Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Cascade Control Principle
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Control Systems > Cascade Control Principle

Cascade Control Principle

Last updated: December 6, 2019 8:14 pm
Editorial Staff
Control Systems
3 Comments
Share
5 Min Read
SHARE

What is Cascade Control?

In single-loop control, the controller’s set point is set by an operator, and its output drives a final control element. For example: a level controller driving a control valve to keep the level at its set point.

Single Loop Control

In a cascade control arrangement, there are two (or more) controllers of which one controller’s output drives the set point of another controller. For example: a level controller driving the set point of a flow controller to keep the level at its set point. The flow controller, in turn, drives a control valve to match the flow with the set point the level controller is requesting.

Cascade Control

The controller driving the set point (the level controller in the example above) is called the primary, outer, or master controller. The controller receiving the set point (flow controller in the example) is called the secondary, inner or slave controller.

Cascade control can improve control system performance over single-loop control whenever either: (1) Disturbances affect a measurable intermediate or secondary process output that directly affects the primary process output that we wish to control; or (2) the gain of the secondary process, including the actuator, is nonlinear. In the first case, a cascade control system can limit the effect of the disturbances entering the secondary variable on the primary output. In the second case, a cascade control system can limit the effect of actuator or secondary process gain variations on the control system performance. Such gain variations usually arise from changes in operating point due to setpoint changes or sustained disturbances.

When Should Cascade Control be Used?

Cascade control should always be used if you have a process with relatively slow dynamics (like level, temperature, composition, humidity) and a liquid or gas flow, or some other relatively-fast process, has to be manipulated to control the slow process. For example: changing cooling water flow rate to control condenser pressure (vacuum), or changing steam flow rate to control heat exchanger outlet temperature. In both cases, flow control loops should be used as inner loops in cascade arrangements.

Does Cascade Control Have any Disadvantages?

Cascade control has three disadvantages. One, it requires an additional measurement (usually flow rate) to work. Two, there is an additional controller that has to be tuned. And three, the control strategy is more complex – for engineers and operators alike. These disadvantages have to be weighed up against the benefits of the expected improvement in control to decide if cascade control should be implemented.

When Should Cascade Control Not be Used?

Cascade control is beneficial only if the dynamics of the inner loop are fast compared to those of the outer loop. Cascade control should generally not be used if the inner loop is not at least three times faster than the outer loop, because the improved performance may not justify the added complexity.

In addition to the diminished benefits of cascade control when the inner loop is not significantly faster than the outer loop, there is also a risk of interaction between the two loops that could result in instability – especially if the inner loop is tuned very aggressively.

How Should Cascade Controls be Tuned?

A cascade arrangement should be tuned starting with the innermost loop. Once that one is tuned, it is placed in cascade control, or external set point mode, and then the loop driving its set point is tuned. Do not use quarter-amplitude-damping tuning rules (such as the unmodified Ziegler-Nichols and Cohen-Coon rules) to tune control loops in a cascade structure because it can cause instability if the process dynamics of the inner and outer loops are similar.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Flexible Input Output Modules
What is a Control Panel and its types?
Control Systems Interview Questions & Answers
Technical Evaluation for DCS and ESD – Distributed Control System
Serial Communication Error Checking Methods and Algorithms
DCS Alarm Summary Dashboard using Microsoft Power BI
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
3 Comments
  • Akshay says:
    November 6, 2017 at 5:07 pm

    For cascade control above example..there are two controller used.So what are the process Variable and control variable for this two controller ?

    Reply
  • Dheeraj says:
    December 29, 2022 at 9:41 am

    Master Controller’s variable will be work as PV and SV. in the above example Level controller will be the master controller.

    Reply
  • Innocent Menuchimso Bob-Weke says:
    January 28, 2024 at 11:59 pm

    Thanks

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Overview of Split Range Control
Proportional-only Control Theory
PID Controllers : Parallel, Ideal & Series
Example of Feedback System
Foundation Fieldbus Split Range Valves
Cascade Temperature Control System
PID Simulator Download
Free PID Controller Gains Tuning Tool

Keep Learning

Anti Surge Controller Theory

Anti Surge Controller Working Principle

Alarm and Trip Documentation

PLC Alarm and Trip Documentation

Process Automation

What is Process Automation? – Simple Automation Example

PlantPAx Select Add components into Project

How to Import PlantPAx Library?

annunciator-alarm-simulator

Alarm Simulator for Annunciator Logic

Features of PID Controller

Features of PID Controller actions

Basic Control Systems Questions

14 Basic Control Systems Questions for Interview Preparation

Analog inputs in library

Design Process Graphics in Factory Talk View Studio with an Analog Input

Learn More

Instrumentation Engineering Quiz

Instrumentation Engineering Quiz – Set 2

Advantages of HVDC transmission

Advantages of HVDC transmission

OPC Communication Interview Questions Answers

OPC Communication Interview Questions and Answers

Hazardous Area Terminology

Hazardous Area Terminology

Absorption Chiller Principle - HVAC System

HVAC Double Effect Absorption Chiller

Closed-tank-DP-Level-Transmitter-with-wet-leg-elevation-zero-direct-mount-Calibration

Closed tank DP Level Transmitter with wet leg elevation zero direct mount Calibration

Light Tower in Industrial Automation

What is a Tower Lamp? – Light Tower in Industrial Automation

Erratic Radar Level Gauges

Erratic Radar Level Gauges Delays a Refinery Commissioning

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?