Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Capacitor Filter Working Principle
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Electronic Devices & Circuits > Capacitor Filter Working Principle

Capacitor Filter Working Principle

Last updated: October 4, 2016 10:07 am
Editorial Staff
Electronic Devices & Circuits
1 Comment
Share
2 Min Read
SHARE

A half-wave rectifier with a capacitor-input filter is shown in Below Figure. The filter is simply a capacitor connected from the rectifier output to ground. RL represents the equivalent resistance of a load. We will use the half-wave rectifier to illustrate the basic principle and then expand the concept to full-wave rectification.

During the positive first quarter-cycle of the input, the diode is forward-biased, allowing the capacitor to charge to within 0.7 V of the input peak, as illustrated in Figure (a). When the input begins to decrease below its peak, as shown in part (b), the capacitor retains its charge and the diode becomes reverse-biased because the cathode is more positive than the anode. During the remaining part of the cycle, the capacitor can discharge only through the load resistance at a rate determined by the RLC time constant, which is normally long compared to the period of the input. The larger the time constant, the less the capacitor will discharge. During the first quarter of the next cycle, as illustrated in part (c), the diode will again become forward-biased when the input voltage exceeds the capacitor voltage by approximately 0.7 V.

capacitor-filter

(a) Initial charging of the capacitor (diode is forward-biased) happens only once when power is turned on.

capacitor-filter-principle

(b) The capacitor discharges through RL after peak of positive alternation when the diode is reverse-biased. This discharging occurs during the portion of the input voltage indicated by the solid dark blue curve.

capacitor-filter-working-principle

(c) The capacitor charges back to peak of input when the diode becomes forward-biased. This charging occurs  during the portion of the input voltage indicated by the solid dark blue curve.

Fig : Operation of a half-wave rectifier with a capacitor-input filter. The current indicates charging or discharging of the capacitor.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Zener Diode Voltage Regulator Operation
Bridge Rectifier Working Animation
Center Tapped Full Wave Rectifier Operation
Difference between ideal diode & conventional diode
Forward Bias & Reverse Bias of a Diode
Cathode Ray Tube (CRT)
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
1 Comment
  • Noor Mustafa says:
    October 4, 2016 at 6:35 pm

    useful

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Testing a Transistor with a Digital Multimeter
Basics of Voltage Regulators
Permanent Magnet Moving Coil Instruments (PMMC)
Insulators, Conductors and Semiconductors
Power MOSFET Safe Operating Area
Series and Parallel Resistors
Optocouplers Working Principle
Why Silicon is preferred over Germanium ?

Keep Learning

Comparison of CB, CE & CC Amplifiers

Comparison of Transistor Configurations

What is a Memristor

What is a Memristor? Principle, Advantages, Applications

working-of-pnp-transistor

Working of NPN Transistor

principle of time base generator

Time Base Generator

diode-clamper-circuit

Diode Clampers Principle

Transistors Questions & Answers

Transistors Questions & Answers

Fluorescent Screen of CRT

CRT Fluorescent Screen

diode-clamper-circuit

Full Wave Voltage Doubler using Diodes

Learn More

Thermocouple Temperature Measurements Errors

Thermocouple Temperature Measurement Errors

Compare Serial and Parallel Communication

Difference Between Serial and Parallel Communication

Basic Temperature Sensors MCQ

Basic Temperature Sensors MCQ Questions Answers

Online and Diagnostics of Siemens PLC

How to Use Diagnostic Buffer for SIEMENS PLC?

Difference Between AIS and GIS Panels

Difference Between AIS and GIS Panels

Ion Spectrometers Questions & Answers

Ion Spectroscopy Questions & Answers

number-systems-questions-answers

Number Systems Questions & Answers

PLC control 4 machines with 1 button

CX-Programmer Tutorial: 1 Button To Activate 4 Different Machines

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?