Categories: Instrumentation Design

How to Select a Pressure Gauge

Seven Steps to Select a Pressure Gauge

1. ACCURACY

Pressure Gauge Accuracy

For a mechanical pressure gauge, accuracy is defined as a percentage of the full-scale range. While requirements differ from one industry to another, the following are general guidelines:

• Test Gauges and Standards: 0.25% through 0.10% full scale accuracies.

• Critical Processes: 0.5% full scale accuracy.

• General Industrial Processes: 1.0% accuracy. Less Critical Commercial Uses: 2.0% accuracy.

Refer to ASME B40.100 for more information on accuracy.

2. DIAL SIZE

Pressure gauge dial sizes range from less than 1˝ to 16˝ diameters. Generally, readability require- ments, space limitations and required gauge accuracy determine dial size. Accuracies of 0.25% or 0.5% generally have dial sizes of 41 ⁄2˝ or larger since more dial graduations are required.

3. CASE STYLE / MATERIAL

Environmental considerations include ambient temperature, air-borne particulate, condensation, humidity, water and chemicals, all of which can affect gauge performance.

Ambient temperature may affect the accuracy and integrity of the gauge. Gauges are available either temperature compensated or non-temperature compensated. Ambient conditions may require that the gauge be isolated from temperature extremes. When required, the gauge should be isolated from temperature extremes with a flexible line assembly.

When ambient conditions are corrosive, contain a large number of particulate or if the gauge will be exposed to a wet or humid environment like humidity, wash-downs or rain, specify a gauge that is weatherproof/hermetically sealed or liquid filled.

4. MEDIA / WETTED PARTS

The wetted parts of the pressure gauge, the Bourdon tube and socket must be compatible with the process media. If not compatible with the wetted parts of the gauge, corrosion will occur. Corrosion of gauge wetted parts will eventually cause gauge failure and possibly safety issues. When the gauge wetted parts are not compatible with the process media, a diaphragm should be considered.

5. CONNECTION SIZE

Gauges are available with a variety of connections including NPT, DIN, JIS, BSP & SAE. Process pressure gauges with 41 ⁄2˝ dial sizes or larger are most often supplied with a 1 ⁄2˝ NPT connection to best support the gauge. Factors to consider when selecting a pressure gauge connection include process pressures, gauge size and weight, space limitations, leak integrity, and past experience.

6. CONNECTION LOCATION

Consider the following mounting options when selecting a pressure gauge:

• Stem mount lower connect

• Wall/surface mount lower connect

• Panel mount back connect

• U-clamp flush mount back connect, for panel mounting

• Front flange flush mount back connect, for panel mounting

7. PRESSURE RANGES

ASME B40.100 recommends that normal operating pressure be confined to 25%-75% of the scale. If pulsation is present in the process, maximum operating gauge pressure should not exceed 50% of the full-scale range.

CONCLUSION

To properly select a pressure gauge, consider the gauge process, range, environment, accuracy, dial size, connection and mounting requirements.

Also Read: Working Principle of Pressure Gauge

You've successfully subscribed !

View Comments

Share

Recent Articles

  • Instrumentation Design

Immersion Heaters in Lube Oil Consoles

Rotating equipment packages such as pumps, compressors, turbines need the lube oil consoles for their…

3 days ago
  • PLC Tutorials

How to Blink Lights in Ladder Logic?

This article explains how to blink lights in ladder logic with a detailed explanation video…

3 weeks ago
  • PLC Tutorials

From Boolean Algebra to PLC Logic

In this article, a simple example will teach you the conversion from Boolean algebra to…

1 month ago
  • PLC Tutorials

PLC Cooking Timer Example for Kitchen Automation

In this article, you will learn the PLC cooking timer example for kitchen automation using…

3 weeks ago
  • PLC Tutorials

Example PLC Program to Control a Pump based on Level Sensors

Learn an example PLC program to control a pump based on level sensors using ladder…

3 weeks ago
  • PLC Tutorials

PLC Timer Application in Security Camera Recording

In the PLC timer application for security camera recording, when motion is detected then camera…

3 weeks ago