Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Metric Prefixes and Unit Conversions
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Common > Metric Prefixes and Unit Conversions

Metric Prefixes and Unit Conversions

Last updated: June 9, 2020 1:51 pm
Editorial Staff
Common
No Comments
Share
5 Min Read
SHARE

Metric Prefixes

  • Yotta = 1024   Symbol: Y
  • Zeta = 1021   Symbol: Z
  • Exa = 1018   Symbol: E
  • Peta = 1015   Symbol: P
  • Tera = 1012   Symbol: T
  • Giga = 109   Symbol: G
  • Mega = 106   Symbol: M
  • Kilo = 103   Symbol: k
  • Hecto = 102   Symbol: h
  • Deca = 101   Symbol: da
  • Deci = 10−1   Symbol: d
  • Centi = 10−2   Symbol: c
  • Milli = 10−3   Symbol: m
  • Micro = 10−6   Symbol: μ
  • Nano = 10−9   Symbol: n
  • Pico = 10−12   Symbol: p
  • Femto = 10−15   Symbol: f
  • Atto = 10−18   Symbol: a
  • Zepto = 10−21   Symbol: z
  • Yocto = 10−24   Symbol: y

Metric Prefixes and Unit Conversions

Contents
Metric PrefixesUnit Conversions

Unit Conversions

The below list shows conversions for different units.

Conversion factors for temperature

oF = (oC)(9/5) + 32
oC = (oF – 32)(5/9)
oR = oF + 459.67
oK = oC + 273.15

Conversion equivalencies for volume

1 US gallon (gal) = 231.0 cubic inches (in3) = 4 quarts (qt) = 8 pints (pt) = 128 fluid ounces (fl. oz.) = 3.7854 liters (l)

1 Imperial gallon (gal) = 160 fluid ounces (fl. oz.) = 4.546 liters (l)

1 milliliter (ml) = 1 cubic centimeter (cm3)

Conversion equivalencies for distance

1 inch (in) = 2.540000 centimeter (cm)

1 foot (ft) = 12 inches (in)

1 yard (yd) = 3 feet (ft)

1 mile (mi) = 5280 feet (ft)

Conversion equivalencies for velocity

1 mile per hour (mi/h) = 88 feet per minute (ft/m) = 1.46667 feet per second (ft/s) = 1.60934 kilometer per hour (km/h) = 0.44704 meter per second (m/s) = 0.868976 knot (knot—international)

Conversion equivalencies for weight

1 pound (lb) = 16 ounces (oz) = 0.45359 kilogram (kg)

Conversion equivalencies for force

1 pound-force (lbf) = 4.44822 newton (N)

Conversion equivalencies for area

1 acre = 43560 square feet (ft2) = 4840 square yards (yd2) = 4046.86 square meters (m2)

Conversion equivalencies for pressure

1 pound per square inch (psi) = 2.03603 inches of mercury (in. Hg) = 27.6807 inches of water (in. W.C.) = 6894.757 pascals (Pa) = 0.0680460 atmospheres (Atm) = 0.0689476 bar (bar)

Conversion equivalencies for energy or work

1 british thermal unit (BTU—“International Table”) = 251.996 calories (cal—“International Table”) = 1055.06 joules (J) = 1055.06 watt-seconds (W-s) = 0.293071 watt-hour (W-hr) = 1.05506 x 1010 ergs (erg) = 778.169 foot-pound-force (ft-lbf)

Conversion equivalencies for power

1 horsepower (hp—550 ft-lbf/s) = 745.7 watts (W) = 2544.43 british thermal units per hour (BTU/hr) = 0.0760181 boiler horsepower (hp—boiler)

Acceleration of gravity (free fall), Earth standard

9.806650 meters per second per second (m/s2) = 32.1740 feet per second per second (ft/s2)

Physical constants

Speed of light in a vacuum (c) = 2.9979 × 108 meters per second (m/s) = 186,281 miles per second (mi/s)

Avogadro’s number (NA) = 6.022 × 1023 per mole (mol−1)

Electronic charge (e) = 1.602 × 10−19 Coulomb (C)

Boltzmann’s constant (k) = 1.38 × 10−23 Joules per Kelvin (J/K)

Stefan-Boltzmann constant (σ) = 5.67 × 10−8 Watts per square meter-Kelvin4 (W/m2·K4)

Molar gas constant (R) = 8.314 Joules per mole-Kelvin (J/mol-K)

Properties of Water

Freezing point at sea level = 32oF = 0oC

Boiling point at sea level = 212oF = 100oC

Density of water at 4oC = 1000 kg/m3 = 1 g/cm3 = 1 kg/liter = 62.428 lb/ft3 = 1.94 slugs/ft3

Specific heat of water at 14oC = 1.00002 calories/g·oC = 1 BTU/lb·oF = 4.1869 Joules/g·oC

Specific heat of ice ≈ 0.5 calories/g·oC

Specific heat of steam ≈ 0.48 calories/g·oC

Absolute viscosity of water at 20oC = 1.0019 centipoise (cp) = 0.0010019 Pascal-seconds (Pa·s)

Surface tension of water (in contact with air) at 18oC = 73.05 dynes/cm

pH of pure water at 25o C = 7.0 (pH scale = 0 to 14)

Properties of Dry Air at sea level

Density of dry air at 20oC and 760 torr = 1.204 mg/cm3 = 1.204 kg/m3 = 0.075 lb/ft3 = 0.00235 slugs/ft3

Absolute viscosity of dry air at 20oC and 760 torr = 0.018 centipoise (cp) = 1.8 × 10−5 Pascal-seconds (Pa·s)

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

2-wire Transmitters Current Loops
Difference Between Resistive Touch and Capacitive Touch
Control of Pneumatic Cylinder and Motor
How Technology is Shaping the Future of Education?
Proximity Sensor
Benefits of Pursuing a Degree in Engineering
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Pneumatic Cylinder Movement Control with Timer Circuit
Instruments Troubleshooting – Problems, Causes, Corrective Actions
What is Transparent Solar Panel? – Working Principle and Theory
What is Magnetic Tape Recorder ?
Web Tension Measurement and Control Technologies
Electrification in Mining Industry
Top US Universities that Offer Online Education
What is Cloud Computing? Types of Cloud Services, Components

Keep Learning

Insulation Resistance Test

What is an Insulation Resistance Test? – Types, Applications

List of 100 Sensors and Transducers Questions

List of 100 Sensors and Transducers Questions

Internet of Things Communication Models (IoT)

Internet of Things Communication Models (IoT)

Top 100 Microcontrollers Project Ideas

Top 100 Microcontrollers Project Ideas

Batch Pan Automation in the sugar industry

Batch Pan Automation in the Sugar Industry

Arduino Zero

What is Arduino? Different Models of Arduino Controllers

Modern Instrumentation & IoT: Key Innovations & Trends

Modern Instrumentation & IoT: Key Innovations & Trends

Sugar Industry Logics

Mill Interlocks in the Sugar Industry

Learn More

Pinch Valve

What is Pinch Valve ?

Field Instruments

Is Vacuum affects Field Instruments in Industries?

Steam Turbine Driven Centrifugal Compressors Leak due to Broken Instrument

Discharge Head 3‑monthly leaks of Steam Turbine Driven Centrifugal Compressors

What is Electrical Interlocking?

Electrical Contactor Interlocking Circuit Explained

Lithium-ion Battery Charging System

Lithium-ion Battery Charging Systems

Basic Process Control System

Basic Process Control System

Manchester encoding

Foundation Fieldbus Electrical Parameters

Negative Readings in Gas Detectors

Why Negative Readings in Gas Detectors ?

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?