Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Analytical Process Control Question
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Practical Questions > Analytical Process Control Question

Analytical Process Control Question

Describe in detail the effect this calibration error will have on the performance of the analytical process control system.

Last updated: April 2, 2021 6:09 pm
Editorial Staff
Practical Questions
No Comments
Share
2 Min Read
SHARE

In this process, maple syrup is heated as it passes through a steam heat exchanger, then enters an evaporator where the water boils off. The purpose of this is to raise the sugar concentration of the syrup, making it suitable for use as a food topping.

A level control system (LT, LIC, and LV) maintains constant syrup level inside the evaporator, while an analytical control system (AT, AIR, AC, and AV) monitors the sugar concentration of the syrup and adjusts steam flow to the heat exchanger accordingly.

Steam flow to the heat exchanger

Suppose the syrup analyzer (AT) suffers a sudden calibration problem, causing it to register too low (telling the analytical controller that the sugar concentration of the syrup is less than it actually is).

Describe in detail the effect this calibration error will have on the performance of the analytical control system.

More Questions

  1. What economic effect will this mis-calibration have on the process? In other words, does the process become more or less profitable as a result of this change?
  2. Suppose someone shuts the manual block valve on the steam line just a little bit, so that it is about 80% open instead of 100% open. How will this process change affect the control systems in this process?

Answer

The syrup’s sugar concentration will eventually become excessive as the analytical controller (AC) attempts to maintain setpoint.

Share Your Answers via Comments

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Solenoid Valves Questions & Answers – 4
Liquid Level Switch Control Logic
Problem on Solar Hot Air Collector and Variable Speed Fan
Identify Solenoid Valves Energized or de-energized?
Determine the Problems with Level Transmitter and Gauge
Displacer Level Transmitter Question & Answer
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Purpose of Stop in a Pressure Measuring Instrument
Questions on Resistive Tape Level Sensor
Calculate the Thermocouple Output millivolts
How Manometer Measures Differential Pressure for Different Fluids?
Questions on Allen-Bradley MicroLogix 1000 PLC
Determine the Pressure at Each Port of DP Transmitter
Differential Capacitance Pressure Sensor Circuit
What is the Purpose of Chemical Seals Pressure Transmitter?

Keep Learning

Thermocouple measurement and reference junction temperatures

Thermocouple Measurement and Reference Junction Temperatures

Determine Resistance value of Resistors

Determine Resistance value of Resistors

Inclined Water Manometer

How much Pressure is applied to Inclined Water Manometer?

Draw the Symbols for Liquid Level Measuring Instruments

Draw the Symbols for Liquid Level Measuring Instruments

strain gauge changes as it stretches and shrinks

Why Strain Gauge Resistance Changes as it Stretches and Shrinks?

DP Transmitter Located 10 feet Beneath the Vessel

DP Transmitter Located 10 feet Beneath the Vessel

Calculate Incident Power in Radar Level Measurement

Calculate Incident Power in Radar Level Measurement

Air Compressor Control Circuit has a Problem

Air Compressor Control Circuit Problem

Learn More

PLC based Door Open and Closing System

PLC based Door Open and Closing System

radar-level-sensor-

Non-Contacting Radar Level Transmitter Working Principle

GSD File installation in Simatic Manager

How to Install GSD File in Step 7 PLC using Simatic Manager?

Variable Air Volume Controller in HVAC

What is Variable Air Volume Controller in HVAC?

Operator Interface for SCADA System

Operator Interface for SCADA System

SCADA Interview Questions

SCADA Interview Questions and Answers

Information and Operation Technology

Information Technology and Operation Technology in Industrial Automation

Advantages & Disadvantages of Variable Speed Drives

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?