Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Fire Dampers in Fire Protection
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Fire & Gas System > Fire Dampers in Fire Protection

Fire Dampers in Fire Protection

Learn how fire dampers prevent the spread of fire and smoke in HVAC systems and ensure compliance with fire safety codes in buildings.

Last updated: May 8, 2025 1:43 pm
Viral Nagda
Fire & Gas System
No Comments
Share
6 Min Read
SHARE

In buildings, fire protection is a must. Big buildings and industrial premises mostly have HVAC systems in them for air ventilation, cooling, or heating purposes. If fire catches in such systems, then it spreads immediately and causes large-scale destruction, due to air circulation or air blockage. To prevent this, a device called a fire damper is deployed in HVAC systems to protect against the spread of fire. The whole concept is to keep the fire confined to its origin point and prevent it from spreading. This work is done properly with the help of fire dampers. In this post, we will see the use of fire dampers in fire protection.

Contents
What is a fire damper?Operation of the fire damper

What is a fire damper?

Refer to the below image. Imagine you have an AHU or air handling unit system installed in your plant that supplies cool air to various zones. The zones are interconnected in such a way that cool air passes through various zones. If fire catches somewhere, then this fire would spread through all the zones as air would aid it’s passage.

Fire Dampers in Fire Protection

To block this, we installed a fire damper in the path. In the event of a fire, the damper will close and block the flow of fire through it. So, the installation of fire dampers depends on their usage. If you find that a particular zone itself is combustible and can catch fire at any time due to usage inside, then you can install a fire damper in such a way that it prevents fire from spreading from that zone, instead of blocking fire from the air duct.

How much time the fire damper can withstand fire depends on its ratings. It usually comes on an hour basis; this means it can withstand either for an hour or even up to 6 hours and maintain its structural and physical integrity. So, do not get confused by that term when you choose the fire damper for your application.

Fire dampers can then be used with other safety systems like water sprinklers or fire extinguishers in tandem or conjunction, which help to quickly prevent the fire from spreading throughout the whole premises like a wildfire. Also, fire dampers are different from smoke dampers; do not get confused thinking both are the same. A smoke damper will detect even smoke, which makes it quicker to prevent the fire from spreading. A fire damper, on the other hand, will detect actual fire, which will be very hot and high in temperature.

Fire dampers are mainly classified based on air pressure, which can be low, medium or high. Based on the air pressure, the construction of the fire damper varies, which helps the user to properly select the damper based on your application.

Operation of the fire damper

Fire Damper

As we saw earlier, a fire damper detects fire and closes. So, how does it work? A fire damper has flaps, which normally remain open to allow the air in under proper conditions. It will be installed near ducts or return/supply air plenums near the rooms (as discussed, it entirely depends on your requirement), either vertically or horizontally. The fire damper can be operated either in a passive way or electrically controlled.

Let us first discuss the passive method. It has a fusible link, which melts when the temperature becomes too high. In that event, the link will melt, which will trigger a return spring to close the flaps immediately. This is thus entirely a mechanical action. It remains closed until manually reset by the user by first changing this link. Now, in the electrical method, the damper is controlled by a controller. The controller will take feedback from a fire sensor, and when it senses, it will command the actuator of the fire damper to close.

In any case, the damper will not open automatically. It needs to be reset manually by the user after asserting that the fire has been extinguished from the system. It will then again come back to operation. Fire dampers also come in various international standards of NFPA (National Fire Protection Association) and UL (Underwriter’s Association), which helps the user to understand the specifications and their safety compliance and regulations. The fire damper needs to be installed in such a way that it is easy to access for maintenance. So, before the start of construction of the HVAC system, the engineers need to carefully consider their placement, so that any untoward incident is further prevented when the system is running.

In this way, we saw the role of fire dampers in fire protection.

Read Next:

  • What is a Gas Leak Detection System?
  • Negative Readings in Gas Detector
  • Heat Detector Testing Procedure
  • Fire Pump – Definition, Principle
  • Rate Compensated Heat Detector

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Fire and Gas System Loop Checks Procedure
Infrared Gas Detectors Working Principle
Basics of Fire Detection and Alarm System
What is a Fusible Plug? – Working, Advantages, Disadvantages
Chlorine Gas Hazards
Fire Fighting System
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Fire Water Spray Systems Principle
What is an FACP? (Fire Alarm Control Panel)
Fire and Gas System Interview Questions & Answers
Smoke Detector Testing Procedure
Deluge System for Transformer Protection Animation
Rate Compensated Heat Detectors Working Principle
Importance of Fire & Gas Detection System
What is Manual Call Point (MCP) ?
Sensor Technologies in Gas Detectors
Argonite Fire Suppression System Working Principle

Keep Learning

Fire and Gas (F&G) Mapping: Methodology, Performance Targets, Acceptance Criteria

Design Basis for Fire Detection and Alarm System

Design Basis for Fire Detection and Alarm System

Carbon Monoxide Gas Detector

Carbon Monoxide Gas Sensor Principle

Rate of Rise Thermal Detectors Working Principle

Rate of Rise Thermal Detectors Working Principle

Factors for Setting Alarm Levels on Toxic Gas Detectors

Factors for Setting Alarm Levels on Toxic Gas Detectors

Catalytic-Bead-Sensor-2

Gas Detectors Working Principle

Deluge Valve Operation using Solenoid Valve Animation

Deluge Valve Operation

Sprinkler System

Basics of Sprinkler System

Discover More

Types of Cable Lengths in Ethernet Network

Types of Cable Lengths in Ethernet Network

What is a Dosing Pump? - Types, Advantages, Applications

What is a Dosing Pump? – Types, Advantages, Applications

Digital Electronics Multiple Choice Questions

Read Only Memory (ROM) Objective Questions – Part 3

Troubleshooting Fieldbus Devices

Troubleshooting Fieldbus Devices

Transparent Level Gauge

Level Indicators Working Principle

Transmitter Proof Testing

Transmitter Proof Testing

Safety Instrumented System Engineer Interview Questions

Safety Instrumented Systems Online Exam

Electrical Machines Questions and Answers

Induction Machines Multiple Choice Questions

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?