Practical Questions

How much Pressure is applied to Inclined Water Manometer?

Inclined Water Manometer

Question 1:

How much pressure, in inches of water column, is being applied to this inclined water manometer to displace water 5 inches along the length of the tube, inclined at an angle of 30o from horizontal? Assume a negligible change in liquid level inside the “well” throughout the measurement range of the instrument:

Pressure Calculation for Manometers

Answer:

Applied pressure = 2.5 ”W.C.

What matters in manometer calculations is the vertical height difference between the two liquid columns. Inclining one or more of the tubes only causes the liquid to displace further along the tube(s); it does not change the vertical height necessary to balance the applied pressure.

Thus, with a 30o inclined tube, a liquid displacement of 5 inches along the length of the tube equates to one-half that (sin 30o = 0.5). Therefore, the applied pressure is 2.5 inches of water column.

Note that the inclined manometer makes very sensitive pressure measurements possible using standarddensity liquids such as water! Great care, though, must be taken in ensuring the instrument is level (that the inclined tube is at precisely the angle it should be).

Question 2:

How much pressure, in inches of water column, is being applied to this inclined water manometer to create a total displacement of 14 inches along the length of the tubes, inclined at angles of 20o from horizontal?

Assume the base of this manometer is located 24 inches above ground level.

Next, convert this pressure into units of kPa

Answer:

Applied pressure = 1.193 kPa

More Questions:

1. Identify which fundamental principles of science, technology, and/or math apply to each step of your solution to this problem. In other words, be prepared to explain the reason(s) “why” for every step of your solution, rather than merely describing those steps.

2. Does inclining a manometer make it more or less sensitive to applied pressure? Develop a “thought experiment” where you could test a manometer to answer this question.

3. Is it possible to make a well version of an inclined manometer so that we need only to read one liquid column?

4. What will happen to a manometer if it is exposed to a gas pressure greater than its measurement range?

5. Would a micromanometer be more or less sensitive to applied pressure than this inclined manometer?

Share your Answers with us through comments.

Read Next:

Credits: Tony R. Kuphaldt

You've successfully subscribed !
Share

Recent Articles

  • PLC Tutorials

Example of Flip-Flop PLC Program for Lamps Application

Learn the example of flip-flop PLC program for lamps application using the ladder logic to…

4 days ago
  • PLC Tutorials

STAR DELTA Programming using PLC Controller

In this article, you will learn the STAR DELTA programming using PLC controller to start…

4 days ago
  • Instrumentation Design

Single and Three Phase Immersion Electrical Heaters Wiring Circuits

Lube oil consoles of rotary equipment packages in industrial process plants are usually equipped with…

1 day ago
  • Instrumentation Design

Immersion Heaters in Lube Oil Consoles

Rotating equipment packages such as pumps, compressors, turbines need the lube oil consoles for their…

3 days ago
  • PLC Tutorials

How to Blink Lights in Ladder Logic?

This article explains how to blink lights in ladder logic with a detailed explanation video…

3 weeks ago
  • PLC Tutorials

From Boolean Algebra to PLC Logic

In this article, a simple example will teach you the conversion from Boolean algebra to…

1 month ago