Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Thermowell Outer Diameter Larger than Nozzle Inside Diameter?
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Instrumentation Design > Thermowell Outer Diameter Larger than Nozzle Inside Diameter?

Thermowell Outer Diameter Larger than Nozzle Inside Diameter?

Last updated: December 3, 2019 11:02 am
Editorial Staff
Instrumentation Design Temperature Measurement
1 Comment
Share
4 Min Read
SHARE

A scary part on-site is when you try to install the Thermowell inside the Nozzle and you realize the Thermowell Outer Diameter (OD) larger than Nozzle Inside Diameter (ID)?.

Contents
1. Nozzle Schedule2. Cladding on Thermowell3. Clearance SpaceBeware of illegal WaysAuthor: Asad ShaikhArticles You May Like :

Thermowell Outer Diameter larger than Nozzle Inside Diameter

Image Courtesy: Parker

This simple thing will lead to great delays since you can’t just insert some other thermowell as they go through W.F.C calculations, material selection, etc.

Nobody would want this to happen, so Let’s explore the precautions and recommended practices.

What factors are to be evaluated for ensuring the Thermowell gets properly inserted in Nozzle I.D

1. Nozzle Schedule

Even 1&1/2 inch pipe won’t have the same I.D all the time.

The schedule of the pipe needs to be checked.

As it is logical the Higher the schedule (like Std, XS, XXS etc) the smaller the I.D available.

Software’s like pipe pro can be used to get dimensions.

2. Cladding on Thermowell

Thermowell consumes a lot of material as compared to the diaphragm of transmitters etc.

So always it is not a cost-effective option to upgrade thermowell material to Alloy C-276 or other exotic material until it’s a dire necessity.

Another option sometimes used (depends on application) is to provide cladding on thermowell.

This also consumes little space and must be accounted for.

3. Clearance Space

This one important consideration that gets overlooked.

Handling changes at the initial stages of the project is very easy, but the very same changes at a later stage have a significant impact.

A classic example is Wake frequency calculation that caused the Thermowell base O.D to increase. (Maybe in the later stage process data got revised or WFC was incorrectly done etc)

Now if we have exact cut to cut the distance between nozzle I.D and Thermowell O.D then it is very difficult to accommodate such last-minute changes.

Few more examples are listed below:-

Thermal expansion at higher temperatures is an issue.

As indicated above maybe at a later stage cladding of thermowell is recommended and this will consume some space.

Also sometimes the Pipe spec has a certain schedule but for ease of welling, a different schedule is selected for vessel nozzle.

Hence it is preferred not to take the exact cut to cut the distance and keep some clearance.

Beware of illegal Ways

Polishing of thermowell to fit into the Nozzle:-

Sometimes on-site people polish the thermowell to reduce its O.D so that it fits in the nozzle.

This is an unsafe practice. As this risks the integrity of thermowell design and can lead to catastrophic failure.

Thanks for reading !!

I hope it has been of value to you.

PS: This is as per the best of my current understanding.

Do you face any problems with Thermowells? Share with us.

Author: Asad Shaikh

Profile: Linkedin

Articles You May Like :

  • RTD Troubleshooting Tips
  • Thermowell Insulation Thickness
  • Temperature Interview Questions
  • What is Temperature Scanner?
  • Errors in Thermocouples
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
How to calculate Thermocouple Temperature by measuring the output millivoltage
Solenoid Valve Selection Criteria
Why have been limits imposed on the frequency ratio for thermowells?
Resistance Temperature Detectors Troubleshooting Tips
Thermocouple Construction
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
1 Comment
  • Galih says:
    January 15, 2020 at 8:24 am

    Dear Asad,

    Just additional information, if thermowell design required to add collar it must be also considered with the nozzle ID.

    Thank you,

    Rgds,
    Galih Probo Kusuma

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Process Plant Risk and Safety Management

Safety Roles & Responsibilities of Process Engineering (Detail Design)

Thermocouple Testing

Thermocouple Cold Junction Compensation

RTD Calculator Software

RTD Calculator Software

Effect of Lead Wire Resistance on RTD

Effect of Lead Wire Resistance on RTD

Solenoid Operated Valves and Latching Valves

Solenoid Operated Valves and Latching Valves

Marshalling Panel

What is Marshalling Cabinet?

What is NEST loading in DCS

What is Nest Loading? – DCS and PLC Control Systems

process conditions, Find out the Circuit Components Status

As per Process Conditions, Find out the Circuit Components Status ?

More Articles

VFD circuit

AC Motor Braking

Thermography and Thermometry Objective Questions

Thermography and Thermometry Objective Questions

pH Analyzers Questions and Answers

Combination Electrode Questions & Answers

Temperature Measurement Interview

Temperature Measurement Interview Questions

Encode and Decode Instructions

How to Use Encode and Decode Instructions in PLC ?

Free Online Control Valves Course

Free Control Valves Course

Voltage Regulator Circuit

Basics of Voltage Regulator

Specific-Conductance-Calibration-Procedure

Types of AC Motors and DC Motors

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?