Reading: Displacer Level Transmitter Question & Answer
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Practical Questions > Displacer Level Transmitter Question & Answer

Displacer Level Transmitter Question & Answer

Last updated: September 20, 2018 11:59 am
Editorial Staff
Practical Questions
No Comments
Share
2 Min Read
SHARE

Displacer Level Transmitter

Question :

The principle of buoyancy may be used to create a level transmitter instrument, generating an output signal proportional to the change in weight of a “displacer” rod suspended in a liquid:

buoyancy level transmitter

Often, the displacer is housed inside its own “cage” for easy removal from the process, as shown above, or it may be inserted directly into the process vessel like this:

displacer level transmitter problems

If the vessel is open and the liquid inside is turbulent due to mixing or other agitation, a stilling well serves the same purpose as a cage:

stilling well for level transmitter

To calibrate such an instrument, it must be isolated from the process liquid. Sometimes this means simply closing block valves and draining the cage. Other times it means removing the displacer mechanism from the vessel entirely. But once the displacer is hanging dry, there is the problem of simulating a 100% condition for calibration purposes.

Describe a way to make the displacer “think” it is fully submerged in process liquid when it in fact is hanging freely in the air. Explain how you would be able to precisely and accurately simulate this condition, as well as any given condition of partial displacer submersion for that matter.

Answer :

One way to simulate a full condition is to use a hand scale:

displacer level transmitter Dry Calibration

Also Read : Displacer Level Transmitter Dry Calibration Procedure

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Draw a ladder logic circuit for the electric motor of an air compressor ?
Pressure Transmitter Re-Range Questions
Questions on DP Transmitter Wet Leg Compensating Impulse Line
How Measurement Span of Pressure Gauge Could be Changed?
Determine the Problems with Level Transmitter and Gauge
Calculate the Thermocouple’s Measurement Junction Temperature
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

A Question on Density Gauge
Moving Pressure Sensing Level Transmitter from Top to Bottom
Solenoid Valves Practical Problems
Compressor Emergency Shutdown Root Cause Analysis
Pneumatic Level Transmitter Value Struck?
Practical Process Control System Questions & Answers – 9
Upgrading the Electrical System in an Automobile
What Effect on Hydrostatic Level Transmitter if Liquid Density Changes?

Keep Learning

Determine the statuses of all lamps and relay coils in the circuit

Determine the Status of Lamps and Relays in the Circuit ?

liquid level Measurement

Hydrostatic Level Measurement – Temperature related Density Change Effects

PLC Questions - 1

Sketch a Ladder Diagram for PLC to Energize the Lamp

Suppose the lamp refuses to light up

Indentify Faults in Simple Lamp Circuit including Failed Wires

Allen-Bradley PLC Program

Troubleshoot Allen Bradley PLC Logic

Two solenoid valves circuit

Solenoid Valves Questions & Answers – 4

PLC Programming Questions

PLC Programming Question & Answer

Calibration setup for a low-range electronic pressure transmitter

Instrument Lab Exercise – Ranging and Manometer Usage

Learn More

PID Controller Functions

PID Controller Functions

11 kV, 3.3 kV, and 400 V systems insulation resistance (IR) Problems

11 kV, 3.3 kV, and 400 V systems insulation resistance (IR) Problems

Thermocouples Burnout detection

Thermocouples Burnout detection

Electric Circuits Objective Questions

Electric Circuits Objective Questions – Set 4

Fundamental Motion Control Commands

Fundamental Motion Control Commands

A span error with wrong slope

Determine the Instrument Calibration Error

PLC Ladder Logic Example

PLC Ladder Logic Example

Ball Valve Parts

What is Ball Valve ?

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?