Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Surface Spectroscopic Techniques
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Multiple Choice Questions > Surface Spectroscopic Techniques

Surface Spectroscopic Techniques

Last updated: November 27, 2021 5:37 pm
Editorial Staff
Multiple Choice Questions
No Comments
Share
4 Min Read
SHARE

Surface Spectroscopic Techniques

1. Surface is usually more than _____ atomic layer deep and is a region of ________ atomic potentials.

a) One, uniform
b) One, non-uniform
b) Two, uniform
d) Two, non-uniform

Answer: b

Explanation: Surface is more than one atomic layer deep and is a region of non-uniform atomic potentials. The outermost layer of atoms is called as surface.

2. Surface analysis can provide information that classic methods like microscopic cannot.

a) True
b) False

Answer: a

Explanation: Surface analysis can provide information that classic methods like microscopic cannot. It is better than reflectivity, adsorption isotherms, etc.

3. In surface spectrometer, which of the following beam is analysed?

a) Reflected beam
b) Absorbed beam
c) Refracted beam
d) Incident beam

Answer: a

Explanation: When a beam is focussed on a surface, one beam enters the material and a second beam is reflected. The reflected beam is analysed.

4. Which of the following is a type of electron spectroscopy?

a) MIKES
b) Auger spectroscopy
c) Secondary ion mass spectroscopy
d) Ion scattering spectroscopy

Answer: b

Explanation: Auger spectroscopy is a type of electron spectroscopy. Electron spectroscopy for chemical analysis is also a type of electron spectroscopy.

5. Surface analysis cannot provide any chemical information directly.

a) True
b) False

Answer: b

Explanation: Surface analysis can provide chemical information. Electron and ion spectroscopic techniques are types of surface analysis.

6. Which of the following is also known as X-ray photoelectron spectroscopy?

a) Auger electron spectroscopy
b) Electron impact spectroscopy
c) Electron spectroscopy for chemical analysis
d) Secondary ion mass spectroscopy

Answer: c

Explanation: Electron spectroscopy for chemical analysis is also known as X-ray photoelectron spectroscopy. It is an effective technique for detecting the elements.

7. Which of the following methods utilizes the emission of low energy electrons in a process?

a) Auger electron spectroscopy
b) Electron impact spectroscopy
c) Electron spectroscopy for chemical analysis
d) Secondary ion mass spectroscopy

Answer: a

Explanation: Auger electron spectroscopy utilizes the emission of low energy electrons in auger process. It is one of the commonly employed techniques.

8. Which of the following is the abbreviation of ESCA?

a) Electron scattering chemical analysis
b) Emission spectroscopy combination analysis
c) Electron spectroscopy for chemical analysis
d) Electron spectrum chemically analysed

Answer: c

Explanation: The abbreviation of ESCA is Electron spectroscopy for chemical analysis. It is a type of electron spectroscopy.

9. Which of the following methods use soft X-rays to eject electrons from inner shell orbitals?

a) Auger electron spectroscopy
b) Electron impact spectroscopy
c) Electron spectroscopy for chemical analysis
d) Secondary ion mass spectroscopy

Answer: c

Explanation: Electron spectroscopy for chemical analysis use soft X-rays to eject electrons from inner shell orbitals. It is a type of electron spectroscopy.

10. Which of the following is the abbreviation of SIMS?

a) Secondary ion mass spectroscopy
b) Spectrum ionization mass spectroscopy
c) Scattering ions mass spectroscopy
d) Spectral ionization mass spectroscopy

Answer: a

Explanation: Secondary ion mass spectroscopy is the abbreviation of SIMS. It is a type of ion spectroscopy.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Pneumatic Systems Objective Questions
Top 1000 Analytical Instrumentation Questions & Answers
Pulse Height Analyzer Questions & Answers
Electrochemical Methods for Oxygen Analysis Questions & Answers
Nyquist Stability Criterion
Electrical Measurements and Instrumentation Objective Questions & Answers
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Pressure Measurement Multiple Choice Questions
PID Controller Multiple Choice Questions
Concept of Stability in Control Systems
Spectrum Analysis of Sampling Process
Difference Equations
Flow Measurement Multiple Choice Questions
Ion Transducers Questions & Answers
Construction of Phase -Trajectories

Keep Learning

Chromatography Questions & Answers

Gas Solid Chromatography Questions & Answers

Liapunov’s Stability Analysis

Liapunov’s Stability Criterion – Part II

Level Measurement Objective Questions

Level and Density Measurement Objective Questions

Bipolar Junction Transistors Questions & Answers

Measurement and Instrumentation Objective Questions – Part 1

Analyzers Questions and Answers

Electron Probe Microanalyser Questions & Answers

Nuclear Magnetic Resonance Spectrometer Questions and Answers

Continuous Wave NMR Spectroscopy Questions & Answers

State Variable Analysis and Design

Concepts of State, State Variables & State Model

Digital Control Systems

Z & S Domain Relationship

Go Deeper

HART Communication

HART Communication Protocol Overview

Sprocket Assembly and Bolting Segments

Bucket elevators Chain and teeth wear Problems

Flow Measurement

Continuous Flow Measurement

How Nuclear Radiation is used to Measure Coke Dust Level?

How Nuclear Radiation is used to Measure Coke Dust Level?

DP-Level-Transmitter-Open-tank-calibration

Open Tank DP Level Transmitter Calibration

Parallel Circuit Parallel Current Calculations

Parallel Circuit Current Calculations

de-energized-to-safe-mode

De-energize to Safe Loop philosophy

Refrigeration Compressor Turbine Not-tripping when needed Trip

Refrigeration Compressor Turbine Not-tripping when needed Trip