Reading: How Measurement Span of Pressure Gauge Could be Changed?
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Pressure Measurement > How Measurement Span of Pressure Gauge Could be Changed?

How Measurement Span of Pressure Gauge Could be Changed?

Last updated: June 3, 2020 12:24 pm
Editorial Staff
Pressure Measurement Practical Questions
1 Comment
Share
2 Min Read
SHARE

Shown here is a diagram of a standard pressure gauge, based on the pressure-sensing action of a hollow, C-shaped metal tube called a bourdon tube:

Pressure gauge mechanism

Using arrows, trace the motions of all moving components in this mechanism as an increasing pressure is applied to the fitting at the bottom of the bourdon tube.

Also, describe how the measurement span of this pressure gauge could be changed. In other words, what would have to be moved, adjusted, or altered in this mechanism in order to change the proportionality of applied pressure to pointer movement?

Answer:

The parts in this gauge mechanism would move as such:

motions of all moving components in pressure gauge

Possible things to change to make this pressure-measuring mechanism more sensitive:

  • Decrease the spring rate (“stiffness”) of the bourdon tube
  • Shorted the arm of the sector gear (the portion to the right of the pivot, joining with the link)
  • Increase the sector gear radius
  • Decrease the pinion gear radius

More Questions for you:

1. What sort of device(s) would you suggest using to apply a precisely known pressure to a gauge for calibration purposes?

2. Suppose a pressure gauge is intended for service in a process measuring liquid pressure. Is it okay to calibrate this gauge on a test bench using compressed air instead of the liquid it will be exposed to in the field? Why or why not?

Share your answers with us through below comments section.

Read Next:

  • DeadWeight Tester Questions
  • DP Level Measurement Problem
  • Valve Questions and Answers
  • Pneumatic Load Cell Principle
  • What is a Four-wire RTD?

Credits: Tony R. Kuphaldt

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Programmable Logic Controller (PLC) Questions and Answers – 13
Determine Level of Liquid in the Vessel and its Specific Gravity
How Capacitive Pressure Sensor Works ?
Inclined-limb Manometer Principle
Galileo Thermometer
How to Connect Proximity Switch (Sink Type) to Make LED ON ?
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
1 Comment
  • b demudu says:
    June 29, 2020 at 6:45 pm

    pressure gauge calibrated with air and oil(dead weight tester) with air

    instrumentation air to connect through the air regulator to insincere the pressure then same pressure to indicate the test (calibrated) gauge this type of test method is good and no deviation maximum

    the bourdon tube mainly affected by temperature and also a constant pressure is maintained line for a long time this case also gauges are not responding correctly

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Distillation Tower Displacer Level Instrument Check
Calculation of Hydrostatic Pressure
How to Measure Pressure in Inches of Water Column
Programmable Logic Controller (PLC) Questions and Answers – 16
Practical Process Control System Questions & Answers – 6
Tank uses 3 Pressure Transmitters to Measure Level & Density
Piston Type Differential Pressure Gauge Principle
Programmable Logic Controller (PLC) Questions and Answers – 6

Keep Learning

Problem on Solar Hot Air Collector and Variable Speed Fan

Problem on Solar Hot Air Collector and Variable Speed Fan

Current-to-Pressure Transducer Calibration Table

Ladder Diagram circuit

PLC Practice Questions

Calculate Temperature of Four Wire RTD

Calculate the Temperature of 4 Wire RTD

Two solenoid valves circuit

Solenoid Valves Questions & Answers – 4

Is it Possible to Measure liquid-liquid Level Interface using Float

Is it Possible to Measure Liquid-Liquid Level Interface using Float?

burner management system P&ID

Solenoid Valves Questions & Answers – 1

surface-mounted water pump

Surface-mounted Water Pump

Learn More

PLC Retrofitting Project

What is a PLC Retrofitting Project? – Importance, Procedure

Clamp Meter

What is a Clamp Meter?

Electrical Heating Objective Questions and Answers

Electrical Heating Objective Questions and Answers

AC Generator Operation

AC Generator Theory

Why 4-20 mA Current Signal is used instead of Voltage Signal

Why 4-20 mA Current Signal is used instead of Voltage Signal?

Hydraulic Actuated Lift

Oil and Air Pressure Actuated Lifts Questions

Nano Instrumentation Objective Questions

Nano Instrumentation Objective Questions

PLC Compressor Control Ladder Logic

PLC Compressor Control Ladder Logic

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?