Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Functions of Pressure Detectors
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Pressure Measurement > Functions of Pressure Detectors

Functions of Pressure Detectors

Last updated: May 23, 2018 11:45 am
Editorial Staff
Pressure Measurement
No Comments
Share
3 Min Read
SHARE

Pressure Detector Functions

Although the pressures that are monitored vary slightly depending on the details of facility design, all pressure detectors are used to provide up to three basic functions: indication, alarm, and control. Since the fluid system may operate at both saturation and subcooled conditions, accurate pressure indication must be available to maintain proper cooling. Some pressure detectors have audible and visual alarms associated with them when specified preset limits are exceeded. Some pressure detector applications are used as inputs to protective features and control functions.

Detector Failure

If a pressure instrument fails, spare detector elements may be utilized if installed. If spare detectors are not installed, the pressure may be read at an independent local mechanical gauge, if available, or a precision pressure gauge may be installed in the system at a convenient point. If the detector is functional, it may be possible to obtain pressure readings by measuring voltage or current values across the detector leads and comparing this reading with calibration curves.

Environmental Concerns

Pressure instruments are sensitive to variations in the atmospheric pressure surrounding the detector. This is especially apparent when the detector is located within an enclosed space. Variations in the pressure surrounding the detector will cause the indicated pressure from the detector to change. This will greatly reduce the accuracy of the pressure instrument and should be considered when installing and maintaining these instruments.

Ambient temperature variations will affect the accuracy and reliability of pressure detection instrumentation. Variations in ambient temperature can directly affect the resistance of components in the instrumentation circuitry, and, therefore, affect the calibration of electric/electronic equipment. The effects of temperature variations are reduced by the design of the circuitry and by maintaining the pressure detection instrumentation in the proper environment.

The presence of humidity will also affect most electrical equipment, especially electronic equipment. High humidity causes moisture to collect on the equipment. This moisture can cause short circuits, grounds, and corrosion, which, in turn, may damage components. The effects due to humidity are controlled by maintaining the equipment in the proper environment.

Summary

The three functions of pressure monitoring instrumentation and alternate methods of monitoring pressure are summarized below.

Pressure detectors perform the following basic functions:

  • Indication
  • Alarm
  • Control

If a pressure detector becomes inoperative:

  • A spare detector element may be used (if installed).
  • A local mechanical pressure gauge can be used (if available).
  • A precision pressure gauge may be installed in the system.

Environmental concerns:

  • Atmospheric pressure
  • Ambient temperature
  • Humidity
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Capacitive Type Pressure Transducers Principle
Pressure Gauge Selection
Gage and Absolute Pressure Transmitters Principle
Basics of Pressure Measurement
Capillary Tubing Pressure Sensor Temperature & Elevation Problems
Pressure Gauges : Remote and Chemical Seals
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Types of Pressure – Instrument Questions and Answers
Comparison of Pressure Instruments – Industrial Instrumentation
Impulse Line Purging and Close Coupling of Instruments
Installation and Calibration of Pressure Transmitter
What is Capillary Tubing? – Advantages and Disadvantages
Pressure Gauges : Common Causes for Failures and Their Effective Solutions
Pressure Switch Calibration Procedure
Diaphragm Seal Material Selection

Keep Learning

Pressure Gauge Accessories

Pressure Gauge Accessories

Submersible Pressure Transmitter

What is a Submersible Pressure Transmitter? Principle, Advantages

Troubleshooting Fluid Systems Pressure Changes

Troubleshooting Fluid Systems Pressure Changes

U tube Manometer Working

Basics of Pressure

Hammer Effect in Gauges

What is Hammer Effect in Gauges ?

Difference between Absolute, Gauge and Differential Pressure Transmitters

Difference between Absolute, Gauge and Differential Pressure Transmitters

Absolute and Gauge Pressure

Difference Between Absolute and Gauge Pressure

Double Block and Bleed Valves Opening or Closing Sequence

Double Block and Bleed Valves Opening or Closing Sequence

Learn More

Oscillating Piston Flow Meters Animation

Oscillating Piston Flow Meters Working Principle

Electronic Devices & Circuits Objective Questions

Electronic Devices & Circuits Quiz – Set 16

Supplied Screen Vibrators Perennial Problems

Supplied Screen Vibrators Perennial Problems

Understanding the Chiller Maintenance - HVAC Tutorials

Understanding the Chiller Maintenance – HVAC Tutorials

PLC Examples for calling functions in SCL

How to Insert Block Calls in SCL Language?

SCADA System

What is SCADA System?

How to Program Sequential Outputs in PLC

Timer-Based Sequential PLC Program with One Button

How to Update the Firmware Version of your PLC

How to Update the Firmware Version of your PLC? – TIA Portal

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?