Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Question on Remote Seal with Capillary Tubing Transmitter
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Practical Questions > Question on Remote Seal with Capillary Tubing Transmitter

Question on Remote Seal with Capillary Tubing Transmitter

The DP transmitter is located 5 feet above the bottom of the vessel and has a remote seal with capillary tubing with fill fluid.

Last updated: November 21, 2020 9:34 am
Editorial Staff
Practical Questions
No Comments
Share
2 Min Read
SHARE

The DP transmitter is located 5 feet above the bottom of the vessel and has a remote seal with capillary tubing whose fill fluid has a specific gravity of 1.9.

The following storage vessel holds a liquid with a density of 60 lb/ft3.

Remote Seal with Capillary Tubing Transmitter

Question on Remote Seal with Capillary Tubing Transmitter

The desired level measurement range is 0 feet to 11 feet:

Assuming an electronic transmitter with an output range of 4 to 20 mA, and a calibration accuracy of ± 0.2% of span.

Complete the following calibration table for the transmitter.

Electronic transmitter with an output range of 4 to 20 mA

Now, complete the following calibration table for the level indicator:

calibration table for the level indicator

More Questions:

1. Demonstrate how to estimate numerical answers for this problem without using a calculator.

2. Suppose this vessel were enclosed at the top, and a remote-sealed compensating leg connected from the transmitter’s “L” port to the top of the vessel. How would this change the transmitter’s necessary calibration? Would it require an adjustment in zero, span, linearity, or some combination of these?

3. Given a 100% full vessel, calculate the amount of pressure that would be registered by a pressure gauge connected to the bottom of the vessel.

4. Given a 100% full vessel, calculate the amount of pressure that would be registered by a pressure gauge connected to the capillary tube (at the remote seal).

5. Given a 100% full vessel, calculate the amount of pressure that would be registered by a pressure gauge connected to the capillary tube (at the transmitter “H” port).

Share your answers and explanation with us through the below comments section.

Read Next:

  • Thread Sealant Types
  • Fire and Safety Notes
  • Interposing Relay Panel
  • Control Valve Testing
  • Control Loop Faults

Credits: Tony R. Kuphaldt

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Pressure Transmitter Re-Range Questions
Pneumatic Moment-balance Differential Pressure Transmitter
Problem with Pirani Gauge
Programmable Logic Controller (PLC) Questions and Answers – 12
Define Normal Status of a Process Switch ?
Something is Wrong with Strain Gauge Bridge Circuit
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Programmable Logic Controller (PLC) Questions and Answers – 7
Displacer Level Transmitter Question & Answer
Electric-driven Air Compressor Troubleshooting
Solenoid Valves Questions & Answers – 3
Which Instrument is Faulty? Transmitter, Recorder, or Controller
Transmitter Calibration Range of a Vessel Level
Practical Process Control System Questions & Answers – 7
Practical Process Control System Questions & Answers – 1
Liquid Level Measurement using Pressure Transmitter Questions
Practical Process Control System Questions & Answers – 3

Keep Learning

compressor emergency shutdown system

Compressor Emergency Shutdown Root Cause Analysis

Calculate DPT Calibrated Range

Calculate the Transmitter Values

Level Transmitter trend

Identify Level Control Loop Tuning Problems

Calculation of Hydrostatic Pressure

Calculation of Hydrostatic Pressure

High and Low Ports on Pneumatic DP Transmitter

Identify High and Low Ports on Pneumatic DP Transmitter

Suppose the lamp refuses to light up

Indentify Faults in Simple Lamp Circuit including Failed Wires

Process vessel for measuring water level

Level Measurement Lab Exercise

Two pressure switches

Identify Two Pressure Switches Logic

Discover More

Power Systems Questions & Answers

Power Systems MCQ Series 11

Modbus scan

How Modbus Communication works

controller integral wind-up

Limit Controls : High Limit & Low Limit Functions

Bernoulli's Principle

Bernoulli’s Principle and Equation – Flow Measurement

Control Valves Questions and Answers

Control Valve Questions and Answers

Multiple Pumps Control using PLC

Multiple Pumps Control using PLC

RTD Construction

Introduction to RTDs

Pressure Transmitter Basics

Pressure Transmitter Applications

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?