Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Single-acting Pneumatic Cylinder Operation with Limit Switch
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > PLC Tutorials > Single-acting Pneumatic Cylinder Operation with Limit Switch

Single-acting Pneumatic Cylinder Operation with Limit Switch

Learn the single-acting pneumatic cylinder operation with limit switch based feedback for the open and close status signals.

Last updated: January 23, 2024 11:22 am
Editorial Staff
PLC Tutorials
No Comments
Share
7 Min Read
SHARE

In industry, there are many applications in which we use limit switches. Here we have one limit switch, and we want to operate a single-acting cylinder with a limit switch.

Contents
Single-acting Pneumatic CylinderExplanationCylinderValveLimit SwitchApplicationsAdvantages

So, the limit switch is connected in series with the single-acting cylinder. So, the requirement is that we want to operate a single-acting cylinder when the limit switch is pressed and close when the limit switch is not pressed.

Single-acting Pneumatic Cylinder

Single-acting Pneumatic Cylinder operation with Limit Switch

Circuit Description:

As per the diagram here, we have connected the limit switch in the series with the single-acting cylinder. So once the limit is pressed the air flow will go from A to port to cylinder and after that cylinder will move.

In the above circuit, we connected one single-acting cylinder in a pneumatic line series. Pneumatic air will be connected to the P port and the cylinder line relates to the A port of the 3/2 DCV. R is the exhaust port form where the air will be exhausted. Here the limit switch is a 3/2 valve. 

Explanation

In this application, we want to learn how a limit switch works in the pneumatic circuit. In this application, as shown in the figure one limit switch (a1) relates to single-acting cylinder A via a pneumatic line or tube.

So once the limit switch is pressed by some object then air will move from P to A so it will push the cylinder piston outside, it is called the cylinder extracted condition. In another way, if the limit switch is released or the object is not in contact then Air will be exhausted from A to R It is called the cylinder retracted.

Put more simply, the single-acting cylinder can be triggered when the limit switch is pressed, completing the electrical circuit. Depending on the design and needs of the application, this activation may result in the cylinder extending or retracting.

On the other hand, the electrical circuit is open and the single-acting cylinder cannot operate when the limit switch is not pressed.

Components:

Cylinder

With their ability to provide regulated linear motion using the force of air or hydraulic fluid, single-acting cylinders are essential to automation.

Because of their single port design for fluid entry and external force design for the return stroke, they can be used in a variety of applications that call for dependability and simplicity.

Valve

The setup entails incorporating an air (or hydraulic) supply, a control valve, a single-acting cylinder, and a limit switch into the system. The limit switch is positioned so that, when pressed, it will cause the piston rod to extend.

When the single-acting cylinder extends to the required length, it stops on its own.

The single-acting cylinder’s return stroke is started by the control system upon releasing the Limit Switch (a1), concluding the cycle.

After an automatic reset, the single-acting cylinder is prepared for the subsequent operation.

Limit Switch

A limit switch connects an electrical circuit and a mechanical action or position. Limit switches fall into one of two categories:

Many kinds are based on the arrangements for contacts. It is activated when a piston rod, workpiece, or machine part is in a specific position. Typically, a cylinder piston or cam influences operation.

A limit switch provides two distinct events, the making of one contact and the breaking of the other. Limit switches are normally changeover contacts and can be used in three connection forms.

  • A normally closed contact (N/C)
  • A normally open contact (N/O)

Applications

Applications for this control arrangement can be found in many different industries, including assembly lines, manufacturing, and automated operations that call for accurate and controlled linear movements. Limit switch functioning is easy enough for operators of various ability levels to understand.

Door open-close application: – In industry doors, the open-close application is common, we can use this simple mechanism to implement it with a cost-effective solution.

Object sensing application: – In industry, there are several applications where objects need to touch the limit switch and the operation will start in that kind of operation, we can use this simple mechanism. 

Advantages

This is a completely pneumatic system so it’s safe for the hazardous area. In some industrial applications and environments electric signals are not allowed due to hazardous zones so there we can implement this type of system.

We can use this system for door open-close systems where electrical signal is not allowed. Here we need completely pneumatic energy in the form of air so there is no need for an electrical supply. A compressor will supply air to the cylinder and cylinder movement will happen with pneumatic energy.

Air is used in this application, so it is clean and safe. In the case of the hydraulic system, there is a chance for oil leakage so it may impact the environment. The surrounding area becomes dirty due to oil and dust.

Oil will spoil the surrounding area so maintenance will increase for the components, and the time needed to clean components, so dust is also harmful to electronic components.

If you liked this article, then please subscribe to our YouTube Channel for Electrical, Electronics, Instrumentation, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • How to Select a Directional Valves?
  • How to Choose a PLC for a Project?
  • Moving Data between Siemens PLCs
  • Proximity Switch Working Animation
  • Free Cylinder Valve Sizing Calculator
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

PLC Compressor Control Ladder Logic
Allen Bradley PLC ControlLogix Hardware
Drilling Process using PLC Program
Free Download Programmable Logic Controller (PLC) Book
PLC Program Examples
Auto and Manual Liquid Tank System: PLC Program Example
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

What is Interposing Relay in a PLC System ?
PLC Example on Manufacturing Line Assembly
PLC Timer Application in Security Camera Recording
How to Start Writing SCL Language in Siemens Tia Portal?
Automatic Door Operation PLC Programming and Simulation
Edge Detection in PLC Programming
Anti-static Wrist Straps in Industrial Automation
SCADA Communication and Protocols

Keep Learning

Safety interlock for motor starters in Siemens PLC

Motor Starter Logic using Siemens PLC Tia Portal

PLC XOR LOGIC with Ladder Diagram

PLC Logic Functions

On Delay Timer using PLC

ON Delay Timer using PLC

Omron PLC Car Parking Program

OMRON PLC Tutorial: Car Parking System Application

Best Practices of PLC Wiring

Best Practices of PLC Wiring – Programmable Logic Controller

PLC control 4 machines with 1 button

CX-Programmer Tutorial: 1 Button To Activate 4 Different Machines

Two Hand Control Logic

Two Hand Control Logic using PLC

PLC Program for Traffic Light Sequence using Functional Blocks

PLC Program for Traffic Light Sequence using Functional Blocks

Learn More

Gas Detection Excel Converters

Top Electrical Engineering Interview Questions for Freshers

Latest Electrical Motors Questions and Answers

List of Documents Required for Testing and Calibration Laboratory

List of Documents Required for Testing and Calibration Laboratories

Siemens PLC Organization Blocks used For Troubleshooting

Tia Portal – OB121 Programming Errors Interrupt Organization Block

Garage Door Roller Shutter

Shutter Door Control using Motor and Limit Switches

Coil Type Timers in Siemens PLC Programming

Coil Type Timers in Siemens PLC Programming

HART Communication Problems

HART Communication Problems

Water Treatment Plant

Water Treatment Plant

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?