Pneumatic Valve Positioner Working Principle

Analyzer Sampling System

Gas Analyzer Sampling System

Ball Valve Material Selection

Ball Valve Material Selection

Difference between Globe Valve and Gate Valve

Difference between Globe Valve and Gate Valve ?

Emergency ShutDown Valve Working Principle

ESDV : How it Works ?

Shaft and Coupling Bore Tapers Repair Caused Frequent Shutdowns

Shaft and Coupling Bore Tapers Repair Caused Frequent Shutdowns

control valve parts

Common Terms Used in Control Valves

More Articles

Float & Dial Level Gauge Principle

Float & Dial Level Gauge Principle

Cooling Tower Fans Frequently Failing

Cooling Tower Fans Frequently Failing

cable-trays-glossary

Cable Trays Glossary

Ash Handling System in Thermal Power Plant

Ash Handling System in Thermal Power Plant

What is a Database Server

What is a Database Server? – Types, Comparison

Digital Pressure Gauge Animation

Air Pressure Inside the Tank

Studio 5000 Define Program or Operator Control in Functional Block Diagram

Studio 5000: Define Program or Operator Control in Functional Block Diagram

Major issues for Sensors Selection

Major issues for Sensors Selection