Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Loop Calibrator to Simulate a 4-20 mA Signal
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Control Systems > Loop Calibrator to Simulate a 4-20 mA Signal

Loop Calibrator to Simulate a 4-20 mA Signal

Last updated: February 21, 2020 10:22 am
Editorial Staff
Control Systems
2 Comments
Share
1 Min Read
SHARE

Suppose a technician wishes to use a loop calibrator to simulate a 4-20 mA signal to a controller, and decides to connect the loop calibrator to the circuit like this:

Contents
Loop Calibrator to Simulate a 4-20 mA SignalRead Next:

Loop Calibrator to Simulate a 4-20 mA Signal

Loop Calibrator to Simulate a 4-20 mA Signal

Explain why this is an improper use of the loop calibrator, and what will happen if the technician tries to simulate a 9 mA signal this way. Finally, identify the proper way to use the loop calibrator to simulate a transmitter signal.

Share your answers with us through comments.

Read Next:

  • How to use Loop Calibrator
  • 4–20 mA Control Loops
  • As-Found and As-Left
  • Loop Powered Instruments
  • Loop Checks Transmitters

Credits: Tony R. Kuphaldt

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
Process Control Fundamentals
Control System Architecture
Heuristic PID Tuning Method
Comparison of Proportional Integral Derivative Controllers (PID)
Industrial Automation and Control Systems (IACS)
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
2 Comments
  • saurav kumar gupta says:
    February 13, 2020 at 10:36 am

    The calibrator is not even in closed loop and it is connected as a parallel dc source which will add more mili amps to the instrument additional to the controller mamps supply. Thus the operation of the instrument will be not as expected.

    Reply
  • Vignesh says:
    March 23, 2020 at 1:29 pm

    Once we have simulate the mA values to the DCS with probes directly to the 24v dc cores without the connection in the tx.

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Wellhead Control Panel

Basics of Wellhead Control Panel (WHCP)

PID-Controller-Simulator-graph

PID Controller Tunning Parameters Simulator

Process Dynamics and PID Controller Tuning

Process Dynamics and PID Controller Tuning

PID Controller Responses to Two momentary step inputs

PID Controller Response with different Input Signals

Voice Activated Industrial Automation

Voice Activated Industrial Automation Systems

Integral Wind-Up Limitation

What is Integral Wind Up ?

Levels in Industrial Automation

Five Levels in Industrial Automation

Active Barrier

What is a Active Barrier ?

More Articles

PLC Programmer Tools

Tools Required for PLC Programmer to Carry at Site

Distribution transformer

Types of Transformers

Humming Sound in Transformer

Why is the Humming Sound Produced in Transformer?

3φ AC Power Connections

Three Phase Systems

open vs closed loop

Open Loop and Closed Loop Animation

Safety interlock for motor starters in Siemens PLC

Motor Starter Logic using Siemens PLC Tia Portal

level control system

Practical Process Control System Questions & Answers – 11

Smart Valve Monitoring

SIS Instruments and Valves Inline Testing – Safety Instrumented System

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?