Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: How to Select a Directional Valves
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Instrumentation Design > How to Select a Directional Valves

How to Select a Directional Valves

Last updated: March 18, 2017 6:15 am
Editorial Staff
Instrumentation Design
No Comments
Share
4 Min Read
SHARE

Top 5 Things You Need to Know When Selecting Directional Valves

Selecting the right valve to control system pressure, direction of flow and rate of flow is crucial when designing fluid power circuitry. Below are the top 5 things that must be considered when specifying directional valves for any pneumatic application.

Selecting Directional Valves

1. Function
Directional valves are used to control fluid direction within a pneumatic circuit. The action required by your application will determine the type of valve needed.

  • 2-way valves are only used to allow or stop fluid flow, providing a simple on and off function in a pneumatic circuit.
  • 3-way valves feature three passages within a valve body which are used to pressurize and exhaust a port. These valves are primarily used to operate single-acting actuators such as spring-return cylinders.
  • 4-way valves are one of the most commonly used pneumatic components for directional control. With four distinct flow paths, these valves make it easy to reverse the motion of a cylinder or motor.

2. Actuator Style
Depending on your application requirements, a variety of methods are available to actuate a directional valve.

  • Manual controls include push buttons and detented or momentary toggles.
  • Ball and pin (plunger) style operators are ideal for mechanical actuation.
  • Solenoid operators are used as an interface to convert electrical signals into pneumatic functions.
  • Air pilot operators are ideal for using air pressure to actuate a directional valve at a remote location.

3. Flow Rate
How much flow do you need at the output port of the valve? It is important to know the required flow rate of your application in order to correctly size a directional control valve. If the valve is too big for the application, you will be wasting air & money. If it’s too small, the actuator will not function properly.

Flow rate is typically measured in standard cubic feet per minute (scfm) passing through a valve at a specified operating pressure (psi). Another common measurement is standard cubic feet per hour (scfh).

4. Operating Pressure
The pressure required to operate a directional valve is known as the operating pressure (psi). Since operating pressure greatly affects flow rate, it is important to review the performance data presented by the manufacturer to ensure that a valve will perform as required in your application. For example, at 50 psi a valve can have a flow rate of 9 scfm whereas at 125 psi, the same valve has a flow rate of 20 scfm. Most pneumatic valves are rated for use with vacuum (26” Hg) to 150 psi.

5. Media Compatibility
When using any media other than air, it is important to review the materials of construction to ensure that the internal components and seals are compatible with the fluid passing through the valve.

Also Read: How to Select a Solenoid Valve

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Detail Design Engineering Competency Aspects
Instrumentation Engineer in Process Plant Project
15 Loop Diagram Questions
Instrument Numbering Philosophy
DCS Controllers to Output Current Loops
Turbine-Compressor System Architecture
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

What is Material Take Off (MTO)? – Purpose, Components, Uses
Why We use Shielded Cable and Twisted Pair Cables ?
Instrumentation Engineer Activities & Documents – Detail Design Phase
Instrument Air Compressor Control Philosophy
NACE Standards – MR0103 Vs MR0175
Instrument Process Datasheet (IPDS)
Types of Cables, Purpose, Advantages, Disadvantages, Applications
Thermowell Design Guidelines

Keep Learning

P&ID Interlock Document

Process Control & Safety Systems Logics Implementing Cycle

Explain operation of the circuit

Explain Operation of the Lamp Circuit ?

Cable screen shall not be grounded

Cable Screen shall not be Grounded at Field Device ?

Solenoid Valves Selection Guidelines

Solenoid Valves Selection Guidelines

Determine the statuses of all lamps and relay coils in the circuit

Determine the Status of Lamps and Relays in the Circuit ?

Panel Ground Noise

Floating Vs. Grounded Voltage

Basics of Thermistors, Thermocouples and RTD's

Basics of Thermistors, Thermocouples and RTD’s

Switch or Transmitter

Switch or Transmitter

Learn More

PLC program Permissive Circuit

PLC Electric Motor Interlocks

AC generator Voltage Regulators

AC Generator Voltage Regulators

circuit breaker principle

What is a circuit breaker ?

PLC Program Example on Multiple LEDs using Set Coil

PLC Program Example on Multiple LEDs using Set Coil

process chemical analyzer calibration

Automated Calibration

Gas Detection Excel Converters

VFD Interview Questions and Answers

VFD Interview Questions and Answers – Electrical Drives

Time Response Analysis

Effect of Adding a Zero to a System

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?