Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Special Designs of Ion Selective Electrodes Questions & Answers
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Special Designs of Ion Selective Electrodes Questions & Answers

Special Designs of Ion Selective Electrodes Questions & Answers

Last updated: November 27, 2021 5:38 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
4 Min Read
SHARE

Special Designs of Ion Selective Electrodes Questions & Answers

1. Which of the following gas permeable membrane is used for ammonia gas sensing electrode?

a) Silicon rubber
b) Microporous Teflon membrane
c) Fluorocarbon
d) Polythene

Answer: c

Explanation: Gas permeable membrane used for ammonia sensing electrode is fluorocarbon membrane. For each gas different membranes are used.

2. Which of the following gas permeable membrane is used for carbon dioxide gas sensing electrode?

a) Silicon rubber
b) PVC membrane
c) Fluorocarbon
d) Polythene

Answer: a

Explanation: Gas permeable membrane used for carbon dioxide sensing electrode is silicon rubber membrane. For each gas different membranes are used.

3. The response time of biocatalytic membrane electrode is poor when used with complex organic molecules.

a) True
b) False

Answer: b

Explanation: The response time of biocatalytic membrane electrode is good even when used with complex organic molecules. But, the membrane is costly.

4. Which of the following reference electrode is placed in the solution of carbon dioxide electrode?

a) Calomel electrode
b) Silver/silver chloride electrode
c) Mercury/mercury sulphate electrode
d) Glass electrode

Answer: b

Explanation: A silver/silver chloride reference electrode is placed in the solution. A glass electrode is also placed in the solution but it is not a reference electrode.

5. Biocatalytic membrane electrode cannot be used for the measurement of which of the following gases?

a) Ammonia
b) Carbon dioxide
c) Hydrogen
d) Nitrogen

Answer: d

Explanation: Biocatalytic membranes cannot be used for the measurement of nitrogen. It can be used for the measurement of other three gases.

6. The biocatalytic membrane used in ammonia selective electrode is which of the following?

a) Urea
b) Urease
c) Acrylamide
d) Polyacrylamide

Answer: b

Explanation: The biocatalytic membrane used in ammonia selective electrode is urease. It is used for the detection of ammonia.

7. Which of the following materials are used as gel to which biocatalytic membrane is fixed in ammonia selective electrode?

a) Urea
b) Urease
c) Acrylamide
d) Polyacrylamide

Answer: c

Explanation: The material used as gel to which biocatalytic membrane is fixed in ammonia selective electrode is acrylamide. This is attached to the ion selective electrode directly.

8. The biocatalytic membrane is attached to the glass electrode using which of the following materials?

a) Nylon mesh
b) Teflon
c) Silicon rubber
d) Polythene

Answer: a

Explanation: The biocatalytic membrane is attached to the glass electrode using nylon mesh. Cellophane film can also be used.

9. The response time of the biocatalytic electrode is a function of thickness of the enzyme layer.

a) True
b) False

Answer: a

Explanation: The response time of the biocatalytic electrode is a function of thickness of the enzyme layer. It is also a function of diffusion of the layer in the sample solution.

10. In carbon dioxide electrode, the membrane separates which of the following?

a) Sodium carbonate, magnesium chloride
b) Magnesium hydrogen carbonate, sodium chloride
c) Sodium hydrogen carbonate, sodium chloride
d) Magnesium carbonate, magnesium chloride

Answer: b

Explanation: In carbon dioxide electrode, the membrane separates sodium hydrogen carbonate and sodium chloride. Sodium hydrogen carbonate is the internal electrolyte.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Controller Components – Part 2 Objective Questions
Atomic Absorption Spectroscopy Questions & Answers
Ion Selective Electrodes Questions and Answers
Electron Spectroscopy for Chemical Analysis
Direct Method & Constructing of Liapunov for the Linear & Non-Linear System
Liapunov’s Stability Criterion – Part II
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Performance Indices
Assessment of Relative Stability Using Nyquist Criterion
X-Ray Absorption Meter Questions and Answers
Optimal Control Problems – Part 2
Polar Plots MCQ
Sensivity Enhancement for NMR Spectroscopy Questions & Answers
Preliminary Considerations of Classical Design
Electron Spin Resonance
Permit to Work System Online Test
Tandem Mass Spectroscopy

Keep Learning

Analytical Measurement Multiple Choice Questions

Analytical Measurement Multiple Choice Questions

Ion Spectrometers Questions & Answers

Instrumentation for Electron Spectroscopy

Analyzers Questions and Answers

Biosensors Questions & Answers

Mass Spectrometer Questions and Answers

Gas Chromatograph- Mass Spectrometer

Pollution Monitoring Instruments Questions and Answers

Carbon Monoxide Questions & Answers

Process Control Questions & Answers

Process Control Questions & Answers

Stability in Frequency Domain

Cascade Compensation in Frequency Domain

Flow Measurement Multiple Choice Questions

Flow Measurement Multiple Choice Questions

Discover More

level control system

Practical Process Control System Questions & Answers – 10

Linear Heat Detector Working Principle

What are Linear Heat Detectors?

Coriolis Mass Flow meter as a Multi Variable Transmitter - 1

Coriolis Mass Flow Meter as a Multi-Variable Transmitter

Basic Process Control System

Basic Process Control System

Transistors Questions & Answers

Transistors Questions & Answers

Shutdown Motors in Timed Operation PLC Program

Shutdown Motors in Timed Operation PLC Program

Digital Electronics Objective Questions

Digital Electronics Objective Questions – Set 9

Pressure Detection Circuit

Pressure Detection Circuit

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?