Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Discharge and Charging of Lead-Acid Battery
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Electrical Theory > Discharge and Charging of Lead-Acid Battery

Discharge and Charging of Lead-Acid Battery

Last updated: July 27, 2018 6:12 pm
Editorial Staff
Electrical Theory
No Comments
Share
4 Min Read
SHARE

In a lead-acid battery, two types of lead are acted upon electro-chemically by an electrolytic solution of diluted sulfuric acid (H2SO4). The positive plate consists of lead peroxide (PbO2), and the negative plate is sponge lead (Pb), shown in Figure 4.

Lead Acid Battery Discharge

Figure 4 : Chemical Action During Discharge

When a lead-acid battery is discharged, the electrolyte divides into H2 and SO4 combine with some of the oxygen that is formed on the positive plate to produce water (H2O), and thereby reduces the amount of acid in the electrolyte. The sulfate (SO4) combines with the lead (Pb) of both plates, forming lead sulphate (PbSO4), as shown in Equation.

lead-acid battery discharge equation

As a lead-acid battery is charged in the reverse direction, the action described in the discharge is reversed. The lead sulphate (PbSO4) is driven out and back into the electrolyte (H2SO4). The return of acid to the electrolyte will reduce the sulphate in the plates and increase the specific gravity. This will continue to happen until all of the acid is driven from the plates and back into the electrolyte, as shown in below Equation and Figure 5.

Lead Acid Battery charge

Figure 5 : Chemical Action During Charging

lead-acid battery charge equation

As a lead-acid battery charge nears completion, hydrogen (H2) gas is liberated at the negative plate, and oxygen (O2) gas is liberated at the positive plate. This action occurs since the charging current is usually greater than the current necessary to reduce the remaining amount of lead sulfate on the plates. The excess current ionizes the water (H2O) in the electrolyte. Since hydrogen is highly explosive, it is necessary to provide adequate ventilation to the battery whenever charging is in progress. Also, no smoking, electric sparks, or open flames are allowed near a charging battery.

The decrease in specific gravity on discharge is proportional to the ampere-hours discharged. While charging a lead-acid battery, the rise in specific gravity is not uniform, or proportional, to the amount of ampere-hours charged (Figure 6).

Voltage and Specific Gravity During Batteries Charge and Discharge

Figure 6 : Voltage and Specific Gravity During Charge and Discharge

The electrolyte in a lead-acid battery plays a direct role in the chemical reaction. The specific gravity decreases as the battery discharges and increases to its normal, original value as it is charged. Since specific gravity of a lead-acid battery decreases proportionally during discharge, the value of specific gravity at any given time is an approximate indication of the battery’s state of charge.

To determine the state of charge, compare the specific gravity, as read using a hydrometer, with the full charge value and the manufacturer’s published specific gravity drop, which is the decrease from full to nominal charge value.

Example:

A lead-acid battery reads 1.175 specific gravity. Its average full charge specific gravity is 1.260 and has a normal gravity drop of 120 points (or.120) at an 8 hour discharge rate.

Solution:

Fully charged – 1.260

Present charge – 1.175

The battery is 85 points below its fully charged state. It is therefore about 85/120, or 71%, discharged.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
Starting of DC Motors
Low Voltage Air Circuit Breaker Principle
AC Induction Motor Slip
Wattmeter
Synchronous Motors
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Core-Type Transformer

Transformer Turns Ratio

Motor Rotating Magnetic Field

AC Motor Theory

Three-Phase Wye Wiring System

4-Wire, Three-Phase Wye Wiring System

Series Parallel Circuit Analysis

Series – Parallel Circuit Analysis

Simple RL Circuit

Impedance in RL Circuits

4-Wire, Three-Phase Delta Wiring System

4-Wire, Three-Phase Delta Wiring System

Transformer Tap changer

Transformer Mutual Induction

DC Generator

DC Generator

More Articles

Allen-Bradley SLC 500

History of Programmable Logic Controllers (PLC)

DCS Program to Maintain Draft in Furnace

DCS Program to Maintain Draft in Furnace

Process variable to 4-20mA Conversion

Formula to Calculate 4-20 mA from Process Variable

Top 300 Digital Signal Processing Projects (DSP)

Top 300 Digital Signal Processing Projects – DSP Project Ideas

Digital Electronics Multiple Choice Questions

Ring Counter Objective Questions

How to use Fire Fighting Hydrant

Fire and Safety

Sensors and Transducers Test

Sensors and Transducers Test

What to Choose RTD or Thermocouple ?

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?